• Title/Summary/Keyword: Electric measurement

Search Result 1,653, Processing Time 0.03 seconds

A Case Study Of Construction Quality And Measurement Control of High Rock Embankment (고성토 암버력 지반의 시공품질 및 계측관리 사례)

  • Bae, Kyung-Tae;Cha, Kyung-Seob;Park, Yong-Man;Kim, Kang-Kyu;Kim, Hyung-Suk;Yi, Chang-Tok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.891-898
    • /
    • 2009
  • A high rock embankment by means of dynamic compaction has hardly carried out in domestic area. For the successful accomplishment of such a high rock embankment, construction quality and measurement control are conducted. Plate loading tests are carried out to verify the bearing capacity and safety against the long term settlement. In addition, settlement of each layer is measured in order to verify the effect of dynamic compaction and to predict long term settlement.

  • PDF

A Study of Contact Resistance Test Considered with Measurement Uncertainty for Electric Bus Couplers with Battery-Swapping System (측정불확도를 고려한 배터리 교환형 전기버스용 접속기 접촉저항 평가에 관한 연구)

  • Kim, Kwang-Min;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.60-64
    • /
    • 2015
  • Many people think that Electric Vehicles(EVs) is the best method to resolve the problems of running out of fossil fuels. But EVs take long time for charging. So, EVs with battery swapping systems(EVBS) are developed to resolve this problem. Nonetheless, EVBS is not spreaded widely because the method of durability test in couplers is not defined. In this study, the evaluation method of durability test in couplers is defined by some standards and the measurement uncertainty is used to increase the reliability of EV couplers.

Design and Implementation of Intelligent Aircraft Power Measurement System Based on Embedded (지능형 항공기 전력 계측 임베디드 시스템에 설계 및 구현)

  • Choi, Won-Huyck;Jie, Min-Seok
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.664-671
    • /
    • 2013
  • In this paper, in an aircraft power can be measured by wireless AEMS (aircraft electric power measurement monitoring system) system is proposed. AEMS has been design based on current commercialized power measuring systems analysis with improvement and connects it with most talked about item, smart phone and monitoring system. And also adopting real time power measuring system, constitute more practical power measuring system by controlling electricity usage in real time.

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

Measurement of Nonlinear Dielectric Constant (비선형 유전율의 측정)

  • Roh, I.S.;Kang, D.H.;Lee, S.U.;Heo, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1331-1333
    • /
    • 2001
  • In this study a measurement equipment was designed and made for the nonlinear dielectric constants in dielectrics. The determining method of the nonlinear dielectric constants also was proposed. The measurement equipment was consisted of the wave generation part, the high voltage amplifier part, the measurement part and the data acquisition part. In this equipment the measurement control and the data processing could be conducted by computer. In order to determine the nonlinear dielectric constants alternating sign-wave electric fields are applied to dielectrics with different magnitude and the waves of the electric fields and the response from dielectrics are stored in computer memories. The harmonics of dielectric displacement are obtained by the Fourier transformation of these waves. The nonlinear dielectric constants are determined at the relatively low-field region. The experiment for PZT ceramic samples was done by the equipment and the determining method and as the result meaningful data were obtained.

  • PDF

The Measurement of Electromagnetic Wave in Power Cable Tunnel of Underground Utility Tunnel (전력구 내 전자기파에 대한 작업 환경 측정)

  • Kang, Dae Kon;Park, Jai Hak
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Electromagnetic measurements of the power cable tunnel were conducted from August 10 to 20, 2018, in the ${\bigcirc}{\bigcirc}$ city underground utility tunnel. During this period, the average temperature was $31.89^{\circ}C$ and the humidity was 67.56% in power cable tunnel. As a result of the electromagnetic measurement, the highest electric field was 25.3 V/m and the magnetic flux density was $42.6{\mu}T$. The average electric field was 18.56 V/m and the magnetic flux density was $29.32{\mu}T$ in the power cable tunnel. As a result of comparison with the electric equipment technical standard, the electric field in the power cable tunnel was 0.5% of the electric equipment standard and 35.2% of the magnetic flux density. It's similar value that electric field is about robotic vacuum(15.53 V/m), and magnetic flux density is similar value about capsule- type coffee machine ($23.07{\mu}T$). The number of cable lines and the size of the electromagnetic waves were not proportional to each other through comparison of cable lines in the power cable tunnel. It was confirmed that 154 kV, rather than 22.9 kV, could have a greater influence on occupational.

Nondestructive Creep Damage Evaluation of High-Temperature Pipelines by Ultrasonic Attenuation Measurement and Electric Resistance Methods (초음파 감쇠 및 전기저항 측정법에 의한 발전소 고온배관의 크리프손상 평가)

  • Lee, In-Cheol;Kil, Du-Song;Gung, Gye-Jo;Cho, Yong-Sang;Lee, Sang-Guk
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3 s.33
    • /
    • pp.100-107
    • /
    • 1999
  • Due to the high temperature and pressure, the materials of pipeline in power plant are degraded by creep damage. So far, many conventional measurement techniques such as replica method, electric resistance method, adn hardness test method for creep damage have been used. Among them, the replica method has mainly been used for the inspection of components. But this technique is restricted to the applications at the surface of the objects and cannot be used to material inside. In this paper, the measuring methods of evaluation by using ultrasonic attenuation and electric resistance for the creep detection of creep damage in the form of cavities on grain boundaries or intergranular microcracks were carried out. Absolute measuring method of quantitave ultrasonic attenuation technique for 1Cr0.5Mo material degradation was analyzed for determining the creep degradation steps using life prediction formula. As a result of measurement for creep specimens, we founded that the coefficient of utrasonic attenuation was increased as the increase of creep life fracton(${phi}c$) and the decreasing rate of wlwctric resistance was also increased.

  • PDF

The THD measurement of HEP equipment power installed on 8200 series Electric locomotive (8200대 신형 전기기관차 HEP 장치 고조파 왜율 측정)

  • Kim, Dae-Sung;Lee, Kyung-Rac;Ahn, Hong-Goan;Park, Jong-Chun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.488-497
    • /
    • 2010
  • 8100 series Electric locomotive was imported from SIEMENS of Germany on 2001. 8100 series model is modified from BR152 model to be complied with national environment. After 8100 series Electric locomotive carried out main line test for long time, 8200 series Electric locomotive produced in 10 locomotives with improvement and supplement on some parts. the one of supplement is to install the HEP equipment. In paper, about total harmonic distortion of HEP equipment power, it compares the result of combination with the result of actual measurement. It checks whether the measurement meets the specification of design or not. And it describes international standard about total harmonic distortion of supply system.

  • PDF

A Study on the Harmonics and Flickers Measurement of High Speed Electric Train Loads (고속열차 부하의 고조파 및 플리커 측정에 관한 연구)

  • Kim, Kyung-Chul;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.71-77
    • /
    • 2007
  • High speed electric trains have time-varying nonlinear loads causing voltage fluctuations to the power system. A cumulative probablistic approach is the most commonly used method to solve time varying loads. Flicker can be defined as the effect produced on the human visual perception by a changing emission of light lamps subjected to magnitude fluctuations of their supply voltage. This paper provides an in depth analysis on harmonics and flickers measurement of the high speed electric train loads. And the measurement results are evaluated by the IEC 61000-3-6 and IEC 61000-3-7.

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads (전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.35-42
    • /
    • 2006
  • Large steel industries have nonlinear loads including electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.