• Title/Summary/Keyword: Electric Resistance

Search Result 1,437, Processing Time 0.032 seconds

A Study on Electric Resistance Heated Surface Friction Spot Welding Process of Overlapped Copper Sheets (중첩된 구리 판재의 전기저항가열 표면마찰 점용접(RSFSW)에 관한 연구)

  • Sun, Xiao-Guang;Jin, In-Tai
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • Copper sheets has been used widely in electric and electron industry fields because they have good electric and heat conduction property of the material. And, in order to bond copper material, a kind of soldering process is generally used. But, because it is difficult to bond by soldering between overlapped thin copper sheets, so, another kind of brazing bonding process can be used in that case. But, because the brazing process needs wide bonding area, it needs heat treatment process in electric furnace. Generally, for spot welding of sheets, a conventional electric Resistance Spot Welding process(RSW) has been used, it has welding characteristics using contact resistance heating induced by electric current flow between sheets. But, because copper sheets has the low electric resistance, it is difficult to weld by electric resistance spot welding. So, in this study, an electric Resistance heated Surface Friction Spot Welding process(RSFSW) is suggested and is testified for the spot welding ability of thin copper sheets. It is known from the experimental results and simulation that the suggested spot welding process will be able to improve the spot welding ability of copper sheets by the combined three kinds of heating generated by surface friction by rotating pin, and conducted from heated steel electrode, and generated by contact resistance of electricity.

Estimation of Grounding Resistance by Correlation Analysing Change Factors of Soil Resistivity and Grounding Resistance (토양환경 변화와 접지저항의 상관관계 분석을 통한 접지 저항값 예측 연구)

  • Choi, Sun-Kyu;Lee, Kyu-Young;Moon, Young-Ho;Shim, Keon-Bo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2020
  • The purpose of this paper is to improve the grounding point measurement method for the maintenance of the earth resistance of the distribution line. This study defines the correlation among humidity of the soil, the earth resistivity and the grounding resistance. Based on the results of the study, the grounding resistance value measurement should be limited to the location where the earth resistivity change is large, and the measurement time and cost can be greatly reduced.

Measuring method of electric resistance using thermoelectric properties of module (열전모듈의 발전특성을 이용한 전기저항 변화 측정)

  • Woo, Byung-Chul;Lee, Hee-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1332-1334
    • /
    • 2002
  • Thermoelectric generation is the direct energy conversion method from heat th electric power. The conversion method is a very useful utilization of waste energy because of its possibility using a thermal energy below $150^{\circ}C$ This research objective is th establish the thermoelectric technology on a optimum system design method and efficiency, and cost effective thermoelectric element in order to extract the maximum electric power from a wasted hot water. This paper is considered in manufacturing a thermoelectric generator and measuring of electric resistance of module a thermoelectric modules. It was found that the electric resistance of thermoelectric modules was defined as a temperature functions. The relationship between electric resistance and temperature characteristics can be a analogized as function of electric current.

  • PDF

Investigation of Abnormal Wear of Jig in Electric Resistance Welding (전기저항 용접 시 발생하는 지그의 비정상 마모현상 원인 분석)

  • Kim, Sun-Ho;Cho, Hang-Deuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • This paper presents an investigation of abnormal wear of a contact jig between a nail and a nail fixture in electric resistance welding. To perform an analysis on the abnormal wear phenomenon, several methods are provided. Based on the theory of electric resistance welding, are analyzed. Using microscopic analysis, surface craters are observed. In the measurement of the electric current flow in the nail fixture, the current flow distribution is measured. From several analyses, the cause of abnormal wear in the contact jig is measured using the electric discharge of high current density at the inflow point of the electric supply to the nail fixture. An alternative shape for normal wear is proposed.

Effects of Soil Environments by Location on the Cambium Electric Resistance of Pinus thunbergii in Urban Park and Open Space (도시공원녹지의 입지별 토양특성이 곰솔의 형성층 전기저항에 미치는 영향)

  • Park, Seung-Burm;Nam, Jung-Chil;Kim, Seok-Kyu
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.6
    • /
    • pp.13-22
    • /
    • 2006
  • The purpose of this study is to propose rational methods in order to maintain vegetation condition and soil environment based on the analysis of tree growth in relation to the soil environment, which is one of the most significant environmental factors on vegetation condition in urban parks and open spaces. The result of the study can be described as below;The soil on every study site had strong acidity. In particular, study sites around industrial district and central business district showed extreme soil acidity. Therefore, soil management system is needed in urban parks and green spaces around those areas. Among Cambium Electric Resistance classified by locations of urban parks and open spaces, one in the costal area was the lowest. The Cambium Electric Resistance in the industrial area was the highest. Therefore, soil condition and locational environment in the industrial area are highly related to the Cambium Electric Resistance. Among the factors, which affect Cambium Electric Resistance in different locations, inorganic content was found to be the main factor in all of the study sites. Inorganic content was an important factor to the Cambium Electric Resistance in study sites located in industrial and central business districts. In the study sites located in costal area, Soil acidity was found to be other important factors that affect Cambium Electric Resistance. To improve the soil acidity, soil buffering ability should be improved from activating microorganisms in the soil by using lime and organic material, Since it takes a long time to make a change in the soil structure, well planed maintenance system is required by mid-term or long-term plans.

Electric Resistance Surface Friction Spot Welding Process of AZ31 Mg Alloy Sheets by Using Rotating Dies (회전금형을 사용하는 AZ31 마그네슘 합금판재의 전기저항 표면마찰 스폿용접)

  • Kim, T.H.;SUN, XIAOGUANG;Jin, I.T.
    • Transactions of Materials Processing
    • /
    • v.27 no.3
    • /
    • pp.145-153
    • /
    • 2018
  • Magnesium material could be widely used in the automotive industry because of its high strength to weight ratio, but the electric resistance spot welding process of magnesium sheets is difficult because of its low electric resistance and high thermal conduction and thermal expansion. For this reason, an electric resistance surface friction spot welding process using rotating dies is suggested for the spot welding of magnesium metal sheets. This welding method can be characterized by three heating methods: (1) electric resistance heating on contacted surface, (2) surface friction heating by rotating dies, and (3) thermal conduction heating from heated steel electrodes, for the fusion of metal at the interfacial zone between the two magnesium sheets. This welding process also has variables to explore, such as welding currents, diameters of the steel electrode, and rotating dies. It was found that the welding strength could reach industrial requirements by applying a welding current of 11.0kA, with steel electrodes of 12mm diameter, with rotating dies of 4.4 mm diameter, under the condition of a revolution speed of 1200rpm of rotating dies, for the surface friction spot welding process of AZ31 magnesium alloy sheets of 1.4mm thickness.

Effect of Electric Frequency on the Partial Discharge Resistance of Epoxy Systems with Two Diluents

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.317-320
    • /
    • 2013
  • Partial discharge resistance for the epoxy systems with two diluents was investigated in the rod-plane electrodes arrangement, and the effect of electric frequency on the partial discharge resistance was also studied. Diglycidyl ether of bisphenol A (DGEBA) type epoxy was used as a base resin, and 1,4-butanediol diglycidyl ether (BDGE) or polyglycol (PG) as a reactive diluent was introduced to the DGEBA system, in order to decrease the viscosity of the DGEBA epoxy system. BDGE was acted as a chain extender, and PG acted as a flexibilizer, after the curing reaction. To measure the partial discharge resistance, 5 kV alternating current (ac) with three different frequencies (60, 500 and 1,000 Hz) was applied to the specimen in a rod-plane electrode arrangement, at $30^{\circ}C$. PG had a good effect, while BDGE had a bad effect on the partial discharge resistance of the DGEBA system, regardless of the electric frequency.

Lifetime-Temperature Rise Model for the Evaluation of Degradation in Electric Connections/Contacts (전기적 접속/접촉부 열화 평가를 위한 수명 온도상승 모델)

  • Kim, Jeong-Tae;Kim, Nam-Jun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this paper, 'lifetime-temperature rise model' based on the 'lifetime-resistance model' is theoretically Proposed, in order to find out the evaluation method of degradation and the residual lifetime by use of infrared image camera for electric connections/contacts. Two assumptions have been builded up for the 'lifetime-temperature rise model': one is associated with the linear relationship between the temperature ism ΔK and contact resistance, and the other the functional relationship between the temperature of electric connections/contacts and the operating time presenting in the 'lifetime-resistance model'. To prove the proposed model, experiments have been performed for various electric connections/contacts. From the experimental results, measured values were quite similar to the calculated values, which proved the above-mentioned two assumptions. Therefore, by use of 'lifetime-temperature rise model', it is possible to estimate the trend of degradation and the residual lifetime for electric connections/contacts through the temperature measurements .

Characteristics of Electric Resistance Heated Surface Friction Spot Welding Process of Copper and Aluminum Dissimilar Metal Sheets (구리와 알루미늄 이종금속 판재간의 전기저항가열 표면마찰 스폿용접 특성)

  • Sun, Xiao-Guang;Jin, In-Tai
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.8
    • /
    • pp.99-109
    • /
    • 2022
  • In this study, an electric resistance-heated surface friction spot-welding process was proposed and tested for the spot-welding ability of copper and aluminum dissimilar metal sheets using electric resistance heating and surface friction heating. This process has welding variables, such as the current value, energizing cycles, rotational speed, and friction time. The current value and energizing cycle can affect the resistance heat, and the rotational speed of the rotating pin and friction time influence frictional heat generation. Resistance heating before friction heating has a preheating effect on the Cu-Al contact interface and a positive effect on preventing friction heat loss during the friction stage. However, because resistance preheating can soften the copper sheet and affect the contact stress and friction coefficient, it has difficulties that may adversely affect frictional heat generation. Therefore, the optimal combination of welding variables should be determined through simulations and experiments of the spot-welding process to determine the effects of electric resistance preheating on the suggested process. Through this procedure, it is known that the proposed spot-welding process can improve the welding quality during the spot welding of Cu-Al sheets.

The Study on Tree Vigor of Damaged Forest by Thecodiplosis japonensis Uchida et Inouye (솔잎혹파리 피해임지의 수세변동에 관한 연구)

  • Lee, Chan-Yong;Chae, Hee-Mun;Kim, Jong-Kuk
    • Journal of Forest and Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.34-41
    • /
    • 2000
  • This study investigated tree vigor of damaged forest by Thecodiplosis japonensis Uchida et Inouye. In damaged forest by pine gall midge, the investigation result of damaged rate section (severe, moderate, light) indicated that severe stand showed higher value of electric resistance ($k{\Omega}$) than that of light stand, the investigation result of tree density section(crowed, middle, little) indicated that crowed stand showed higher value of electric resistance than that of little stand (the value of electric resistance at which low reading show high vigor tree and high reading low vigor tree). The crown width and DBH (diameter of breast height) of external factors showed lower value of electric resistance than that of small size. The results of comparative between Crown area and value of electric resistance in each stand were $13.4m^2$ in severe stand, $10.9m^2$ in moderate stand and $7.9m^2$ in light stand. Therefore, the tree which have big crown showed low value of electric resistance (below $15k{\Omega}$)that has high possible of survial.

  • PDF