• Title/Summary/Keyword: Electric Shock

Search Result 407, Processing Time 0.022 seconds

The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current (인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석)

  • Kim, Jae-Hyun;Lim, Young-Bea;Lee, Sang-Ick;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement (반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템)

  • Jeon, Jeong Chay;Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

Experimental investigation of electric currents flowing through human body in electirc shock (전기충격시인체에 흐르는 전류의 실험적 고찰)

  • 김완배;안광윤;윤태원
    • 전기의세계
    • /
    • v.29 no.1
    • /
    • pp.21-27
    • /
    • 1980
  • The effect of electric shock on human body is enormousness, which leads to warmth, tingling, and even death. The mean values of perception currents obtained on 91 men and 39 women are about 0.77(mA) for men and 0.57(mA) for women. The mean value for women is approximately seven tenths that of men. An individual can tolerate, with no adverse effects, repeated exposure to the reactions associated with currents of his let-go level, and the mean value of let-go currents obtained from 27 normal men is 6.29(mA). Lethal currents flowing human body is very dangerous even for a short time. So, it is necessary to have recourse to animal experiments ot determine lethal current for human. An analysis of experimental data indicates that body weight and shock duration are important factors in determining the lethal current. It is suggested that the relationship between current and shock duration is given by I=K/.root.T, and lethal current is proportional to body weight, where I is the current in milliampere, and T is the time in seconds.

  • PDF

ER Smart Structures for Shock Wave Reduction (충격파 저감을 위한 ER 지능구조물)

  • 김재환;김지선;최승복;김경수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.9
    • /
    • pp.679-687
    • /
    • 2003
  • Shock wave reduction in electrorheological(ER) smart structures is studied. ER insert is a composite structure comprising two elastic outer layers between which is sandwiched layer of ER fluid. When a voltage is applied across the outer layers. the shear modulus and the loss factor of the ER fluid are enabled, and thus the dynamic properties of the composite structure is altered. For the shock wave reduction in a hull mount of a submerged structure, ER inserts are made on the hull mount structure. To investigate the ER insert shape. many types of ER insert pattern are considered. Modal test of ER insert structures is performed to obtain the mode shapes, natural frequencies and the acceleration transmissibility. The acceleration transmissibility is reduced at such a frequency region when an electric field is applied. It is observed that the natural frequencies and mode shapes can be tunable by applying electric field. The ER-inserted hull mount is installed in an integrated system and the overall performance of shock wave reduction is tested. The possibility of shock wave reduction in the hull mount is demonstrated.

Manufacturing and Characteristics Analysis of a Testing Device for the Evaluation of a Distribution Board Management System (분전반 관리시스템 평가를 위한 시험 장치의 제작 및 특성 분석)

  • Ko, Wan Su;Lee, Byung Seol;Choi, Chung Seog
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.31-36
    • /
    • 2019
  • This study made a testing device to evaluate the distribution board management system. Power was supplied to the testing device using a loading-back method and the voltage applied to it was 440 V at the same turn ratio. When the human body electric shock current is 30 mA, the breaking time is set to be less than 240 ms while 30~45 mA current is flowing. The test result shows that in the case of the R-phase it was measured to be 5.19 Hz (193 ms). And the S-phase and T-phase were perfectly cut off at 5.39 Hz (186 ms) and 5.71 Hz (175 ms), respectively. When the human body electric shock current is 60mA, the breaking time is set to be less than 120 ms while 45~75 mA current is flowing. The test result shows that the R-phase, S-phase, and T-phase were accurately cut off at 8.39 Hz (11 ms), 8.87Hz (113 ms) and 9.69 Hz (103 ms), respectively. When the human body electric shock current is 90 mA, the breaking time is set to be less than 48 ms while 75 mA current is flowing. The test result shows that the R-phase, S-phase, and T-phase were accurately cut off at 19.8 Hz (50.4 ms), 16.9 Hz (59.2 ms), and 17.9 Hz (56.0 ms), respectively. That is, the developed testing device satisfied all the requirements of the distribution board evaluation criteria, and it becomes available for the performance evaluation of the distribution board management system.

Study on Crack Resistance Improvement of Epoxy Insulation (Epoxy 절연물의 내크랙성 향상에 관한 연구)

  • Ha, Young-Kil;Kim, Su-Yon;Lee, Sang-Jin;Kim, Young-Seong;Park, Wan-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1581-1583
    • /
    • 1999
  • Epoxy Compound has been used as insulation material in cable accessories. During the applying voltage to cable, heat shock is induced to accessory by the temperature difference between atmosphere and conductor. In this study, crack resistance, thermal and mechanical properties were evaluated about conventional epoxy compound and rubber toughened epoxy compound. Because rubber absorbs the stress caused by heat shock, crack resistance of rubber toughened epoxy compound is high. In the case of low thermal expansion coefficient, the compound shows high crack resistance because of low volumetric change.

  • PDF

DC Leakage Current Properties Analysis of the LED Lamps of Road and Landscape Lighting (LED 가로등 및 경관조명의 직류 누전 특성 분석)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.885-891
    • /
    • 2011
  • In this paper, we studied dc leakage current properties analysis of LED lamps of road and landscape lighting when leakage current appeared in dc power line. Generally, converter of LED lighting is divides to insulated type and non-insulated type according to components. When electric leakage happened in AC power line, earth leakage breaker(ELB) senses leakage current and interrupts electric circuit. In dc power source, We need experimental verification about dc electric leakage for electricity safety. In normal wiring conditions and in the water, in case of using insulated type of converter, dc leakage current did not occur. However, in case of using non-insulated type of converter, dc leakage current occurred and passed through into the ground. We found that there is a hazard of electric shock by dc leakage current. We expect that the results of these studies would be helpful for electrical safety of LED lamps for road and landscape lighting.

A Speed Control for the Reduction of the Shift Shocks in Electric Vehicles with a Two-Speed AMT

  • Kim, Young-Ki;Kim, Hag-Wone;Lee, In-Seok;Park, Sung-Min;Mok, Hyung-Soo
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1355-1366
    • /
    • 2016
  • In the present paper, a speed control algorithm with fast response characteristics is proposed to reduce the shift shock of medium/large-sized electric vehicles equipped with a two-speed AMT. Shift shocks, which are closely related with to the vehicles' ride comfort, occur due to the difference between the speed of the motor shaft and the load shaft when the gear is engaged. The proposed speed control method for shift shock reduction can quickly synchronize speeds occurring due to differences in the gear ratios during speed shifts in AMT systems by speed command feed-forward compensation and a state feedback controller. As a result, efficient shift results without any shift shock can be obtained. The proposed speed control method was applied to a 9 m- long medium- sized electric bus to demonstrate the validity through a simulated analysis and experiments.

The Field Situation Analysis of Street Lamp Which is Established in The Urban (도심에 설치된 가로등설비의 현장실태 분석)

  • 한운기;한기붕;길형준;최충석
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.117-122
    • /
    • 2003
  • Street light facilities, which are easily accessible, can be in danger of electric shock when water percolates the facilities especially in summer. In case deteriorated facilities are not checked regularly, they can cause accidents such as electric shock. We should consider regional characteristics to prevent this kind of accidents. In this paper, we analyzed the problems according to the facilities through the research on the actual conditions. We also analyzed the facilities by region and the standards by the conditions.

  • PDF

Measurement and Estimation of Dynamic Resistance of the Human Body Using Body Current at Low-Voltage Levels (저전압에서의 통전전류를 이용한 인체의 동저항 측정 및 예측)

  • 김두현;강동규;김상철
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • The severity of electric shock is entirely dependent on body resistance. When the human body becomes a part of electric circuit, the body resistance is given as a function of shock scenario. Factors which consist of applied voltage, shock duration, body current path and contact area, etc.. The body resistance is defined as the voltage applied to subjects divided by the body current. To secure safety of the subjects, the experiment is conducted on 10 subjects, the body current is limited to 4mA. And only three factors under many shock scenario conditions are used to determine the body resistance. The three factors are the applied voltage, the current pathway and the contact area. The object of this work is to estimate the dynamic resistance of the human body as a function of applied voltage using the body current at low-voltage levels. The data of the body current at low-voltage levels are extrapolated to high-voltage levels using two analytic functions with specified constants calculated by numerical method. Also we can provide permissible body voltage for various copper electrodes on the basis of the data determined with the dynamic resistance and the body current.

  • PDF