• 제목/요약/키워드: Electric Energy Management System

검색결과 318건 처리시간 0.032초

ETA를 이용한 에너지저장시스템의 위험성 평가 (Risk Assessment of Energy Storage System using Event Tree Analysis)

  • 김두현;김성철;김의식;박영호
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.34-41
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on six items of ESS: the whole system, battery, BMS, PCS, ESS and cable. To achieve that, ESS work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew initiation events (IE) and end states (ES). ETA is applied to the main functions of each item, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events ; loss of grid electricity of ESS, loss of battery electricity(DC) of battery, impairment of electric function of BMS, loss of grid electricity(AC) of PCS, loss of data of EMS, Mechanical damage of cable, event sequence analysis conducted on the basis of event trees. If the suggested IEs and ESs are applied on the basis of ESS event cases, it is expected to prevent the same kinds of accident and operate ESS safely.

중수승급기 성능관리 프로그램 개발 (Computer Program Development for D$_2$O Upgrader Performance Management)

  • Ahn, Do-Hee;Kim, Kwang-Rag;Chung, Hong-Suck;Kim, Yong-Eak;Jeong, Ill-Seok;Hon, Sung-Yull;Ko, Jae-Wook
    • Nuclear Engineering and Technology
    • /
    • 제22권1호
    • /
    • pp.1-11
    • /
    • 1990
  • 중수는 중수형 원자로의 감속재 및 냉각재로 사용되고 있으며 그 가격이 고가이기 때문에 일단 계통내에서 사용된 후 농도가 낮아진 저등급 중수는 중수승급기를 통해 99.8% 이상으로 농축 재생되어 중수로로 재주입되고 있다. 본 연구에서는 중수승급기의 공정을 면밀히 검토하였고 정상상태의 중수증류공정의 해석을 위하여 이론적인 모델을 제시하였으며 변수들간의 관계식을 설정하였다. 그리고 이 비선형 관계식을 단계적으로 처리하는 알고리즘의 전산 프로그램 UPGR을 개발하였다. 전산코드의 결과는 실제 운전 데이타와 잘 일치하였다. 월성 1호기에서 이를 이용한 운전지침의 제시, 운전효율의 평가, 성능평가 및 성능관리를 수행함으로써 중수승급기의 효율적인 운전에 기여하고 있다.

  • PDF

규제 완화된 전력시스템의 전원개발계획 방법론 고찰 (Analysis of Generation Expansion Planning Methodology in Deregulated Power Systems)

  • 조형준;황성욱;장승찬;김발호;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1101-1103
    • /
    • 1999
  • Deregulation and restructuring of electric industry change the fundamental nature of electric business which will be coordinated by the evolved market structures such as spot market with pool and bilateral transaction structure, forward market and future market. Introduction of competition can significantly change the system operation in near-terms as well as long-run generation expansion planning Previous centralized planning by monopoly utilities which was guided for the public service purpose will be replaced by decentralized investments plan by individual generation companies in response to commercial incentives. This paper reviews WASP model as a centralized planning tool and presents a methodological analysis of generation expansion planning in deregulated power systems. It stresses how affects the process of planning new generation investments by the introduction of competition and how maintains proper fuel mix and continuously sustains system reliability under deregulated environments.

  • PDF

2.3 kW급 전기자동차 배터리팩용 냉각 장치의 열전달 특성에 관한 해석적 연구 (Numerical Analysis of Heat Transfer Characteristics of Cooling System for 2.3 kW EV Battery Pack)

  • 성동민;박용석;성홍석;서정세
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.44-49
    • /
    • 2022
  • The improvement in the battery performance and life using a battery thermal management system directly affects the improvement in the performance, life, and energy efficiency of electric vehicles. Therefore, this study numerically analyzed the heat exchange processes between the coolant inside the cooling plate channel and the heat generated by the battery. The cooling performance was analyzed based on the average temperature, temperature uniformity, and the maximum and minimum temperature differences of the battery. A performance difference existed depending on the coolant inlet temperature but showed the same tendency of cooling performance according to the shape of each plate's channel. Type 1 showed the best results in terms of battery temperature uniformity, which is the most important measure of battery performance; Type 2 showed the best results in terms of the average temperature of the battery; and Type 3 showed the best results in terms of the maximum and minimum temperature differences of the battery compared with that of the other cooling plates.

Management of the energy harvesting for MEMS/NEMS via newmark current method

  • Shang, Kun;Shan, Huafeng;Alkhalaf, Salem;Marzouki, Riadh;Khadimallah, Mohamed Amine
    • Advances in nano research
    • /
    • 제12권6호
    • /
    • pp.567-581
    • /
    • 2022
  • The free and forced vibration in addition to electric energy harvesting of a piezoelectric disk resting on two-parameter foundation modeled by modified couple stress as well as Kirchhoff plate theory is probed. The governing equations and boundary conditions are obtained using Hamilton's principle. Then, the free and forced vibration are solved using numerical solutions, generalized differential quadrature method (GDQM) and Newmark-beta method. The forced vibration is resulted from a base excitation load. Also, the possible voltage which can be harvested from this system is obtained using generalized integral quadrature method. The validity of the formulation and solution procedure is confirmed using a compassion study. The impact of parameters such as length effect, inner to outer radius ratio, and foundations parameters on the free and forced vibration as well as energy harvesting is investigated in detail. This paper can be a basis for future studies in the area of piezoelectric harvesters in small scales.

ICCP를 사용한 전력센터간의 통신 프로토콜 구현 (Implementation of Communication Protocol between Control Centers using ICCP)

  • 장경수;장병욱;한경덕;신동렬
    • 한국정보처리학회논문지
    • /
    • 제7권12호
    • /
    • pp.3910-3922
    • /
    • 2000
  • 현재의 전력시스템은 컴퓨터와 통신기술의 발전으로 분산시스템인 EMS(Energy Menagement System)/SCADA(Super-vision Control and Data Acquisition) 형태로 운영되어 전력의 생산, 전송 그리고 분배가 효과적으로 이루어지고 있다. 그러나 각 시스템은 언어, 운영체제 그리고, 통신프로토콜이 서로 다른 제품으로 구성되어 시스템간에 데이터를 교환하는데 많은 어려움이 따르고 있다. 이러한 문제를 해결하기 위해서는 미국 전력연구소는 전력제어센터간의 통신을 담당하는 ICCP(Inter-Control Center Protocol)라는 새로운 형태의 통신규약을 발표하였다. ICCP는 자동화용 표준 통신규약인 MMS(Manufacturing Message Specification)를 응용계층의 하부 규약으로 지정함으로써 서로 다른 기종의 제어센터간의 원활한 통신을 지원한다. 본 논문은 ICCP의 특징과 MMS와 ICCP가 어떻게 상호 연관되는가를 밝힌다. ICCP에서 이용하는 MMS 라이브러리(library)의 86개의 서비스 중 일부 서비스를 구현한 후 이것을 이용하여 TCP/IP 환경 하에서 ICCP의 기본이면서 핵심적인 기능을 구현한다. 그 다음, ICCP 프로토콜을 이용하여 EMS간의 통신을 모델링하고, 전력센터간의 실제 데이터 교환을 윈도우 환경 하에서 구현하여 ICCP 프로토콜의 동작과 기능을 보여준다.

  • PDF

해양설치선 ESS Room의 BMS정보를 활용한 Battery 고장예측 (Battery Failure Prediction using BMS Information of ESS Rooms at Offshore Installation Vessel)

  • 김우영;천봉원;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.59-61
    • /
    • 2021
  • 최근 선박/해양설치선의 운항 과정에서 오염물질과 온실가스 배출을 최소화하기 위한 전기추진개발이 진행되고 있다. 이에 필요한 선박/해양설치선 내 ESS 시스템인 배터리의 사용과 효율적 관리에 대한 중요성이 높아지고 있다. 통상적으로 Battery가 적용된 ESS는 BMS에 의해 Cell Balancing 및 수명이 실시간 모니터링이 되고 있다. 선박/해양설치선에는 여러 개소의 ESS Room을 탑재하고 있으며, 최근 전기추진개발 수요로 동일 사양의 ESS 시스템이 적용된 ESS Room이 구성되고 있다. 본 논문에서는 각 Room의 BMS Data를 비교하여 Battery Pack 및 Cell Balancing의 고장을 추가적으로 예측 진단하는 알고리즘을 제안한다. 제안한 알고리즘은 선박/해양설치선의 환경변화에 따른 각 ESS Room의 BMS Data를 비교하여 정확한 상태정보를 측정하고 신뢰성있게 모니터링하여 대형사고를 미연에 방지할 수 있다.

  • PDF

아크 소호용 세라믹 분말을 이용한 높은 차단용량 및 고내구성을 갖는 초소형 퓨즈 설계 (Design of a Miniature Fuse with High Breaking Capacity and Load Life Using a Ceramic Powder of Extinguishing an Electric Arc)

  • 강창룡;진상준;이예지;윤재서;노성여
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.327-332
    • /
    • 2019
  • Recently, inverter control systems have attracted immense attention to increase the energy efficiency. However, such systems use repeated on/off high currents for linear operation control, instead of the prevalent step variable current control method. Hence, there arise concerns of personal and property damage, especially due to the durability, explosive characteristics, and operating speed of the fuse, which is responsible for safety and is one of the internal components using current control. Therefore, in this paper, we propose an IEC60127-4 SMD sub-miniature fuse, consisting of Ag-Cu alloys and ceramic powder for arc soothing. The IEC60127-4 SMD sub-miniature fuse has high durability and cut-off capacity, and operates safely in dangerous circumstances caused by the inverter control system.

남해안 어촌마을 주거시설의 전력소비량 실측조사 (Measurement of Electric Power Consumption of Residences in Southeastern Fishing Village of Korea)

  • 황광일
    • 한국항해항만학회지
    • /
    • 제36권6호
    • /
    • pp.501-506
    • /
    • 2012
  • 해양에너지를 비롯한 신재생에너지를 이용한 분산형 발전시스템 설계의 기초자료로 활용하기 위해 본 연구에서는 도서 주민의 전력소비량을 실측 분석하고 시기별 전력소비 패턴을 개발하였다. 실측조사는 남해안에 위치한 곤리도의 5가구를 대상으로 2010년 10월부터 2012년 2월까지 수행되었다. 월평균 전력소비량은 가구에 따라 12월 혹은 1월에 최대값이 발생하였다. 가구별 월간 전력소비량은 H가구가 J가구보다 2~3배 많았지만 가구별 1인당 월평균 전력소비량은 J가구가 H가구보다 10~30% 가량 많은 것으로 조사되었다. 시각별 전력소비 패턴을 개발한 결과 여름철에는 20시에서 자정 사이에 최대 전력소비가 발생하고, 겨울철은 여름철에 비하여 하루 동안의 전력소비 변화는 완만하지만 18시 이후 자정까지의 시간대에 전력소비가 증가하는 경향을 보였다. 가구별 주중과 주말의 전력소비 패턴은 매우 유사한 것으로 나타났다.

DEA기반 순위결정 절차를 이용한 파레토 최적해의 우선순위 결정: 저수지군 연계 운영문제를 중심으로 (Ranking the Pareto-optimal Solutions using DEA-based Ranking Procedure: an Application to Multi-reservoir Operation Problem)

  • 전승목;김재희;김승권
    • 산업공학
    • /
    • 제21권1호
    • /
    • pp.75-84
    • /
    • 2008
  • It is a difficult task for decision makers(DMs) to choose an appropriate release plan which balances the conflicts between water storage and hydro-electric energy generation in a multi-reservoir operation problem. In this study, we proposed a DEA-based ranking procedure by which the DM can rank the potential alternatives and select the best solution among the Pareto-optimal solutions. The proposed procedure can resolve the problem of mix inefficiency that may cause errors in measuring the efficiency of alternatives. We applied the proposed procedure to the multi-reservoir operation problem for the Geum-River basin and could choose the best efficient solution from the Pareto-set which were generated by the Coordinated Multi-Reservoir Operating Model.