• Title/Summary/Keyword: Electric power cable

Search Result 486, Processing Time 0.03 seconds

Bridge-edges Mining in Complex Power Optical Cable Network based on Minimum Connected Chain Attenuation Topological Potential

  • Jiang, Wanchang;Liu, Yanhui;Wang, Shengda;Guo, Jian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.3
    • /
    • pp.1030-1050
    • /
    • 2021
  • The edges with "bridge characteristic" play the role of connecting the communication between regions in power optical cable network. To solve the problem of mining edges with "bridge characteristic" in provincial power optical cable network, the complex power optical cable network model is constructed. Firstly, to measure the generated potential energy of all nodes in n-level neighborhood local structure for one edge, the n-level neighborhood local structure topological potential is designed. And the minimum connected chain attenuation is designed to measure the attenuation degree caused by substituted edges. On the basis of that, the minimum connected chain attenuation topological potential based measurement is designed. By using the designed measurement, a bridge-edges mining algorithm is proposed to mine edges with "bridge characteristic". The experiments are conducted on the physical topology of the power optical cable network in Jilin Province. Compared with that of other three typical methods, the network efficiency and connectivity of the proposed method are decreased by 3.58% and 28.79% on average respectively. And the proposed method can not only mine optical cable connection with typical "bridge characteristic" but also can mine optical cables without obvious characteristics of city or voltage, but it have "bridge characteristic" in the topology structure.

The Effect of Different Boding Methods in Under Ground Cable System (지중 케이블 시스템에서 본딩방식의 혼용으로 인한 영향)

  • Kim, J.N.;Ha, C.W.;Lee, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.352-355
    • /
    • 2001
  • 국내에서 CCPU(Cable Covering Protection Unit)의 결선방식은 97년 이전에는 대지간 방식을 취하였고, 97년 이후에는 교락 비접지 방식을 채택하여 적용중이다. 따라서 국내 선로 중에 97년 이전 준공되어 97년 이후에 증설한 선로에서는 CCPU의 연결방식이 대지간 및 교락 비접지 방식이 혼용되어 사용되어 왔다. 본 논문에서는 CCPU의 결선방식이 혼용된 선로에서 문제점을 규명하고 개선안을 제시하였다.

  • PDF

CONSIDERATION OF APPLICATION FOR OPTICAL COMPOSITE POWER CABLE (전력/광 복합 케이블의 적용에 대한 고찰)

  • Kim, J.W.;Kim, H.K.;Ha, B.D.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1547-1549
    • /
    • 1994
  • In recent years, fiberoptic technology is becoming indispensable in establishing communication networks due to its low loss, high capacity and non-inductive properties. In the power industry as well, the technology is being required to cable and facility monitering, and control system. But, duct in the manhole and space in the culvert are required to fiberoptic cable that is separated from power cable. Therefore, some cable makers and R&D has been studying the composite fiber/power cables. This report introduces the outline of ABF system, construction and properties of optical composite power cable that used ABF technology.

  • PDF

Effects of interfacial Microstructure on XLPE Breakdown Strength (가교 폴리 에틸렌의 미세조직 변화가 절연파괴 특성에 미치는 영향)

  • Cho, Dae-Hee;Shim, Sung-Ik;Nam, Jin-Ho;Yeon, Bok-Hee;Lee, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1685-1687
    • /
    • 2004
  • 초고압 케이블의 절연물질로 널리 사용되고 있는 가교 폴리에틸렌의 전기적 특성은 라멜라 결정 조직의 밀도와 라멜라 조직의 성장방향과 밀접한 관련이 있는 것으로 알려지고 있다. 본 연구에서는 반도전 물질에 계면활성제를 첨가하고, 제조 온도를 제어하여 폴리에틸렌의 미세 조직을 변화시킴으로써, 라멜라 조직이 전기적 특성에 미치는 영향을 분석하였다. 전기적 특성은 절연파괴 전압을 측정하였고, TEM 분석을 통하여 폴리에틸렌의 모폴러지 분석을 하였으며, XRD 분석을 통하여 라멜라 조직의 밀도를 분석하였다.

  • PDF

Consideration of cable arrangement for the same phase multi-cable installa (동상다조 포설시 케이블 배치에 대한 고찰)

  • Oh, J.O.;Han, K.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1134-1136
    • /
    • 1998
  • In case of multi-cable for one ph current in the same phase cable may be unba according to cable arrangement in underg system. In this paper, we described the way to ba current in each cable of same phase. This solut to make the impedence of each cable equal caculated the impedence of each cable for all ki cable arrangement in accordance with JCS168D finally found the cable arrangement of impedence.

  • PDF

Reduction of Insulation thickness for EHV XLPE power cable (초고압 XLPE 전력케이블 절연두께 저감화)

  • Lee, Ki-Soo;Choi, Woong;Choi, Young-Hun;Choi, Bong-Nam;Kim, Do-Young;Yun, Duck-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2271-2273
    • /
    • 1999
  • The manufacturing technology of XLPE power cable ( e.g. gas curing, triple common extrusion, clean room, super-clean compound, etc.) had been developed in 1960's and the design parameter of insulation thickness for EHV XLPE power cable at present was determined in 1960's. But, the quality of XLPE power cable has been improved up to now. The re-evaluation of design parameter for insulation thickness reductions is required and so we performed weibull plotting test using model cable. This paper describes the evaluation details of the insulation characteristics according to weibull plotting test.

  • PDF

MV Cable Failure Statistics Analysis and Failure Rate Utilization Method of Prioritization of Diagnosis Targets (지중 배전용케이블 고장통계 분석 및 고장률 활용 진단대상 우선순위 선정방법)

  • Cho, Chong-Eun;Lee, On-You;Kim, Sang-Bong;Kim, Kang-Sik
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.263-268
    • /
    • 2021
  • This paper statistically analyzes the time required for each failure cause and describes a diagnostic method for 159 reports of failure analysis of MV cables that occurred in the distribution system of KEPCO over the past 18 years. In addition, the manufacturer's failure rate compared to 100C-km was calculated using 381 cases of MV cable deterioration failure between 2008 and 2020. It is hoped that this paper will help those in charge of maintaining underground facilities at the business office to use the failure rate to prioritize facility diagnosis.

Degradation of Silicone Rubber Used as Outdoor Insulator Under Accelerated Weathering Condition (자외선 가속열화에 따른 전력용 실리콘 절연재료의 열화평가)

  • Youn, B.H.;Bai, K.M.;Lee, S.J.;Paek, J.H.;Kim, S.W.;Jeon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1906-1908
    • /
    • 2004
  • 본 논문은 옥외용 고분자 절연물로 널리 사용되고 있는 실리콘 고무의 장기 자외선 가속열화에 따른 특성변화를 조사하였다. 이를 위해 전기적인 평가 방법 이외에 각종 화학적 분석기기를 사용하여 보다 정확히 재료의 열화를 판정하고자 하였다. 연구결과, 실리콘 고무는 내후성이 우수하지만, 가속열화가 진행되면서 표면의 전기적 저항률이 높아지고, 전하축적이 용이해지는 표면구조로 변하는 것을 확인하였다. 또한, 재료 내에서 발수성 회복역할을 하는 저분자량 성분이 감소하였고, 열적특성이 변화되는 것을 확인하였다. 이를 통하여, 최근 확산되고 있는 옥외용 고분자 절연물의 성능평가 및 수명예측에 도움이 되고자 하였다.

  • PDF

A Study on Safety Assessment for Ship Sailing under Electric Power Cable (해월(海越)송전선 하부의 선박 통항 안전성 평가에 관한 연구)

  • Kim, Hyun-Jong;Hong, Tae-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.1 s.28
    • /
    • pp.55-60
    • /
    • 2007
  • Many electric power cables span the sea in Korean archipelago. Lots of shipping routes were established between the islands in the same area and ships frequently sail under the cable which cross the seas. Sometimes electric power cables were accidently broken by sailing ships and catastrophic damage of island industry followed thereby. If navigators have detailed knowledge about the height of electric power cable, the ship's sailing condition will be greatly improved. But at the present time, navigators have limited data about the electric power cable. Those are the horizontal distance between pylons, the height of pylons and minimum height of electric power cable. This study introduced the calculating methodology to find out the height of cable at any position between pylons. The ship's tracks were recorded and traffic safety was assessed by statistical method in relation to cable height.

  • PDF

A Study of Properties Eddy Current Sensor for 22.9kv Distribution Insulation Cable (22.9kV 배전선로 절연전선 검출용 와류탐상 센서 특성 연구)

  • Oh, Yong-Cheul;Kim, Tag-Yong;Lee, Kyeong-Seob;Jeong, Han-Seok;Yoo, Jae-Sik;Yang, Jung-Kwon;Lee, Jae-Bong;Lee, Keon-Hang;Kim, Chong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2140_2141
    • /
    • 2009
  • We used the eddy current sensor for a 22.9kV distribution power line insulation cable diagnosis. The insulation cable which is used in the 22.9kV distribution power line is having element wire from 6 to 18. Consequently, currently to ECT applications it has a limit in the distribution power line. We about under producing to apply in pick-up coil forms and the differential total coil form where becomes sum of zero in order to have. From measurement result, partial broken cable was confirmed 500 mV~980 mV changes from normal state.

  • PDF