• Title/Summary/Keyword: Elbow Effect

Search Result 236, Processing Time 0.035 seconds

The effect of elastic band based of PNF pattern on the U/E function in the spinal cord injury patient (PNF 패턴에 기초한 탄력밴드 훈련이 척수손상 환자의 상지 기능에 미치는 영향)

  • Shin Young-Il;Lee Hyoung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • The purpose of this study was to investigate the effect of elastic band based of PNF pattern on the U/E function in the spinal cord injury patient. 11 subjects with spinal cord injury participated in this study. They took elastic band excercise 5 times per week for 8 weeks. One time excercise spent 35minutes. The therapeutic effect was evaluated by Cybex 6000, BTE Work Simulator, how many seconds they needed to walk 100 meters. 11 cases were examined before, after 8 week, elastic band excercise. The results of this study are as follows; 1. Isokinetic power by Cybex 6000 : The elbow flexion, shoulder flexion and extension were significant difference between test-retest(p<.05). but elbow extension were not significant difference between test-retest. 2. BTE Work Simulator : Wheelchair Propulsion and Steering Torque were significant difference between test-retest(p<.05). 3. Wheelchair Propulsion velocity : There were significant difference between test-retest(p<.05). The findings suggest that SCI patients can improve their Isokinetic power on shoulder and elbow joint, wheelchair propulsion and Steering Torque by BTE Work Simulator, Wheelchair Propulsion velocity through elastic band based of PNF pattern.

  • PDF

The Effect on the Tension Trapezius Muscle of the Height Keyboard Computer (작업대 높이가 승모근의 근긴장도에 미치는 영향)

  • An, Chang-Sik;An, Yun-Hee;Lee, Myeong-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.6
    • /
    • pp.67-75
    • /
    • 2006
  • Purpose: Many kinds of musculoskeletal disease and symptom are caused by the longtime computer works. However, trapezius muscle tonus has not been established in regarding to keyboard height during typing. Therefore, this study is to evaluate the relationship between trapezius muscle tonus and the height of keyboard while typing, controling for the postures of neck, Lumbar, cervical vertebra. Methods: The experimental height of keyboard was set at elbow height, 3cm higher, 6cm higher, 9cm higher, than elbow. We studied trapezius tonus with the mean value for 2 minutes by EMG in 15 males and 15 females worker of hospital in seoul, who did not have a history of muscle disease, neurological signs, nerve damage. Results: In this experimental, as the height of the keyboard went up, the trapezius tonus significantly increased with shoulder abduction of brachium. Second, right and left trapezius tonus appeared similar while typing. Third, the best height that release the trapezius tonus the was as high as elbow and 3cm higher than elbow. Conclusion: With these above results, we suggest that the appropriate height of keyboard during typing to release the trapezius tonus most is the height of the elbow and 3cm higher than elbow. The study has important implications for focusing on the height of VDT worktable and complaining of a pain by oneself which are useful to establish a method of prevention of musculoskeletal disorder in work in the future.

  • PDF

Lateral Epicondylitis of the Elbow by Oriental Medical Treatments : 4 Cases Report (한방치료로 호전된 주관절 외상과염 환자 4례 보고)

  • Uhm, Bong-Kun;Kim, Jeong-Won;Kim, Choo-Young;Han, Sang-Wook;Yang, Kee-Young;Cho, Tae-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.7 no.1
    • /
    • pp.103-112
    • /
    • 2012
  • Objectives : This study was performed to report the effect of oriental medical treatments on the 4 patients with lateral epicondylitis of the elbow. Methods : The 4 patients were treated by Bee Venom acupuncture, Dong-Qi acupuncture, acupuncture on tender points of the origin of the extensor carpi radialis and taping on the extensor carpi radialis. The state of patients was measured by visual analog scale(VAS), elbow range of motion(ROM) and patient's subjective symptom grade(PSSG). Results : After mean 9.5 times of treatments, the recovery of elbow ROM was measured and significant pain relief was seen as the average of VAS changed from 10 to 1.25 and average of PSSG changed from 2.75 to 0.5 grade. Conclusions : These results suggest that oriental medical treatments including Bee Venom acupuncture, Dong-Qi acupuncture, acupuncture, taping are effective to improve the lateral epicondylitis of the elbow.

  • PDF

A Long-term Results of Ulnohumeral Arthroplasy in Primary Osteoarthritis of the Elbow (척상완 성형술을 이용한 주관절 일차성 골관절염 치료의 장기 추시 결과)

  • Shin Sung-Ryong;Kim Hyung-Nyun;Park Yong-Wook;Lee Sang-Soo;Jeong Un-Seob;Kim Do-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.122-126
    • /
    • 2005
  • Purpose: To assess the long-term effect of ulnohumeral arthroplasty and the relationship between radiological recurrence and clinical outcome. Materials and Methods: Eleven elbows with primary osteoarthritis were analyzed at an average of eighty months after ulnohumeral arthroplasty. All patients were male with a mean age of fifty years. The outcomes were assessed using the Mayo Elbow Performance Score(MEPS) and the clinical and radiological results were compared. Results: Four elbows were not painful and six were mildly painful but one was not changed. The mean gain in extension was $15^{\circ}$, in flexion $10^{\circ}$. There were satisfactory results in 8 elbows(73%) and the mean MEPS was 81 points. All of eleven elbows had some degree of recurrent osteoarthritis and there was no correlation between radiological recurrence and clinical endpoints in nine elbows. But in two elbows, it appeared that recurrence of osteophyte at coronoid process was severe and caused fair outcome. Conclusion: Ulnohumeral arthroplasy is one of the effective treatment options for primary osteoarthritis of the elbow. The radiological recurrence did not correlated with the clinical outcome in most cases.

Investigation of the efficacy and safety of ultrasound-standardized autologous blood injection as treatment for lateral epicondylitis

  • Braaksma, Christel;Otte, Jill;Wessel, Ronald N.;Wolterbeek, Nienke
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2022
  • Background: There are various conservative treatment options for lateral epicondylitis (LE). The aim is to evaluate pain, daily functioning, and complications after ultrasound-standardized autologous blood injections in patients with LE. Methods: For this prospective cohort study, consecutive patients (>18 years) diagnosed with LE were included. Autologous blood was injected using a medical device containing an injection disposable with 12 small needles (Instant Tennis Elbow Cure [ITEC]) device. Patient-Rated Tennis Elbow Evaluation (PRTEE), subjective elbow score (SES), palpation and provocation pain, satisfaction, and complications of treatment were measured at baseline and two months after treatment. Paired t-tests and Fisher's exact tests were used for calculating the difference between pre- and post-treatment outcomes. Results: Fifty-five elbows were analyzed. Mean time between pre- and post-treatment was 11.1 weeks (standard deviation [SD], 8.9 weeks). The mean PRTEE score decreased from 68.2 (SD, 15.7) before surgery to 53.2 (SD, 25.9; p<0.001) after. The mean SES improved from 36.9 (SD, 20.8) to 51.7 (SD, 27.4; p<0.001). Despite this improvement, only 44.7% of patients showed relevant clinical improvement in PRTEE, and 37.3% showed significant clinical improvement based on SES. Four patients reported a complication and the injection disposable failed three times. Conclusions: Ultrasound-standardized autologous blood injection using the ITEC device is not an effective tool in reducing symptoms related to LE. This study showed that only half of all patients experienced a positive effect. In this heterogeneous cohort of patients, we showed no added value of ultrasound standardization.

The Effect of Upstream Disturbances on the Performance of Swing Check Valves (상류측 교란요소가 스윙형 역지밸브의 성능에 미치는 영향)

  • Song, Seok-Yoon;Yoo, Seong-Yeon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.1 s.40
    • /
    • pp.41-48
    • /
    • 2007
  • The effect of the upstream flow conditions on the disc stability of the swing check valves was investigated at various upstream flow disturbance sources and distances from the tested check valves. The experimental loop was designed and installed to measure the disc positions, disc back stop load, and differential pressure at flow velocities lot 3 inch and 6 inch swing check valves. The selected disturbance sources are elbow and globe valve. The effect of the disc fluctuation is different depending on the type of disturbance and the distance between the disturbance and the check valve. Disturbances generated by elbow and globe valve located upstream from check valve create greater and more violent disc motion than uniform flow.

The Effect on Grip strength in Change of Wrist Position of Normal Adults (정상 성인의 손목관절 위치가 파악력에 미치는 영향)

  • Cho, Yong-Ho;Hwang, Yoon-Tae;Lee, Mi-Young;Kim, Jong-Ryul
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.33-39
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate the effect of wrist position on grip strength. A Grip-Strength is measurement of muscle strength in hand. It is evaluated for the motor function and handicap of hand, projection of treatment plan. It is important because correct treatment. Methods: Total 80 college students were participated in this study, who consisted of 40 males and 40 females(age range: $20{\sim}26$). A Grip-Strength Dynamometer was used to measure the grip strength in three wrist position(flexion, extension, neutral position) and two elbow position(supination, pronation). The ANOVA was conducted to determine any significant difference in grip strength between the wrist position and the two elbow position. Results: The results were as follows: 1. The grip strength was affected by wrist position changes. 2. The difference of grip strength according to elbow position Was not significant difference (p>0.01). 3. The grip strength i1l neutral position was strongest among 3 position of wrist (p<0.01). Conclusion: A Grip-Strength was significant difference in wrist position. Pronation position was minimum grip-strength but not significant difference between supination and pronation.

  • PDF

Plastic Limit Loads of 90° Elbows with Local Wall-Thinning Using Small Strain FE Limit Analyses (II)- Bending Moment - (소변형 이론에 입각한 감육이 존재하는 90 도 곡관의 소성 한계 하중 (II)- 굽힘 -)

  • Kim, Jong-Hyun;An, Joong-Hyok;Hong, Seok-Pyo;Park, Chi-Yong;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.4
    • /
    • pp.496-505
    • /
    • 2007
  • This paper proposes closed-form plastic limit load solutions for elbows under in-plane bending, via three-dimensional (3-D), small strain FE limit analyses using elastic-perfectly plastic materials. A wide range of elbow and thinning geometries are considered. For systematic analyses of the effect of the axial thinning length on limit loads, two limiting cases are considered; a sufficiently long wall thinning, and the circumferential part-through surface crack. Closed-form plastic limit load solutions for wall thinning with intermediate longitudinal extents are then obtained from these two limiting cases. The effect of the axial extent of wall thinning on plastic limit loads for elbows is highlighted by comparing that for straight pipes. Although the proposed solutions are developed for the case when wall thinning exists in the center of elbows, it is also shown that they can be applied to the case when wall thinning exists anywhere within the elbow.