• 제목/요약/키워드: Electric decomposition

검색결과 136건 처리시간 0.027초

가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구 (A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis)

  • 김아름;곽병섭;전태현;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

SF6 분해 및 무해화 시스템의 개념 설계 및 운영 결과 (Conceptual Design and Operation Results for SF6 Decomposition and Pollution Control System )

  • 이중원;김미영;안지호;변영환
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.111-118
    • /
    • 2022
  • SF6 is used as an insulating gas because of its excellent electrical insulation properties, non-toxicity, and non-inflammability. On the other hand, the global warming potential of SF6 is 23,900 times higher than that of CO2. The Korea electric power cooperation (KEPCO) is responsible for 80% of the domestic SF6 usage, and approximately 6,000 tons are currently charged in electrical and power facilities. KEPCO will gradually replace the insulating gas with SF6-free gas from 2023. SF6 decomposition facilities are required because more than 60 tons of SF6 will need to be disposed of annually from existing equipment. This study developed a novel decomposition and pollution control system that can process 60 tons of SF6 per year. This facility can decompose more than 97.7% of SF6, with the emissions of hazardous and toxic materials below the legal limit.

Study on Decomposition Gas Characteristics and Condition Diagnosis for Gas-Insulated Transformer by Chemical Analysis

  • Kim, Ah-Reum;Kwak, Byeong Sub;Jun, Tae-Hyun;Park, Hyun-Joo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.447-454
    • /
    • 2020
  • Since SF6 gas was discovered in the early 1900s, it has been widely used as an insulation material for electrical equipment. While various indicators have been developed to diagnose oil-immersed transformers, there are still insufficient indicators for the diagnosis of gas-insulated transformers. When necessary, chemical diagnostic methods can be used for gas-insulated transformers. However, the field suitability and accuracy of those methods for transformer diagnosis have not been verified. In addition, since various types of decomposition gases are generated therein, it is also necessary to establish appropriate analysis methods to cover the variety of gases. In this study, a gas-insulated transformer was diagnosed through the analysis of decomposition gases. Reliability assessments of both simple analysis methods suitable for on-site tests and precise analysis methods for laboratory level tests were performed. Using these methods, a gas analysis was performed for the internal decomposition gases of a 154 kV transformer in operation. In addition, simulated discharge and thermal fault experiments were demonstrated. Each major decomposition gas generation characteristics was identified. The results showed that an approximate diagnosis of the inside of a gas-insulated transformer is possible by analyzing SO2, SOF2, and CO using simple analysis methods on-site. In addition, since there are differences in the types of decomposition gas generation patterns with various solid materials of the internal transformer, a detailed examination should be performed by using precise analysis methods in the laboratory.

Decomposition Properties of Trifluoroiodomethane under Discharges and Interruptions

  • Cai, Fan-Yi;Tan, Dong-Xian;Zhou, Bai-Jie;Xue, Jian;Xiao, Deng-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2385-2391
    • /
    • 2018
  • This paper is devoted to detecting decomposition characteristics of Iodotrifluoromethane ($CF_3I$) under alternating current (AC) discharges or load current interruptions. The decomposition products are measured utilizing chromatography-mass spectroscopy. It is found that less than 1% $CF_3I$ gas decomposed after several interruptions at load current of 200 A or hundred times of AC discharges. However, under interruptions at a current of 400 A, more than 95% $CF_3I$ gas decomposed into carbon tetrafluoride ($CF_4$) and hexafluoroethane ($C_2F_6$). The equilibrium compositions based on Gibbs free energy minimization of $CF_3I$ was calculated to explain the decomposition mechanism.

펜톤 시스템에서의 과산화수소 분해연구 (Decomposition of Hydrogen Peroxide in Fenton Systems)

  • 목영선;조진오;김석태;정우태;강덕원;이병호;김진길
    • 대한환경공학회지
    • /
    • 제29권1호
    • /
    • pp.68-73
    • /
    • 2007
  • 본 연구에서는 철$(Fe^{2+})$이나 구리$(Cu^{2+})$와 같은 전이 금속 이온 촉매에 의한 고농도(1.04-2.55 M) 과산화수소의 분해 거동에 대해 살펴보았다. 과산화수소의 분해에 미치는 금속 이온 농도의 영향이 실험적으로 조사되었고, 이로부터 얻어진 실험 데이터와 이론적 접근을 통해 과산화수소에 대한 분해속도상수가 결정되었다. 과산화수소의 분해 속도식은 과산화수소 농도 관점에서 1차인 것으로 나타났으며, 과산화수소 분해 속도 상수는 금속 이온 초기 농도의 선형 함수로 취급될 수 있었다. 본 연구에서 결정된 분해 속도 상수를 이용하여 계산한 결과는 실험적으로 얻어진 과산화수소 분해 데이터와 잘 일치하였다.

연변방전에 의한 유해물질의 분해제거 (Decomposition of Harmful Materials by SPCP Discharge)

  • 우인성;황명환
    • 한국전기전자재료학회논문지
    • /
    • 제11권11호
    • /
    • pp.1043-1048
    • /
    • 1998
  • The decomposition performance of the Surface induced Plasma Chemical Processing(SPCP) for benzene, toluene, xylene and $NO_2$ were experimentally examined. Discharge exciting frequency range was 5kHz and 10kHz, and low frequency discharge requires high voltage to inject high electric power in gas and to decompose contaminants. The decomposition rate of dioxide nitrogen for 5kHz power in gas and to decompose contaminants. The decomposition rate of dioxide nitrogen for 5kHz power supply is only 85%, but it’s rate for 10kHz power supply is very high, more than 96% when peak voltage is 12kv. Aromatic hydrocarbon vapor of up to 1000ppm is almost throughly decomposed at the flow rate of 1000$\ell$/min or lower rate under the discharge with electric power of several hundred watts. High decomposition rate is shown in every case, that is, for SPCP reactor is necessary to obtain the decomposition rate of more than 80~98%. The decomposition rate of benzene, toluene and xylene were 90~98% and dioxide nitrogen was 45~96%.

  • PDF

알루미늄 전극의 용출에 따른 해성점토의 개량에 관한 실험적 연구 (A Experimental Study on Improvement of Marine Clay through the Electrolytic Leaching Effect in Aluminum Electrode)

  • 김종윤;윤명석;정승용;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1173-1180
    • /
    • 2006
  • In this study, aluminum electrodes were put in marine clay which was taken from the south coast in Korea to increase the undrained shear strength by inducing the densification and cementation between clay particles and precipitates which were developed by electric decomposition in an electrode. To raise the cementation rate and reduce treatment time, high electric current (2.5A) was applied in each electrode at a semi-pilot scale soil box with marine clay. After the tests, the undrained shear strength was measured at designated points using a static cone penetration test device and sampling was conducted simultaneously in order to measure water content, pH and electric conductivity which would be the key for configuring the cementation effects indirectly. In the results of electric decomposition in aluminum electrode, the measured shear strength was increased considerably compared to the initial shear strength because of the cementation effect between iron ions and soil particles.

  • PDF

영역분할법 (domain decomposition)과 TLM법을 이용한 회전기의 비선형 유한 요소 해석 (A Novel Finite Element Technique for analyzing Saturated Rotating Machines Using the Domain Decomposition and TLM Method)

  • 주현우;임창환;이창환;김홍규;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.623-625
    • /
    • 2000
  • For the finite element analysis of highly saturated rotating machines involving rotation of a rotor such as dynamic analysis. cogging torque analysis and etc, so much time is needed because a new system matrix equation should be solved for each iteration and time step. It is proved in this paper that. in linear systems. the computational time can be greatly reduced by using the domain decomposition method (DDM). In nonlinear systems. however. this advantage vanishes because the stiffness matrix changes at each iteration especially when using the Newton-Raphson (NR) method. The transmission line modeling (TLM) method resolves this problem because in TLM method the stiffness matrix does not change throughout the entire analysis. In this paper, a new technique for FEA of rotating machines including rotation of rotor and non-linearity is proposed. This method is applied to a test problem. and compared with the conventional method.

  • PDF

Influence Regularity of Aluminum, Copper and Stainless-steel on SF6 PD Decomposition Characteristics Components

  • Zeng, Fuping;Luo, Jing;Tang, Ju;Zhou, Qian;Yao, Qiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.295-301
    • /
    • 2017
  • $SF_6$ decomposition products can be used to detect partial discharge (PD), but the metal materials in a PD area can significantly affect $SF_6$ decomposition characteristics. Disregarding the effect of metal materials on such characteristics inevitably result in certain errors when using them to diagnose the internal insulation faults of gas-insulated switchgears. This paper investigates the influence regularity on the main stable decomposition components of $SF_6$ (namely $SO_2F_2$ and $SOF_2$) of the commonly metal materials uesd in GIS, such as aluminum (Al), copper (Cu) and stainless steel (SS). Firstly, an experimental platform is constructed to simulate $SF_6$ decomposition under a PD area, and the influence regularities of Al, Cu and SS on the concentration, formation rate and saturation time of $SO_2F_2$ and $SOF_2$ are obtained. Secondly, the influence mechanism of Al, Cu and SS are preliminary explored combined with the chemical activity of the metal materials.

워터젯 플라즈마 스크러버 사불화탄소 분해 특성 (Decomposition Characteristics of Tetrafluoromethane Using a Waterjet Plasma Scrubber)

  • 임문섭;전영남
    • 한국기후변화학회지
    • /
    • 제8권1호
    • /
    • pp.63-71
    • /
    • 2017
  • It is recognized that tetrafluoromethane ($CF_4$) has a great influence on global warming. The $CF_4$ is known to have a large impact on climate change due to its large global warming index. In this study, a waterjet plasma scrubber (WPS) was designed and manufactured for the $CF_4$ decomposition. The WPS is a novel technology which is combined a gliding arc plasma and water injection at the center of the plasma discharge. This can give an innovative way for $CF_4$ decomposition by achieving larger plasma columnand generating OH radicals. A performance analysis was achieved for the design factors such as waterjet flow rate, total gas flow rate, consumption electric power, and electrode gap. The highest $CF_4$ decomposition and energy efficiencies were 64.8% and 6.43 g/kWh, respectively; Optimal operating conditions were 20 mL/min of waterjet flow rate, 200 L/min total gas flow rate, 5.3 kW consumption electric power, and 4.4 mm electrode gap. As for the 2 stage reactor of the WPS, the $CF_4$ decomposition efficiency improved as the 85.3% while the energy efficiency decreased as the 5.57 g/kWh.