Pump sump system or pumping stations are built to draw water from a source such as river and used for irrigation, thermal power plants etc. If pump sump is improperly shaped or sized, air entraining vortices or submerged vortices may develop. This may greatly affect pump operation if vortices grow to an appreciable extent. Moreover, the noise and vibration of the pump can be increased by the remaining of vortices in the pump flow passage. Therefore, the vortices in the pump flow passage have to be reduced for a good performance of pump sump station. In this study, the effect of pump intake leaning angle and flow rate on the pump sump internal flow has been investigated. There are three cases with different leaning angle. Moreover, a pipe type with elbow also has been studied. The flow rate with three classes of air entraining vortices has been examined and investigated by decreasing the water level. The result shows that the air entraining vortices easily occurs at the pump intake with large leaning angle. Moreover, the elbow type of the pump intake easily occurs air entraining vortices at the high flow rate (or velocity) in comparison to other pump intake type.
Keywords
Internal Flow; Pump Intake Leaning Angle; Pump Sump; Water Level;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Japan Association of Agricultural Engineering Enterprise, 1991, Pumping Station Engineering Handbook, Japan.
2 Nagura, T., Shintani, A., Kawaguchi, R., Inagaki, K., Maeda, T., and Hirata, K., 2015, "On Measurements of Complicated Flow Structure in a Suction Sump Using the 3D-PTV and the UVP," Proceeding of the 13th Asian International Conference on Fluid Machinery, Tokyo, Japan.
3 Li, S., Silve, J. M., Lai, Y., Weber, L. J., and Patel, V. C., 2006, "Three-dimensional Simulation of Flows in Practical Water-pump Intakes," Journal of Hydroinformatics, Vol. 8, No. 2, pp. 111-124.
4 Ansar, M. and Nakato, T., 2001, "Experimental Study of 3D Pumpintake Flows with and without Cross Flow," Journal of Hydraulic Engineering, Vol. 127, No. 10, pp. 825-834.   DOI
5 Turbomachinery Society of Japan, 2005, Standard Method for Model Testing the Performance of a Pump Sump, TSJ S002.
6 ANSYS Inc., 2012, ANSYS CFX Documentation,ver. 13, http://www.ansys.com.
7 Matsui, J., Sugino, Y., and Kawakita, K., 2014, "Numerical Simulation on Flow in Pump Sump with Free Surface," In Fluid Machinery and Fluid Engineering, 2014 ISFMFE-6th International Symposium on (pp. 1-5). IET.
8 Menter, F. R., Kuntz, M., and Langtry, R., 2003, "Ten Years of Industrial Experience with the SST Turbulence Model," Turbulence, Heat and Mass Yransfer, Vol. 4, No. 1, pp. 625-632.