References
- S. Y. Song, S. Y. Yoo, 2005, 'Analyes of Failure Causes and an Experimental Study on the Opening Characteristics of Swing Check Valves', Journal of Fluid Machinery, Vol. 8, No. 6, pp. 15-25 https://doi.org/10.5293/KFMA.2005.8.6.015
- EPRI, 1993, Application Guidelines for Check Valves in Nuclear Power Plants, EPRI NP- 5479, Rev. 1, pp. 3-14-3-52
- W. J. Rahmeyer, 1983, 'The Effect of Upstream Piping on Swing-Check Valves,' Management and Operation, Journal AWWA, pp. 553-555
- Y. S. Kim, D. W. Kim, S. K. Park, S. Y. Hong, 2003, 'The Effect of Upstream Disturbances on Swing Check Valve Performance,' Proceedings of Korean Nuclear Autumn Meeting. pp. 1-11
- INPO SOER 86-03, 1986, 'Check Valve Failures or Degradation'
- NUREG/CR-4302, 1985, 'Aging and Service Wear of Check Valves Used in Engineered Safety-Feature Systems of Nuclear Power Plants,' Vol. 1
- NUREG/CR-5944, 1993, 'A Characterization of Check Valve Degradation and Failure Experience in the Nuclear Power Industry'
- NUREG/CR-5944, 1995, 'A Characterization of Check Valve Degradation and Failure Experience in the Nuclear Power Industry,' Vol. 2, 1991 Failures
- S. K. Park, I. H. Kim, Y. S. Kim, D. W. Kim, D. H. Lee, S. C. Kang, 2005, 'Development of Diagnostic Method for Check Valve Performance and Failure Cause Analysis annual report'
Cited by
- Development Trends and Present Situation about the Error Detection of Plane Thread of Three-Jaw Chuck vol.241-244, pp.1662-7482, 2012, https://doi.org/10.4028/www.scientific.net/AMM.241-244.36