• 제목/요약/키워드: Elastic band

검색결과 214건 처리시간 0.03초

A New Model for Basic Microsurgical Nerve Repair Simulation: Making the Most Out of Less

  • Bogdan Ioncioaia
    • Archives of Plastic Surgery
    • /
    • 제50권2호
    • /
    • pp.220-221
    • /
    • 2023
  • Microsurgical peripheral nerve repair is a technical and challenging procedure that requires thorough training prior to a real-life operating theater scenario. While the gold standard in training remains training on biological living peripheral nerve specimen, various inanimate models of nerve repair simulation have been described in the past years. The textile elastic band (TEB) obtained from a surgical mask was either covered with a fine silicone sheath or was left bare and was used afterward for end-to-end coaptation. The average diameter of the TEB was 2 mm, similar with the nerves in the distal hand and can be easily crafted out of accessiblematerials such as a surgicalmask and silicone sealant. The silicone that covers the TEB offers more fidelity to the simulation for microsurgical nerve coaptation. The TEB model offers an affordable, available, and easy-to-craft alternative to the existing models for peripheral nerve repair simulation and serves as a good initiation tool before moving on to biological specimens.

불규칙 작용힘들간의 Correlation이 평판의 진동레벨에 미치는 영향 (Effects of Source Correlation on Plates Driven by Multi-point Random Forces)

  • Oh, S.G.;Park, J.D.;Kwak, C.S.
    • 한국정밀공학회지
    • /
    • 제11권1호
    • /
    • pp.166-176
    • /
    • 1994
  • The problem of reducing the vibration level of elastic plates driven by multiple random point forces is analyzed in this study. First, the analytical solution for the vibration level of finite thin plates with four simply supported edges under the action of multiple random point force is derived. By assuming the plates to be lightly damped, an approximate solution for the vibration level of the plate is obtained. A numerical study is carried out to determine an optimal spacing distance between the multiple point forces in order to produce a relative minimum in the plate's vibration level. The optimal spacing distance is shown to depend on the given excitation band. The effects of wave cancellation in the near field of the multiple point forces are discussed by using the equivalence of certain stationary random responses and deterministic pulse responese.

  • PDF

복합운동이 제2형 당뇨병 비만 여성노인의 Irisin, 신체조성 및 당 대사에 미치는 영향 (Effects of Combined Exercise on Irisin, Body Composition and Glucose Metabolism in Obese Elderly Women with Type 2 Diabetes Mellitus)

  • 하수민;김정숙;하민성;김보성;김도연
    • 한국응용과학기술학회지
    • /
    • 제36권4호
    • /
    • pp.1268-1280
    • /
    • 2019
  • 본 연구는 만 65세 이상 85세 이하의 제2형 당뇨병 비만 여성 노인을 대상으로 12주간 복합운동 후 irisin, 신체조성 및 당 대사에 미치는 영향을 구명하기 위하여 복합운동군(n=20), 대조군(n=16)으로 구분하여 실시하였다. 복합운동 프로그램은 야외 걷기 운동과 탄성 밴드 운동을 12주간 주 3회, 1회 60분간 실시하였으며, 야외 걷기 운동의 운동강도는 중강도(RPE 5~6)로 수행되었으며, 탄성 밴드 운동은 1~4주는 저강도(OMNI-RES 3~4), 5~8주는 중강도(OMNI-RES 5~6), 9~12주는 고강도(OMNI-RES 7~8)로 점진적으로 운동강도를 증가시켰다. 그 결과 복합운동군의 irisin이 유의하게 증가하였고(p<.001), 체지방률은 유의하게 감소하였으며(p<.001), 골격근량은 유의하게 증가하였다(p<.001). 당 대사 관련 인자 중 HbA1c(p=.020), 혈당(p<.001)은 유의하게 감소하였고, HOMA-β는 유의하게 증가하였다(p<.001). Irisin의 변화는 체지방률의 변화와 부적 상관이 있는 것으로 나타났고(r=-.423, p=.010), 유산소성 지구력 변화와 정적 상관이 있었다(r=.355, p=.034). 또한, HbA1c(r=-.351, p=.036)와 혈당(r=-.424, p=.010)의 변화는 부적 상관이 있었으며, HOMA-β는 정적 상관이 있는 것으로 나타났다(r=.411, p=.013). 결론적으로 규칙적인 복합운동의 실천은 제2형 당뇨병 비만 여성노인의 혈중 irisin의 수준을 증가하고, 신체조성 변화에 긍정적인 영향을 주는 것으로 나타났다. 그리고 당화혈색소, 공복혈당 및 인슐린 분비능을 개선하여 당 대사 조절 능력에 도움을 주어 당뇨 예방 및 관리를 위해 효과적인 운동으로 권장될 것으로 사료된다.

지반의 비균질성이 탄성파 전파 특성에 미치는 영향에 대한 추계론적 수치해석 연구 (Stochastic numerical study on the propagation characteristics of P-Wave in heterogeneous ground)

  • 송기일
    • 한국터널지하공간학회 논문집
    • /
    • 제15권1호
    • /
    • pp.13-24
    • /
    • 2013
  • 현재 다양한 탄성파 기반의 물리탐사 기법들이 지반조사를 위해 널리 이용되고 있는데 이는 지반의 동적 특성들이 공학적 물성과 상관관계를 갖기 때문이다. 하지만, 지반공학적 물성치들의 고유한 비균질성이 탄성파 속도 및 진폭 등의 전파 특성에 영향을 미침에도 불구하고 그에 대한 고려가 안되고 있는 실정이다. 그래서, 본 연구에서는 지반의 고유한 비균질성이 탄성파 전파특성에 미치는 영향을 규명하기 위하여 추계론적 수치해석 방법을 적용하였다. 탄성파의 도달 시간 변화와 파두 특성에 주안점을 두어 분석을 수행하였다. 지반의 공간적 상관 거리와 파장과의 상관성 및 탄성파 전파거리와 파장과의 상관성이 탄성파의 도달 시간 변화에 미치는 영향에 대하여 조사하였다. Turning band method를 적용하여 변동계수의 범위가 10 ~ 40%인 다양한 비균질 강도를 갖는 지반을 유한차분 그리드에 생성하였다. 유한차분법을 이용하여 비균질 지반에서 탄성파의 전파를 시뮬레이션하였고, 추계론적 기법으로는 Monte Carlo 시뮬레이션 기법을 적용하였다. 추계론적 수치해석 결과, 지반의 비균질 강도가 증가함에 따라 탄성파의 파두 형상의 일그러짐이 현저하게 발생하였고, 그에 따라 탄성파의 도달 시간도 지연되는 것으로 나타났다. 지반의 공간적 상관 거리와 파장과의 상관성 및 탄성파 전파 거리와 파장과의 상관성은 탄성파의 도달 시간 변화와 긴밀한 상관성이 있는 것으로 나타났다.

탄성 압박 밴드를 이용한 인체 부위별 의복압 가압 수준에 관한 연구 (Determination of the Garment Pressure Level Using the Elastic Bands by Human Body Parts)

  • 백윤정;최정화
    • 한국의류학회지
    • /
    • 제32권10호
    • /
    • pp.1651-1658
    • /
    • 2008
  • This study was to decided the proper garment pressure level on the human body parts. Six volunteers (female: 30-40years) put on the same types of bands, a brief, and a non-woven gown. Garment pressure was measured in regular order with the elastic band on the human body parts such as the upper arm, the waist, the thigh, and the calf. At the same time, physiological responses such as the skin blood flow rate on 2 fingers, 7 different skin temperatures, rectal temperature, heat rates, and subjective responses about the pressure sensation, thermal sensation, and humidity sensation were measured and inquired. The results were as follows; 1. The thicker subcutaneous fat thickness, the higher the mean garment pressure on pressurizing the upper arm(p<.001). Also the thicker subcutaneous fat thickness. the thicker the upper arm circumference. 2. Heart rates increased pressured the upper arm and decreased pressured the waist, the thigh, and the calf. The higher the garment pressure, the higher heart rates on all body parts were pressured. Especially lean subjects showed higher physiological load than others. 3. On pressurizing the upper arm, heart rates, rectal temperature, and mean skin temperature were higher than without pressured state and pressured other body parts.4. The proper garment pressure levels were decided 30gf/$cm^2$ for fat people, 20gf/$cm^2$ for others on the upper arms and 24gf/$cm^2$ on the calf.

도시 NATM 터널의 변형율 연화모델을 이용한 지반거동예측 (The Prediction for Ground Movement of Urban NATM Tunnels using the Strain-softening Model)

  • 김영수;정우섭;이성윤;석태룡
    • 한국터널지하공간학회 논문집
    • /
    • 제8권1호
    • /
    • pp.21-30
    • /
    • 2006
  • 도심지 터널은 미고결성 저토피고 지반에 건설되는 경우가 많기 때문에 지반변위가 터널 설계를 지배하며 설계는 기존의 탄성 및 탄소성 모델을 활용한 수치해석적인 방법에 크게 의존하고 있기 때문에 현장의 계측결과에 부합하는 지반 거동을 묘사하키에는 부족한 점이 많다. 미고결성 저토피고 지반에 대한 터널 굴착시 지반 거동, 붕괴 매카니즘 및 침하량 예측에 관해 연구하였고 변형율 연회를 고려한 비선형 해석을 실시하여 기존의 탄성 및 탄소성 모델과 비교하였다. 도시 NATM 터널의 지반거통을 파악한 결과 미고결성 저토피고 지반의 경우 변형율 연화모델을 적용하는 것이 지표면 침하 기울기가 급해지거나 전단대가 발생하는 등 실제의 지반거동을 현실적으로 모델링 할 수 있었다.

  • PDF

유방절제술 환자를 위한 운동프로그램 개발 (Development of an Exercise Program for Postmastectomy Patient)

  • 이자형;조재경;오진아;김성희;안혜임
    • 여성건강간호학회지
    • /
    • 제10권4호
    • /
    • pp.301-310
    • /
    • 2004
  • Purpose: The purpose of this study was to develop an exercise program for postmastectomy patients. Method: This study was conducted from October, 2003 to June, 2004. The exercise program was developed based on literature review and needs assessment using focus group interviews. The subjects for the focus group interview consisted of 11 patients, 13 recovering patients, and 20 nurses from 3 hospitals. Development of the program was proceeded with analysusm design and development steps. Result: The results of the needs assessment using the focus group interview showed that the exercise program was imperative for postmastectomy patients. Based on the results, a home video tape containing 3 steps, was developed. Each step includes warming-up, stretching, the main exercise, and cool-down. Steps 2 and 3 include exercises with an elastic band, and an elastic ball. The program was modified after conducting a pre-test. A self-checklist including shoulder mobility, hand strength, arm volume and subjective comments on how they feel will be used before and after the exercise program. Conclusion: The exercise program will improve breast cancer patients' quality of life and their physical well-being. Further studies are recommended to test the effectiveness of the exercise program.

  • PDF

Strong ground motion characteristics of the 2011 Van Earthquake of Turkey: Implications of seismological aspects on engineering parameters

  • Beyen, Kemal;Tanircan, Gulum
    • Earthquakes and Structures
    • /
    • 제8권6호
    • /
    • pp.1363-1386
    • /
    • 2015
  • The October 23 2011 Van Earthquake is studied from an earthquake engineering point of view. Strong ground motion processing was performed to investigate features of the earthquake source, forward directivity effects during the rupture process as well as local site effects. Strong motion characteristics were investigated in terms of peak ground motion and spectral acceleration values. Directiviy effects were discussed in detail via elastic response spectra and wide band spectograms to see the high frequency energy distributions. Source parameters and slip distribution results of the earthquake which had been proposed by different researchers were summarized. Influence of the source parameters on structural response were shown by comparing elastic response spectra of Muradiye synthetic records which were performed by broadband strong motion simulations of the earthquake. It has been emphasized that characteristics of the earthquake rupture dynamics and their effects on structural design might be investigated from a multidisciplinary point of view. Seismotectonic calculations (e.g., slip pattern, rupture velocity) may be extended relating different engineering parameters (e.g., interstorey drifts, spectral accelerations) across different disciplines while using code based seismic design approaches. Current state of the art building codes still far from fully reflecting earthquake source related parameters into design rules. Some of those deficiencies and recent efforts to overcome these problems were also mentioned. Next generation ground motion prediction equations (GMPEs) may be incorporated with certain site categories for site effects. Likewise in the 2011 Van Earthquake, Reverse/Oblique earthquakes indicate that GMPEs need to be feasible to a wider range of magnitudes and distances in engineering practice. Due to the reverse faulting with large slip and dip angles, vertical displacements along with directivity and fault normal effects might significantly affect the engineering structures. Main reason of excessive damage in the town of Erciş can be attributed to these factors. Such effects should be considered in advance through the establishment of vertical design spectra and effects might be incorporated in the available GMPEs.

산소유량 변화에 의한 산소 과포화된 HfOx 박막의 고온 열처리에 따른 Nanomechanics 특성 연구

  • 박명준;이시홍;김수인;이창우
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.389-389
    • /
    • 2013
  • HfOx (Hafnium oxide)는 ~25의 고유전상수, 5.25 eV의 비교적 높은 Band-gap을 갖는 물질로 MOSFET (metal-oxide semiconductor field-effect-transistor) 구조의 Oxide 박막을 대체 가능한 물질로 연구가 지속되고 있다. 현재까지 진행된 대다수의 연구는 증착 조건에 따른 박막의 결정학적 및 전기적 특성에 대한 주제로 진행되었고 다양한 연구 결과가 보고된바 있다. 하지만 기존의 연구 기법은 박막의 nanomechanics 특성에 대한 연구가 부족하여 이를 보완하기 위한 연구가 절실하다. 따라서 본 연구에서는 HfOx 박막 내 포함된 산소가 고온 열처리 과정에서 빠져나감으로 인한 박막의 nanomechanics 특성을 확인하고자 하였다. 시료는 rf magnetron sputter를 이용하여Si (silicon) 기판위에 Hafnium target으로 산소유량(5, 10, 15 sccm)을 달리하여 증착하였고, 이후 furnace에서 $400^{\circ}C$에서 $1,000^{\circ}C$까지 질소분위기에서 20분간 열처리를 실시하였다. 실험결과 시료의 전기적 특성을 I-V 곡선을 측정하여 확인하였고, 증착 시 산소 유량이 5 sccm에서 15 sccm으로 증가함에 따라서 누설전류 특성은 급격히 향상되었고, 열처리 온도가 증가함에 따라 감소하는 특성을 나타내었다. 또한 시료의 nanomechanics 특성을 확인하기 위하여 nano-indenter를 이용하여 시료의 표면강도(surface hardness)와 탄성계수(elastic modulus)를 확인하였다. 측정결과 5 sccm 시료의 표면강도와 탄성계수는 상온에서 열처리 온도가 증가함에 따라 각각 7.75 GPa에서 9.19 GPa로, 그리고 133.83 GPa에서 126.64 GPa로 10, 15 sccm의 박막의 비하여 상대적으로 균일한 특성을 나타내었다. 이는 증착 시 박막 내 과포화된 산소가 열처리 과정에서 빠져나감으로 인한 것이며, 또한 과포화된 정도에 따라 더 적은 열처리 에너지에 의하여 박막을 빠져나감으로 인한 것으로 판단된다. 또한 열처리 과정에서 산소가 빠져나가는 상대적인 flux의 영향으로 인하여 박막의 mechanical한 균일도의 변화가 나타났다.

  • PDF

납착 방법에 따른 교정용 와이어의 기계적 특성 비교 (A Comparative Evaluation of Mechanical Properties of Orthodontic Wire Joints according to Soldering Methods)

  • 이혜진;홍민호
    • 대한치과기공학회지
    • /
    • 제36권4호
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the tensile strength and mechanical properties of orthodontic wire joints made by gas soldering and laser welding, with and without filling material, to identify the effectiveness and potential clinical application of laser welded orthodontic wires. Methods: Three joint configurations of orthodontic wire were used: diameter 0.9 to 0.9 mm wire, diameter 0.9 to 0.5 wire and diameter 0.9 mm wire to band. The joints were made using three different methods: gas soldering, laser welding with and without filling material. For each kind of joint configuration or connecting method 7 specimens were carefully produced. The tensile strengths were measured with a universal testing machine (Zwick/Roell, Instron, USA). The hardness measurements were carried out with a hardness tester(Future-Tech Co. Tokyo, Japan). Data were analyzed by AVOVA(p= .05) and Turkey HD test(p= .05). Results: In all cases, gas soldering joints were ruptured on a low level on tensile bonding strength. Significant differences between laser welding and gas soldering(p< .05) were found in each joint configuration. The highest tensile strength means were observed for laser welding, with filling material, of 0.9 to 0.9 mm wire joint. Conclusion: In conclusion, the elastic modulus and tensile strength means of laser soldering with filling material were the highest, and the tensile strength means of laser soldering were higher than those of gas soldering.