• 제목/요약/키워드: Electric field calculation

검색결과 192건 처리시간 0.027초

HVAC 가공 송전선로 환경친화설계프로그램 TLCALC (Environmentally Friendly Design Program for HVAC Overhead Transmission Lines)

  • 양광호;주문노;명성호;신구용;이성두;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.67-70
    • /
    • 2005
  • HVAC transmission lines must be designed to satisfy environmental regulations. Therefore it is necessary to pre-evaluate environmental problems for transmission line designer using prediction program. In this study, environment design software, TLCALC 2001 for transmission lines was developed as a comprehensive window program. It has 6 modules that are audible noise, radio noise, television noise, magnetic field, electric field and conductor surface gradient. TLCALC 2001 solved a few problems in use of the existing foreign tools and took several advantages. Experienced designers can get the results of calculation within about 15 minutes. Because the use of TLCALC 2001 is easy and practical, this program will be usefully applied to the environmental friendly design and construction of HVAC transmission lines. In the future, it is expected that public complaints and social environmental cost will be reduced by the use of TLCALC 2001.

  • PDF

HVAC 가공 송전선로 환경친화설계프로그램 개발 (Development of an Environmental Friendly Design Program for HVAC Overhead Transmission Lines)

  • 양광호;주문노;명성호;신구용;이성두;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.469-471
    • /
    • 2002
  • HVAC transmission lines must be designed to satisfy environmental regulations. Therefore it is necessary to pre-evaluate environmental problems for transmission line designer using prediction program. In this study, environment design software, TLCALC 2001 for transmission lines was developed as a comprehensive window program. It has 6 modules that are audible noise, radio noise, television noise, magnetic field, electric field and conductor surface gradient TLCALC 2001 solved a few problems in use of the existing foreign tools and took several advantages. Experienced designers can get the results of calculation within about 15 minutes. Because the use of TLCALC 2001 is easy and practical, this program will be usefully applied to the environmental friendly design and construction of HVAC transmission lines. In the future, it is expected that public complaints and social environmental cost will be reduced by the use of TLCALC 2001.

  • PDF

고속철도의 속도에 따른 아크에 의한 전자파 방사 계산 (Radiated Electromagnetic Field Calculation due to Arc Discharge according to Speed of High Speed Train)

  • 한인수;이태형;조홍식;박춘수;김기환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.98-100
    • /
    • 2011
  • High speed Train Systems are the energy supplied system via the pantograph through which the voltage and the current supplied by the catenary wire flow. The arc discharges generate owing to the contact loss between the catenary and the pantograph, and the electromagnetic fields radiate. There are many different phenomena between the static charges and the moving charges in view of the radiated electromagnetic fields. To calculate the electromagnetic filed about the moving charges, it is necessary to adapt Lorentz transformation. Actually, the particle which moves near the speed of light has the relativisitic phenomena. In addition, it is necessary to predict the electromagnetic field because the radiated electromagnetic field takes effect on the near electronic devices and the human beings. In this paper, we model the arc discharge into the dipole antenna model, adapt Lorentz transformation to the case that the electric railway cars move, and calculate the radiated electromagnetic field. By the calculation, we take the basis upon the electromagnetic prediction, and apply to the future research.

  • PDF

전력선로 근방의 전자파 전자계 계산 (Calculation of the Electromagnetic Wave Ields Near Electric Power Lines)

  • 강대하;이영식;박정은
    • 조명전기설비학회논문지
    • /
    • 제22권6호
    • /
    • pp.79-88
    • /
    • 2008
  • 본 연구에서는 전력선 근방의 전자파 전자계를 쌍극자 안테나 이론에 의해 도출하였으며 수직 전선배열의 3상전력선 근방의 전자계를 정식화함으로써 전자계 계산을 쉽게 할 수 있도록 하였다. 이 계산식들은 송전선로 및 배전선로의 설계시 전자파 전자계의 검토에 활용할 수 있을 것으로 생각된다. 이와 같이 정식화한 각 전자계 성분요소의 식들을 송전선로 모델에 적용하였으며 매틀랩 프로그램을 작성하여 계산하였다. 이 계산 결과를 요약하면 다음과 같다. 전자계의 x성분 $B_x$$E_x$는 무시할 수 있을 정도의 작은 값을 나타내며 대지내의 반사파에 의한 영향만을 반영한다. 수평거리 변화에 대하여 $E_y$$B_z$의 윤곽이 같으며, $B_y$$E_z$의 윤곽도 같다. 이와 같은 사실은 전자파 전계와 자계의 결합요소가 서로 직각으로서 $x{\rightarrow}E_y{\rightarrow}B_z$와 같은 우수계의 전파방향을 갖고 있음을 의미한다. 합성전계 E는 $E_y$요소가 지배적이며 합성자계 B는 $B_z$요소가 지배적이다.

FRACTIONAL FIELD WITH STANDARD FRACTIONAL VECTOR CROSS PRODUCT

  • MANISHA M. KANKAREJ;JAI PRATAP SINGH
    • Journal of applied mathematics & informatics
    • /
    • 제41권4호
    • /
    • pp.811-819
    • /
    • 2023
  • In this research we have used the definition of standard fractional vector cross product to obtain fractional curl and fractional field of a standing wave, a travelling wave, a transverse wave, a vector field in xy plane, a complex vector field and an electric field. Fractional curl and fractional field for a complex order are also discussed. We have supported the study with calculation of impedance at γ = 0, 0 < γ < 1, γ = 1. The formula discussed in this paper are useful for study of polarization, reflection, impedance, boundary conditions where fractional solutions have applications.

관의 형태에 따른 형광램프의 특성 변화 (The Characteristics Change of Fluorescent Lamp According to Tube Shape)

  • 노재엽;이진우
    • 조명전기설비학회논문지
    • /
    • 제14권3호
    • /
    • pp.1-5
    • /
    • 2000
  • 본 논문은 양광주의 전계, 관벅온도, 관벽휘도를 측정하여 관의 형태에 따른 형광램프의 광학적, 전기적 특성 변화를 측정한 것이다. 각 램프의 전계 계산 결과, 그 지수들은 양광주부분에서 거의 변화되지 않았지만 음극 강하의 길이는 크게 변화하였으며, 관벽온도와 휘도는 음극부분에서 크게 변화되었다.

  • PDF

Construction and Application of Experimental Formula for Nonlinear Behavior of Ferroelectric Ceramics Switched by Electric Field at Room Temperature during Temperature Rise

  • Ji, Dae Won;Kim, Sang-Joo
    • 한국세라믹학회지
    • /
    • 제55권1호
    • /
    • pp.67-73
    • /
    • 2018
  • A poled lead zirconate titanate (PZT) cube specimen that is switched by an electric field at room temperature is subject to temperature increase. Changes in polarization and thermal expansion coefficients are measured during temperature rise. The measured data are analyzed to obtain changes in pyroelectric coefficient and strain during temperature change. Empirical formulae are developed using linear or quadratic curve fitting to the data. The nonlinear behavior of the materials during temperature increase is predicted using the developed formulae. It is shown that the calculation results can be compared successfully with the measured values, which proves the accuracy and reliability of the developed formulae for the nonlinear behavior of the materials during temperature changes.

22.9 KV-y 배전선로용 전선보호관 전계강도 비교실험 연구 (A study on the electric field strength of the insulation cover using 22.9 kV-y distribution line)

  • 전영갑;서길수;차기식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1871-1873
    • /
    • 2000
  • There are many electrical accidents between bare wire and line post insulator which is degraded by long time using, causing leakage current on the surface of insulator. In this paper it is presented that the 22.9 Kv-y distribution lines are protected by binding cover which is needed from fog or rainy moisture, surges occurring by switching or lightening pulse. It is analyzed to investigate the unbalanced transfer characteristics and reflection coefficient by using binding cover and non-cover. It was tested the radio interference voltage in the test room and electric field strength by calculation between binding cover and non-cover. In the factory the leakage current causing on the surface of insulator was tested in the state of light load and heavy load.

  • PDF

Organo-lanthanide를 이용한 OLED의 전기 전도 특성 (The Electrical Conduction Characteristics of Organo-lanthanide based OLEDs)

  • 하미영;김소연;문대규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.412-413
    • /
    • 2006
  • The electrical conduction mechanism of ITO / Terbium tris - (1 - phenyl - 3 - methyl - 4 - (tertiarybutyryl) - pyrazol - 5 - one) triphenylphosphine oxide [$(tb-PMP)_3Tb-(Ph_3PO)$]/Mg/Al devices has been investigated. The calculation of electric field in single layer organic layer between cathode and anode shows the uniform distribution for the electron injection barrier of over 1.4 eV. The measured current-voltage curve shows well matching with the calculated curve based on the tunneling injection of electron under the uniform distribution of electric field.

  • PDF

FDTD 방법을 이용한 전자기결합 마이크로스트립 다이폴 배열안테나의 복사패턴 계산 (The radiation pattern calculation of the electromagnetically coupled microstrip dipole array antenna using the FDTD method)

  • 손영수;윤현보
    • 한국통신학회논문지
    • /
    • 제22권7호
    • /
    • pp.1459-1467
    • /
    • 1997
  • The current on the thin planar structure as an element of the transversely fed electromagnetically coupled(EMC) microstrip dipole array antenna is obtained by using the integral forms of the finite difference time domain(FDTD) method. This method was applied to calculating the optimum current distribution (Doplh-Tchebyscheff distribution) of each dipole element on the feed line as a function of their offset positions for the narrow main beam width and the side beam level below -20 dB. The current on each dipole substitutes for the electric and magnetic current densities on the virtual surface of the FDTD calculation to express the far field intensity, the calculation time and the computer memeory can be reduced to about 80% and 1.3 Mbyte, respectively. The calculated radiation patterns are compared to the measured values and these are in good agreement.

  • PDF