• Title/Summary/Keyword: Efficiency evaluation

Search Result 4,706, Processing Time 0.04 seconds

A Study on the Policy Direction of Space Composition of the Future School in Old High School - Focused on The Judgment of Space Relocation for the Application of the High School Credit System - (노후고등학교의 미래학교 공간구성 정책방향에 관한 연구 - 고교학점제 적용을 위한 공간 재배치 판단을 중심으로 -)

  • Lee, Jae-Lim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.21 no.3
    • /
    • pp.1-13
    • /
    • 2022
  • This study is a case study to identify the spatial composition and structural problems of existing schools for spatial innovation as a future school that can operate a credit system for old high schools and establish a mid-to-long-term arrangement plan as a credit system operating school capable of various teaching and learning in the future. The study results are as follows: First, most of the problems of the old high schools entailed that there was very poor connectivity between buildings as most of them were arranged in a single, standard design-type unit building and distributed in multiple buildings. In addition, the floor plan of each building is suggested to be a structure in which student exchange and rest functions cannot be achieved during the break period due to the spatial composition of the classroom and hallway concepts. Second, in the direction of the high school space configuration for future school space innovation, the arrangement plan should be established by reflecting the collective arrangement in consideration of the shortening of the movement route and the expansion of subject areas due to the movement of students on the premise of the subject classroom system. Moreover, it is desirable to provide a square-type space for rest and exchange in the central area where communication and exchange are possible according to the moving class. Third, as the evaluation criteria for relocating old high schools, a space program is prepared based on the number of classes in the future, and legal analysis of school land use and land use efficiency analysis considering regional characteristics are conducted. Based on such analysis data, mid-to-long-term land use plans and space arrangement plans for the entire school space such as the school facility complex are established.

Importance-Satisfaction Analysis of Users of Gochang Jayeonmadang Project (고창 자연마당 조성사업 이용자의 중요도·만족도 분석)

  • Jin Pyo Hong;Yun Jin Shim;Jung Won Sung;Kyeong Cheol Lee;Hyeong keun Kweon;Hui Jae Yun
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.1
    • /
    • pp.5-13
    • /
    • 2023
  • This study was conducted to identify items that should be considered in order to increase user satisfaction in the Jayeonmadang project by analyzing the importance and satisfaction targeting Gochang Jayeonmadang users. As a result of analysis on the importance and satisfaction of Gochang Jayeonmadang users focusing on 20 items in 6 fields, Overall, it was analyzed that they were not satisfied as they were important. In order to increase user satisfaction of Gochang Jayeonmadang, maintenance such as 'cleanliness and hygiene', 'water quality', 'vegetation growth', and 'facility management' should be carefully reflected from the planning and design stage, and careful attention should be paid even after the project. In addition, emphasis should be placed on enhancing the user convenience, such as 'accessibility', 'space layout and utilization efficiency', and 'convenience of route'. And, when promoting the Jayeonmadang project, the purpose of the project should be actively promoted to local residents to raise the residents' awareness of the importance of biodiversity in the city.

A stratified random sampling design for paddy fields: Optimized stratification and sample allocation for effective spatial modeling and mapping of the impact of climate changes on agricultural system in Korea (농지 공간격자 자료의 층화랜덤샘플링: 농업시스템 기후변화 영향 공간모델링을 위한 국내 농지 최적 층화 및 샘플 수 최적화 연구)

  • Minyoung Lee;Yongeun Kim;Jinsol Hong;Kijong Cho
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.4
    • /
    • pp.526-535
    • /
    • 2021
  • Spatial sampling design plays an important role in GIS-based modeling studies because it increases modeling efficiency while reducing the cost of sampling. In the field of agricultural systems, research demand for high-resolution spatial databased modeling to predict and evaluate climate change impacts is growing rapidly. Accordingly, the need and importance of spatial sampling design are increasing. The purpose of this study was to design spatial sampling of paddy fields (11,386 grids with 1 km spatial resolution) in Korea for use in agricultural spatial modeling. A stratified random sampling design was developed and applied in 2030s, 2050s, and 2080s under two RCP scenarios of 4.5 and 8.5. Twenty-five weather and four soil characteristics were used as stratification variables. Stratification and sample allocation were optimized to ensure minimum sample size under given precision constraints for 16 target variables such as crop yield, greenhouse gas emission, and pest distribution. Precision and accuracy of the sampling were evaluated through sampling simulations based on coefficient of variation (CV) and relative bias, respectively. As a result, the paddy field could be optimized in the range of 5 to 21 strata and 46 to 69 samples. Evaluation results showed that target variables were within precision constraints (CV<0.05 except for crop yield) with low bias values (below 3%). These results can contribute to reducing sampling cost and computation time while having high predictive power. It is expected to be widely used as a representative sample grid in various agriculture spatial modeling studies.

Evaluation of surface dose comparison by treatment equipment (치료 장비 별 표면 선량 비교평가)

  • Choi Eun Ha;Yoon Bo Reum;Park Byoung Suk;An Ye Chan;Park Myoung Hwan;Park Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.31-42
    • /
    • 2022
  • Purpose: This study measures and compares the surface dose values in the virtual target volume using Tomotherapy, Halcyon, and TrueBeam equipment using 6MV-Flattening Filter-Free(FFF) energy. Materials and Methods: CT scan was performed under three conditions of without bolus, 0.5 cm bolus, and 1 cm bolus using an IMRT phantom (IBA, Germany). The Planning Target Volume (PTV) was set at the virtual target depth, and the treatment plan was established at 200 cGy at a time. For surface dosimetry, the Gafchromic EBT3 film was placed in the same section as the treatment planning system and repeated measurements were performed 10 times and then analyzed. Result: As a result of measuring the surface dose for each equipment, without, 0.5 cm, 1 cm bolus is in this order, and the result of Tomotherapy is 115.2±2.0 cGy, 194.4±3.3 cGy, 200.7±2.9 cGy, The result in Halcyon was 104.7±3.0 cGy, 180.1±10.8 cGy, 187.0±10.1 cGy, and the result in TrueBeam was 92.4±3.2 cGy, 148.6±5.7 cGy, 155.8±6.1 cGy, In all three conditions, the same as the treatment planning system, Tomotherapy, Halcyon, TreuBeam was measured highly in that order. Conclusion: Higher surface doses were measured in Tomotherapy and Halcyon compared to TrueBeam equipment. If the characteristics of each equipment are considered according to the treatment site and treatment purpose, it is expected that the treatment efficiency of the patient will increase as well as the treatment satisfaction of the patient.

Space Usage and Satisfaction with Privacy in General Hospital Inpatients (종합병원 입원환자의 공간사용 및 프라이버시 만족도)

  • Choi, In Young;Park, Hey Kyung
    • Korea Science and Art Forum
    • /
    • v.36
    • /
    • pp.391-400
    • /
    • 2018
  • To ensure a user-centered treatment environment, hospital construction needs an approach that is not centered on functional aspects such as efficiency or economic feasibility but on the consideration of needs as reflected in user psychology and behavior. Patients who are physically and psychologically vulnerable experience psychological pressure when they are placed in an unfamiliar environment. Most of existing studies however focus on the evaluation of the physical environment, without paying attention to the psychological or behavioral approach to anxiety and stress that patients may experience in a special environment that a hospital may be to them. This study examines general hospital inpatients to understand the usage of major space available and their satisfaction with privacy. This study provides useful primary information needed for the user-centered design of general hospital for improved patient health and welfare. For the purpose of the study, literature review, site investigation, and survey were conducted. Major functional space and privacy in general hospitals were studied, and the site investigation was performed to identify the plans and their status. Survey was also performed to understand the usage of functional space and satisfaction with such space usage as well as satisfaction with privacy. The findings were as follows: (1) Space usage was rated as average in general. It was found that patients used their rooms and lobby on a daily basis. By age, the usage was highest in the group in their 40s; the usage was relatively lower in the groups in their 30s or younger. (2) Space satisfaction was above average, indicating that patients were fairly satisfied. Satisfaction was highest in the lobby space designed with distinct features. By case, satisfaction was highest in Case B, characterized by its wide horizontal space in the rural settings. (3) Satisfaction with privacy in hospital was average, indicating that the demand for privacy was relatively higher but what patients receive in return was lower than their expectation. It was also found that satisfaction with privacy was a crucial element that affected the overall satisfaction with hospital.

Evaluation of Antenna Pattern Measurement of HF Radar using Drone (드론을 활용한 고주파 레이다의 안테나 패턴 측정(APM) 가능성 검토)

  • Dawoon Jung;Jae Yeob Kim;Kyu-Min Song
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.6
    • /
    • pp.109-120
    • /
    • 2023
  • The High-Frequency Radar (HFR) is an equipment designed to measure real-time surface ocean currents in broad maritime areas.It emits radio waves at a specific frequency (HF) towards the sea surface and analyzes the backscattered waves to measure surface current vectors (Crombie, 1955; Barrick, 1972).The Seasonde HF Radar from Codar, utilized in this study, determines the speed and location of radial currents by analyzing the Bragg peak intensity of transmitted and received waves from an omnidirectional antenna and employing the Multiple Signal Classification (MUSIC) algorithm. The generated currents are initially considered ideal patterns without taking into account the characteristics of the observed electromagnetic wave propagation environment. To correct this, Antenna Pattern Measurement (APM) is performed, measuring the strength of signals at various positions received by the antenna and calculating the corrected measured vector to radial currents.The APM principle involves modifying the position and phase information of the currents based on the measured signal strength at each location. Typically, experiments are conducted by installing an antenna on a ship (Kim et al., 2022). However, using a ship introduces various environmental constraints, such as weather conditions and maritime situations. To reduce dependence on maritime conditions and enhance economic efficiency, this study explores the possibility of using unmanned aerial vehicles (drones) for APM. The research conducted APM experiments using a high-frequency radar installed at Dangsa Lighthouse in Dangsa-ri, Wando County, Jeollanam-do. The study compared and analyzed the results of APM experiments using ships and drones, utilizing the calculated radial currents and surface current fields obtained from each experiment.

Effect of Organizational Support Perception on Intrinsic Job Motivation : Verification of the Causal Effects of Work-Family Conflict and Work-Family Balance (조직지원인식이 내재적 직무동기에 미치는 영향 : 일-가정 갈등 및 일-가정 균형의 인과관계 효과 검증)

  • Yoo, Joon-soo;Kang, Chang-wan
    • Journal of Venture Innovation
    • /
    • v.6 no.1
    • /
    • pp.181-198
    • /
    • 2023
  • This study aims to analyze the influence of organizational support perception of workers in medical institutions on intrinsic job motivation, and to check whether there is significance in the mediating effect of work-family conflict and work-family balance factors in this process. The results of empirical analysis through the questionnaire are as follows. First, it was confirmed that organizational support recognition had a significant positive effect on work-family balance as well as intrinsic job motivation, and work-family balance had a significant positive effect on intrinsic job motivation. Second, it was confirmed that organizational support recognition had a significant negative effect on work-family conflict, but work-family conflict had no significant influence on intrinsic job motivation. Third, in order to reduce job stress for medical institution workers, it is necessary to reduce job intensity, assign appropriate workload for ability. And in order to improve manpower operation and job efficiency, Job training and staffing in the right place are needed. Fourth, in order to improve positive organizational support perception and intrinsic job motivation, It is necessary to induce long-term service by providing support and institutional devices to increase attachment to the current job and recognize organizational problems as their own problems with various incentive systems. The limitations of this study and future research directions are as follows. First, it is believed that an expanded analysis of medical institution workers nationwide by region, gender, medical institution, academic, and income will not only provide more valuable results, but also evaluate the quality of medical services. Second, it is necessary to reflect the impact of the work-life balance support system on each employee depending on the environmental uncertainty or degree of competition in the hospital to which medical institution workers belong. Third, organizational support perception will be recognized differently depending on organizational culture and organizational type, and organizational size and work characteristics, working years, and work types, so it is necessary to reflect this. Fourth, it is necessary to analyze various new personnel management techniques such as hospital's organizational structure, job design, organizational support method, motivational approach, and personnel evaluation method in line with the recent change in the government's medical institution policy and the global business environment. It is also considered important to analyze by reflecting recent and near future medical trends.

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

A Data-based Sales Forecasting Support System for New Businesses (데이터기반의 신규 사업 매출추정방법 연구: 지능형 사업평가 시스템을 중심으로)

  • Jun, Seung-Pyo;Sung, Tae-Eung;Choi, San
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.1
    • /
    • pp.1-22
    • /
    • 2017
  • Analysis of future business or investment opportunities, such as business feasibility analysis and company or technology valuation, necessitate objective estimation on the relevant market and expected sales. While there are various ways to classify the estimation methods of these new sales or market size, they can be broadly divided into top-down and bottom-up approaches by benchmark references. Both methods, however, require a lot of resources and time. Therefore, we propose a data-based intelligent demand forecasting system to support evaluation of new business. This study focuses on analogical forecasting, one of the traditional quantitative forecasting methods, to develop sales forecasting intelligence systems for new businesses. Instead of simply estimating sales for a few years, we hereby propose a method of estimating the sales of new businesses by using the initial sales and the sales growth rate of similar companies. To demonstrate the appropriateness of this method, it is examined whether the sales performance of recently established companies in the same industry category in Korea can be utilized as a reference variable for the analogical forecasting. In this study, we examined whether the phenomenon of "mean reversion" was observed in the sales of start-up companies in order to identify errors in estimating sales of new businesses based on industry sales growth rate and whether the differences in business environment resulting from the different timing of business launch affects growth rate. We also conducted analyses of variance (ANOVA) and latent growth model (LGM) to identify differences in sales growth rates by industry category. Based on the results, we proposed industry-specific range and linear forecasting models. This study analyzed the sales of only 150,000 start-up companies in Korea in the last 10 years, and identified that the average growth rate of start-ups in Korea is higher than the industry average in the first few years, but it shortly shows the phenomenon of mean-reversion. In addition, although the start-up founding juncture affects the sales growth rate, it is not high significantly and the sales growth rate can be different according to the industry classification. Utilizing both this phenomenon and the performance of start-up companies in relevant industries, we have proposed two models of new business sales based on the sales growth rate. The method proposed in this study makes it possible to objectively and quickly estimate the sales of new business by industry, and it is expected to provide reference information to judge whether sales estimated by other methods (top-down/bottom-up approach) pass the bounds from ordinary cases in relevant industry. In particular, the results of this study can be practically used as useful reference information for business feasibility analysis or technical valuation for entering new business. When using the existing top-down method, it can be used to set the range of market size or market share. As well, when using the bottom-up method, the estimation period may be set in accordance of the mean reverting period information for the growth rate. The two models proposed in this study will enable rapid and objective sales estimation of new businesses, and are expected to improve the efficiency of business feasibility analysis and technology valuation process by developing intelligent information system. In academic perspectives, it is a very important discovery that the phenomenon of 'mean reversion' is found among start-up companies out of general small-and-medium enterprises (SMEs) as well as stable companies such as listed companies. In particular, there exists the significance of this study in that over the large-scale data the mean reverting phenomenon of the start-up firms' sales growth rate is different from that of the listed companies, and that there is a difference in each industry. If a linear model, which is useful for estimating the sales of a specific company, is highly likely to be utilized in practical aspects, it can be explained that the range model, which can be used for the estimation method of the sales of the unspecified firms, is highly likely to be used in political aspects. It implies that when analyzing the business activities and performance of a specific industry group or enterprise group there is political usability in that the range model enables to provide references and compare them by data based start-up sales forecasting system.

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF