• Title/Summary/Keyword: Ejection

Search Result 736, Processing Time 0.02 seconds

Comparison of functional Images obtained by radionuclide angiocardiography and gated blood pool scan (방사성핵종 심혈관조영술의 기능적영상화에 대한 고찰)

  • Bom, Hee-Seung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.186-191
    • /
    • 1991
  • Radionuclide cardiac studies lend themselves exceptionally well to functional imaging. This is especially true for gated blood pool scan (GBP). Making functional images is also possible in radionuclide angiocardiography (RNAC). In this study we tried to validate the functional images obtained from RNAC by comparing it with GBP. Twenty three patients (16 patients with coronary artery diseases, 5 with hypertensive heart diseases, and 2 with nonspecific chest pains) underwent simultaneous RNAC and GBP at the same position (LAO $45^{\circ}$). From both studies, global ejection fraction, regional ejection fraction, phase image, amplitude image, stroke image, paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox images of RNAC are very similar to those of GBP. However, amplitude and stroke images are different. Regional ejection fractions of the left ventricular base, maximum ejection and maximum filling rates obtained from RNAC are significantly different from those of GBP. In conclusion, albeit all of functional images of RNAC is not same as GBP, regional walt motions and global left ventricular function are expected to be successfully analyzed by phase and paradox image and ejection fraction.

  • PDF

Electrohydrodynamic Water Droplet Ejection Characteristics from a Micro-Water-Nozzle (미세 수관 노즐의 전기유체역학적 수적 분사특성)

  • Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1632-1637
    • /
    • 2010
  • A micro-water-nozzle, as one of a cooling means of micro-electronic devices, has been proposed and investigated. The I-V characteristics of the micro-water-nozzle and effect of applied voltage on the meniscus formation and deformation and ejection processes of de-ionized water on the micro-water-nozzle tip have been investigated. The water ejection processes, such as a drop formation, a drop deformation, a dripping, a cone jet, and an atomization, were taken place on the micro-water-nozzle tip by the electrohydrodynamic forces acted by the DC and AC high voltages applied on the meniscus of the micro-water-nozzle tip. The I-V characteristics of the micro-water-nozzle-to-plate electrode system were different from that of the same metal-point electrode system, due to the meniscus formation and water droplet ejection at the nozzle tip. The positive and negative DC and AC high voltages showed the water droplets ejection, the ejection rates of 1.8, 1.5 and 1.2 g/h respectively, which, however, showed that the proposed micro-water-nozzle-to-plate electrode system could be used as one of an effective pumping means.

Right Ventricular Ejection Fraction using ECG-Gated First Pass Cardioangiography (방사성동위원소 심조영술상 심전도게이트 일회통과법을 이용한 우심실 박출계수)

  • Moon, Young-Hee;Lee, Hae-Giu;Lee, Sung-Yong;Park, Suk-Min;Chung, Soo-Kyo;Yim, Jeong-Ik;Bahk, Yong-Whee;Shinn, Kyung-Sub;Kim, Young-Gyun;Kwon, Soon-Seog
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.135-139
    • /
    • 1993
  • Radionuclide cardioangiography has been widely applied and has played major roles in non-invasive assessment of cardiac function. Three techniques, first-pass, gated first and gated equilibrium methods, have commonly been used to evaluate right ventricular ejection fraction which usually abnormal in the patients with cardiopulmonary disease. It has been known that the gated first pass method is the most accurate method among the three techniques in assessment of right ventricular ejection fraction. The radionuclide right ventricular ejection fraction values were determined in 13 normal subjects and in 15 patients with chronic obstructive pulmonary disease by the gated first pass method and compared with those of the first pass method because there ha,j been no published data of right ventricular ejection fraction by the gated first pass method in Korea. The values of right ventricular ejection fraction by the gated first pass method were compared with the detas from the pulmonary function test performed in the patients with chronic obstructive pulmomary disease. The results were as follows: 1) The values of right ventricular ejection fraction by the gated first pass method were $50.1{\pm}6.1%$ in normal subjects and $38.5{\pm}8.5$ in the patients with chronic obstructive pulmonary disease. There was statistically significant difference between the right ventricular ejection fraction of each of the two groups (p < 0.05). 2) The right ventricular ejection fraction by the gated first pass method was not linearly correlated with $FEV_1$, VC, DLCO, and FVC as well as $P_aO_2$ and $P_aCO_2$ of the patients with chronic obstructive pulmonary disease. We concluded that right ventricular ejection fraction by the gated first pass method using radionuclide cardioangiography may be useful in clinical assessment of the right ventricular function.

  • PDF

Precise Distribution Simulation of Scattered Submunitions Based on Flight Test Data

  • Yun, Sangyong;Hwang, Junsik;Suk, Jinyoung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.108-117
    • /
    • 2017
  • This paper presents a distribution simulation model for dual purpose improved conventional munitions based on flight test data. A systematic procedure for designing a dispersion simulation model is proposed. A new accumulated broken line graph was suggested for designing the distribution shape. In the process of verification and simulation for the distribution simulation model, verification was performed by first comparing data with firing test results, and an application simulation was then conducted. The Monte Carlo method was used in the simulations, which reflected the relationship between ejection conditions and real distribution data. Before establishing the simulation algorithm, the dominant ejection parameter of the submunitions was examined. The relationships between ejection conditions and distribution results were investigated. Five key distribution parameters were analyzed with respect to the ejection conditions. They reflect the characteristics of clustered particle dynamics and aerodynamics.

A Study of the Human Body Safety and Effectiveness for Scattering Objects on Missile Ejection Round (유도탄 사출시 비산물로 인한 인체 안전과 영향성에 관한 연구)

  • Chung, Sung-Hak;Yun, Hyo-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.180-183
    • /
    • 2014
  • The purpose of this study is to assess for scattering object for the missile ejection round due to analysis of the human body effectiveness safely. To achieve this goal the measurement method of scattering objects by comparative 2 measurement methods studied, the risk of scattering of the object is evaluated. Result of this study, applied in Europe and Japan, based on the safety criteria for the human body effectiveness when missile ejection round. data showed is not effectiveness to the operator's body safely. Data showed that satisfies the safety criteria for missile ejection round in Europe and Japan through the similarity for the case studies. In case of these safety criteria does not exist regulation in South Korea, this study will be referred as guidelines are considered.

Static Ejection Test for Separation Analysis of 2,000lb-Class Store (2,000lb급 장착물의 분리분석을 위한 지상투하시험)

  • Byungjoon Shin;Young-hee Jo;Min-soo Kim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.344-351
    • /
    • 2023
  • Static ejection tests were conducted using the 2,000lb-Class Store to provide ejector model for the store separation simulation. In this study, static ejection test device for 2,000lb-class store was constructed and reaction force applied to store was measured over time. In addition, the trajectories of the ejected store were obtained using photogrammetry and compared with the simulations using developed ejector model. The results of the static ejection test were analyzed to determine the cartridge-orifice combination to be used for store separation. Flight tests were performed by applying the analysis results and verified that the store was safely separated from the aircraft.

Ground Ejection Tests for the Safe Separation Analysis of a Gliding Bomb (활공탄의 안전분리 해석을 위한 지상투하시험)

  • Lee, Kidu;Lee, Inwon;Park, Youngkun;Baek, Seungwoock;Jung, Nahyeon;Jung, Sangjun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.6
    • /
    • pp.502-508
    • /
    • 2013
  • Various combinations of cartridge and orifice were applied for ground ejection tests of a gliding bomb model equipped with a new guidance kit. Larger diameter of orifice made larger ejection force at each of bomb racks. Normal operations of the wing deploying mechanism and the devices inside of the bomb model were confirmed. Also high speed video data showed that pitch angle of the gliding bomb varied due to the ejection force.

Performance Analysis of an Axial Flow Turbine Stage with Coolant Ejection from Stator Trailing Edge (정익 후연의 냉각유체분사를 포함한 축류터빈단의 성능해석)

  • Kim, Tong Seop;Kim, Jae Hwan;Ro, Sung Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.831-840
    • /
    • 1999
  • In this work, an aerothermodynamic calculation model for cooled axial flow turbine blades with trailing edge ejection is suggested and a mean line performance analysis of a turbine stage with nozzle cooling is carried out. A unique model regarding the interaction between coolant and main gas is proposed, while existing correlations are adopted to predict viscous loss and blade outflow angle. The interactions considered are the heat transfer from main gas to coolant and the temperature and pressure losses by the mixing of two streams due to the trailing edge coolant ejection. For a stator blade without ejection, trailing edge loss calculated by the trailing edge analysis is compared with that calculated by loss correlation. The effect of heat transfer effectiveness of coolant passage on the mixing loss is analyzed. For a model turbine stage with nozzle cooling, parametric analyses are carried out to investigate the effect of main design variables(coolant mass flow ratio, temperature and ejection area) on the stage performance.

Effect of Aromatherapy Massage on the Mood, the Milk ejection Reflex, and the Immunoglobulin A of the Breast Milk of Mothers with a Cesarean Section Delivery (향요법마사지가 제왕절개술 산모의 기분, 유즙사출반사, 유즙 면역글로불린A에 미치는 효과)

  • Lee, Seong-Hui
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.5
    • /
    • pp.1357-1367
    • /
    • 2000
  • The purpose of this quasi-experimental study was to explore the effect of aromatherapy massage on the mood, the milk ejection reflex, and the immunoglobulin A of the breast milk of mothers who gave birth through a Cesarean section delivery. Twenty mothers who had Cesarean section were selected as an experimental group, and twenty-two were in the control group. Lavander and Rosemary oil mixed with Jojova carrier oil was used to massage the back, both axillar and breasts. Aromatherapy massage was done once a day for 20 minutes by the researcher. Each session consisted of 4 minutes for warm-up, 14 minutes for massage and 2 minutes for closure. The levels of IgA within the breast milk was analyzed by an immunoturbidimeter assay (Cobas INTEGRA, Roche, Swiss) before and after aromatherapy massage. Mood and milk ejection reflex were measured by self-reports at the same time. The data were analyzed using SPSS 7.5 and the hypotheses were tested by ANCOVA and the Pearson coefficient correlation. The results were as follows : 1) Score of mood increased significantly after the use of aromatherapy massage. 2) Score of milk ejection reflex increased significantly after the use of aromatherapy massage. 3) Level of IgA of breast milk did not change significantly after the use of aromatherapy massage.4) After the use of aromatherapy massage, there wasn't any correlation among mood, milk ejection reflex, and level of IgA of breast milk. In conclusion, the results suggest that aromatherapy massage is an effective nursing intervention to enhance the mood and the milk ejection reflex and to increase the rate of breastfeeding in the breastfeeding mothers under stresses like a Cesarean section.

  • PDF

Ground Ejection Tests to verify the Safe Separation of an Aircraft Mounted Store (항공기 장착 무장의 투하 안정성 검증을 위한 지상무장분리시험)

  • Lee, Jong-Hong;Choi, Seok-Min;Lee, Min-Hyoung;Lee, Chul;Jung, Jae-Won
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.70-75
    • /
    • 2018
  • The mounted store on an aircraft shall be subjected to an ground separation test to verify that a safe separation has been made before it is actually installed to the aircraft. In this study, ground ejection test was conducted with dummy missile to verify the stability of the drop on the land. Bomb rack unit essential to testing ground ejection test, operate at high pressure and produce a significant ejection force to push the missile away from any large orifice. Bomb rack unit modified their bombe pressure and orifice diameter to photograph the drop movement of dummy missile with high-speed camera and to analyze their drop displacement and speed. It is considered useful to provide the initial data for the ejection force analysis on aircraft with actual flight and to carry out the ground separation tests of aircraft with future developments.