• Title/Summary/Keyword: Elbow pipe

Search Result 96, Processing Time 0.028 seconds

Elastic-Plastic Fracture Mechanics Analyses For circumferential Part-through Surface Cracks At The Interface Between Elbows and Pipes (직관과 곡관의 경계 용접부에 존재하는 원주방향 표면균열에 대한 탄소성 파괴역학 해석)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Yun-Jae;Kim, Jong-Sung;Jin, Tae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1766-1771
    • /
    • 2007
  • This paper presents plastic limit loads and approximate J-integral estimates for circumferential part-through surface crack at the interface between elbows and pipes. Based on finite element limit analyses using elastic-perfectly plastic materials, plastic limit moments under in-plane bending are obtained and it is found that they are similar those for circumferential part-through surface cracks in the center of elbow. Based on present FE results, closed-form limit load solutions are proposed. Welds are not explicitly considered and all materials are assumed to be homogeneous. And the method to estimate the elastic-plastic J-integral for circumferential part-through surface cracks at the interface between elbows and straight pipes is proposed based on the reference stress approach, which was compared with corresponding solutions for straight pipes.

  • PDF

Flow Characteristics in a Pipe with Elbow, Tee or Valve (엘보우, T자관, 밸브가 달린 배관에서의 유동특성)

  • Yoo, S. Y;Lee, S. Y.;Park, K. A.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.253-258
    • /
    • 2000
  • 유량을 정밀하게 측정하기 위해서는 유량계의 위치 선정이 매우 중요하다. 일반적으로 유량계가 설치되는 배관에는 확대관, 축소관, 엘보우, T자관, 밸브 등이 설치된다. 이러한 배관 연결기구는 매우 복잡한 유동현상을 야기하기 때문에 유량 측정에 지대한 영향을 미친다. 따라서 이러한 배관 연결기구가 설치되었을 때 관 내부의 유동현상을 이해하는 것이 유량을 정밀하게 측정할 수 있는 중요한 요소이다. 본 연구에서는 배관에 엘보우 T자관 밸브 등이 설치된 경우에 관내의 유동 특성을 상용코드인 FLUENT를 사용하여 전산해석 하였다. 축방향 속도 2차유동, 압력장 등을 계산하여 고찰하였으며, 또한 완전히 발달된 형태의 유동이 얻어질 때까지의 유동장의 변화를 검토하였다.

  • PDF

Reduction of airborne and structure-borne noise of naval ship pump (함정용 펌프의 공기음 및 고체음저감)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.942-947
    • /
    • 2002
  • In this study, reduction of airborne and structure-borne noise of naval ship pump is presented. Since piping system arrangement such as valve location, flexible joint, pipe diameter and elbow location, discharge basin affect greatly on the noise measurement, care must be taken to minimize the unnecessary noise from the piping system. It is shown that structure-borne noise of the motor with single resilient mount system exceeds criterion. Therefore, it is concluded that double resilient mount system is inevitable. Two kinds of mount is studied for upper mount; spring and rubber type. Although both mounts show good performance at low frequency including rpm frequency, 63Hz, spring mount is found to be inadequate at high frequency, because spring coil acts as a path for SBN.

  • PDF

Installation effects on the characteristics of multi-path ultrasonic flowmeter (배관 형상이 다회선 초음파 유량계의 특성에 미치는 영향)

  • Park, K. A.;Choi, Y. M.;Choi, H. M.;Yoon, B. R.;Hwang, K. B.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.114-117
    • /
    • 1999
  • Five-path ultrasonic flowmeters (200 and 300 mm diameters) were tested to obtain it's characteristics in a water flow standard system. A five-path ultrasonic flowmeter was installed after various pipe fittings (elbow, valve, tee) or a pump. The distance between flow disturbance source and a flowmeter was main experimental parameter. Without a flow conditioner, a five-path ultrasonic flowmeter shows good characteristics as the distance between flow disturbance source and a flowmeter is longer than 10 diameter of a flowmeter.

  • PDF

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

Flow Analysis of POSRV Subsystem of Standard Korean Nuclear Reactor (한국 표준형 원전의 POSRV 하부 배관 유동해석)

  • Kwon, Soon-Bum;Kim, In-Goo;Ahn, Hyung-Joon;Lee, Dong-Eum;Baek, Seung-Cheol;Lee, Byeong-Eun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1464-1471
    • /
    • 2003
  • In order to investigate the flows with shock wave in branch, 108$^{\circ}$ elbow and T-junction of the IRWST system of standard Korean nuclear reactor, detail time dependent behaviors of unsteady flow with shock wave, vortex and so on are obtained by numerical method using compressible three-dimensional Navier-Stokes equations. At first, the complex flow including the incident and reflected shock waves, vortex and expansion waves which are generated at the corner of T-junction is calculated by the commercial code of FLUENT6 and is compared with the experimental result to obtain the validation of numerical method. Then the flow fields in above mentioned units are analyzed by numerical method of [mite volume method. In numerical analysis, the distributions of flow properties with the moving of shock wave and the forces acting on the wall of each unit which can be used to calculate the size of supporting structure in future are calculated specially. It is found that the initial shock wave of normal type is re-established its type from an oblique one having the same strength of the initial shock wave at the 4 times hydraulic diameters of downstream from the branch point of each unit. Finally, it is turned out that the maximum force acting on the pipe wall becomes in order of the T-junction, 108$^{\circ}$ elbow and branch in magnitude, respectively.

The Effect of Pump Intake Leaning Angle and Flow Rate on the Internal Flow of Pump Sump

  • Lee, Youngbum;Kim, Kyung-Yup;Chen, Zhenmu;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.74-80
    • /
    • 2017
  • Pump sump system or pumping stations are built to draw water from a source such as river and used for irrigation, thermal power plants etc. If pump sump is improperly shaped or sized, air entraining vortices or submerged vortices may develop. This may greatly affect pump operation if vortices grow to an appreciable extent. Moreover, the noise and vibration of the pump can be increased by the remaining of vortices in the pump flow passage. Therefore, the vortices in the pump flow passage have to be reduced for a good performance of pump sump station. In this study, the effect of pump intake leaning angle and flow rate on the pump sump internal flow has been investigated. There are three cases with different leaning angle. Moreover, a pipe type with elbow also has been studied. The flow rate with three classes of air entraining vortices has been examined and investigated by decreasing the water level. The result shows that the air entraining vortices easily occurs at the pump intake with large leaning angle. Moreover, the elbow type of the pump intake easily occurs air entraining vortices at the high flow rate (or velocity) in comparison to other pump intake type.

Assessment of Pipe Wall Loss Using Guided Wave Testing (유도초음파기술을 이용한 배관 감육 평가)

  • Joo, Kyung-Mun;Jin, Seuk-Hong;Moon, Yong-Sig
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.295-301
    • /
    • 2010
  • Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion.

Seismic Capacity Test of Nuclear Piping System using Multi-platform Shake Table (다지점 진동대를 이용한 원자력발전소 배관계통의 내진성능실험)

  • Cheung, Jin-Hwan;Gae, Man-Soo;Seo, Young-Deuk;Choi, Hyoung-Suk;Kim, Min-Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.21-31
    • /
    • 2013
  • In this study, dynamic characteristics and seismic capacity of the nuclear power plant piping system are evaluated by model test results using multi-platform shake table. The model is 21.2 m long and consists of straight pipes, elbows, and reducers. The stainless steel pipe diameters are 60.3 mm (2 in.) and 88.9 mm (3 in.) and the system was assembled in accordance with ASME code criteria. The dynamic characteristics such as natural frequency, damping and acceleration responses of the piping system were estimated using the measured acceleration, displacement and strain data. The natural frequencies of the specimen were not changed significantly before and after the testing and the failure and leakage of the piping system was not observed until the final excitation. The damping ratio was estimated in the range of 3.13 ~ 4.98 % and it is found that the allowable stress(345 MPa) according to ASME criteria is 2.5 times larger than the measured maximum stress (138 MPa) of the piping system even under the maximum excitation level of this test.

Elastic-Plastic Fracture Mechanics Analyses for Circumferential Part-Through Surface Cracks at the Interface Between Elbows and Pipes (직관과 곡관의 경계 용접부에 존재하는 원주방향 표면균열에 대한 탄소성 파괴역학 해석)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Jong-Sung;Jin, Tae-Eun;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.6 s.261
    • /
    • pp.710-717
    • /
    • 2007
  • This paper presents plastic limit loads and approximate J-integral estimates for circumferential part-through surface crack at the interface between elbows and pipes. Based on finite element limit analyses using elastic-perfectly plastic materials, plastic limit moments under in-plane bending are obtained and it is found that they are similar those for circumferential part-through surface cracks in the center of elbow. Based on present FE results, closed-form limit load solutions are proposed. Welds are not explicitly considered and all materials are assumed to be homogeneous. And the method to estimate the elastic-plastic J-integral for circumferential part-through surface cracks at the interface between elbows and straight pipes is proposed based on the reference stress approach, which was compared with corresponding solutions fur straight pipes.