• Title/Summary/Keyword: Electric power transmission

Search Result 1,073, Processing Time 0.031 seconds

A study on the investigation and the verification method of the regional restorative transmission (지역별 시송전선로 검토 및 검증방안에 관한 연구)

  • Lee, Nam-Ho;Song, In-Jun;Cho, Kyeong-Bo;Kwak, No-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.187-189
    • /
    • 2003
  • Service restoration following a complete or partial collapse starts with reenergizing a transmission line from black-start generators. Voltage problems can arise from Ferranti effect as unloaded transmission line is reenergized and has to be required to consider it when KPX makes a restorative plan on the massive blackout. This paper presents the investigation of seven regional blackstart lines which are chosen by KPX restorative plan and suggests the verification method for the new designed line according to the system modification.

  • PDF

A STUDY OF INNER COOLING CABLE SYSTEM FOR UNDERGROUND POWER TRANSMISSION LINE (지중 송선선로의 대용량화를 위한 내부냉각 케이블 시스템의 검토)

  • Choi, Chang-Soo;Lee, Kab-Joong;Chugn, Moo-Young
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.615-617
    • /
    • 1993
  • Recently, the demand of electric power has increased remarkably in densely populated cities in Korea. Various method to increase the power transmission capability of underground cable lines has been investigated. In this paper presents the study of inner cool ins cable system for larger power transmission capability. It is also shown that designed inner cooling cable and their system proves more economic than conventional type cables.

  • PDF

Stochastic Integrated Generation and Transmission Planning Incorporating Electric Vehicle Deployment

  • Moon, Guk-Hyun;Kong, Seong-Bae;Joo, Sung-Kwan;Ryu, Heon-Su;Kim, Tae-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • The power industry is currently facing many challenges, due to the new environment created by the introduction of smart grid technologies. In particular, the large-scale deployment of electric vehicles (EVs) may have a significant impact on demand for electricity and, thereby, influence generation and transmission system planning. However, it is difficult to deal with uncertainties in EV charging loads using deterministic planning methods. This paper presents a two-stage stochastic decomposition method with Latin-hyper rectangle sampling (LHRS) to solve the integrated generation and transmission planning problem incorporating EV deployment. The probabilistic distribution of EV charging loads is estimated by Latin-hyper rectangle sampling (LHRS) to enhance the computational performance of the proposed method. Numerical results are presented to show the effectiveness of the proposed method.

The examination of Soyosan substaion's Voltage-system change for improving worn-out facilites (노후설비 개선을 위한 미군전용 66kV 소요산변전소 전압체계 변경 검토)

  • Lee, Seockchang;Kim, Sangjun;Yun, Boohyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.245-246
    • /
    • 2015
  • 주한미군 전력공급 변전소는 남북대치 상태라는 군사적 특수성 때문에 설비의 주기적 유지보수 및 관리가 무엇보다 중요하다. 동두천 주한미군 이전계획에 따라 소요산변전소 설비보강은 중단되었고 전력설비 노후화는 더욱 심화되었다. 이로 인해 변전소 전력설비 안정성이 저하되고, 설비고장 발생시 사회적으로 큰 파장이 예상된다. 본 논문에서는 소요변전소의 노후설비 개선 필요성과 이를 위한 여러 방안을 실제 사례를 들어 설명하고자 한다.

  • PDF

Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement (반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템)

  • Jeon, Jeong Chay;Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

Study on the Distribution of Electromagnetic Force for 154 kV Power Transmission Cable on Dual Underground Lines by Normal and Earth Fault Current (지중 2회선 154 kV 송전케이블의 정상 및 지락고장에 따른 전자기력 분포에 관한 연구)

  • Kim, Hui Min;Kim, So Young;Im, Sang Hyeon;Park, Gwan Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The goal of this study is the size and distribution of the electromagnetic force generated by the current flowing through the second underground line of 154kV power transmission cables by using electromagnetic finite element analysis. So we interpret how mutually electromagnetic force has an effect on the comparable judgement of Trefoil, Duct and Flat, which shows in a numerical arrangement. 154kV OF 1200SQ Cable 1.281km not only is applicable to modeling for underground transmission cable but also examine the effect of line to line, phase to phase and size and direction of the electromagnetic force preparing for the occurrence of normal state and single-phase earth fault, which are arranged in trefoil, duct and flat formation between sections. As showing how the trajectory, and size distribution of the electromagnetic force translate as the arrangement of the cables when a steady-state current and a fault current flows on the underground cables, I hope that when Underground transmission is designed, this data will be useful information.

Measurement and Analysis of Electric and Magnetic Fields near a Transmission Tower (송전철탑 주변에서 전장과 자장의 측정과 분석)

  • Lee, B.H.;Gil, H.J.;Ahn, C.H.;Lee, K.O.;Park, T.W.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1827-1829
    • /
    • 1997
  • In this paper, measurement and analysis of ELF electric and magnetic fields due to a transmission line have been carried out and the power frequency field strength measuring system is designed. In order to evaluate electric and magnetic fields associated with 60 Hz electric power transmission and distribution lines, the actual survey near a transmission tower has been made and analyzed. It may be inferred from these results that the maximum electric and magnetic fields strength in the vicinity of a line tower do not exceed 3.5[kV/m] and 20[${\mu}T$]. The results of the field measurements agree with limits and guidelines recommended by various authorized international institutes.

  • PDF

The first installation of underground transmission line with 345kV XLPE cable in Korea (345kV XLPE 케이블 선로의 준공)

  • Shin, H.D.;Kim, H.J.;Kim, H.J.;Park, K.R.;Song, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1815-1817
    • /
    • 2003
  • Since the first underground transmission line in Korea was installed in 1974, the two types of underground transmission power cables, oil-filled and XLPE, have been applied for underground transmission lines. As the manufacturing technologies of XLPE cable have been improved and the simplicity of installation and maintenance has been focused on, the installations of XLPE cables have been largely increased since the mid 1990's. For the first time, in Korea, the 345kV XLPE cable was installed at Pyungtaek thermal power plant in 2003, February. So, this paper introduces the project profile, the design of cable and its accessory, the cable system design, installation and site test.

  • PDF

Analysis of Electromagnetic Field Around Distribution Line (배전선로 주변에서의 전자계 분포 해석)

  • Kwon, Myung-Rak
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.672-676
    • /
    • 2017
  • Electrical energy is playing an increasingly vital role as the primary energy source in everyday life. With the increase in electric power consumption, power facilities are under an increasing stress and must operate at a high capacity. Consequently, the demand for electric power cables in power transmission and distribution lines is rapidly increasing. Underground distribution lines have been steadily replacing the aboveground lines owing to the increase in electric power demand and the need to increase the supply voltage. In addition to line damage, worker safety is of primary concern in this type of underground infrastructure. In this study, to improve the safety of workers dealing with underground transmission lines, we analyzed the electromagnetic field generated around the distribution line and determined the basic criteria for developing a device that can detect a live underground line.

Probabilistic Reliability Analysis of KEPCO System Using TRELSS

  • Tran Trung Tinh;Kwon Jung-Ji;Choi Jae-Seok;Choo Jin-Boo;Jeon Dong-Hun;Han Kyoeng-Nam;Billinton Roy
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.10-18
    • /
    • 2007
  • The importance of conducting necessary studies on grid reliability evaluation has become increasingly important in recent years due to the number of blackout events occurring throughout the world. Additionally, quantitative evaluation of transmission system reliability is very important in a competitive electricity environment. The reason behind this is that successful operation of an electric power company under a deregulated electricity market depends on transmission system reliability management. The results of many case studies for the Korea Electric Power Cooperation (KEPCO) system using the Transmission Reliability Evaluation for Large-Scale Systems (TRELSS) Version 6.2 are illustrated in this paper. The TRELSS was developed by EPRI and Southern Company Services Inc. This paper presents the reliability analysis of KEPCO system expansion planning by using the TRELSS program.