• Title/Summary/Keyword: Efficiency Factor

Search Result 3,816, Processing Time 0.027 seconds

Improvement of Operating Efficiency on Advanced Wastewater Plant Using Statistical Approach (고도처리 효율 향상을 위한 통계적 접근)

  • Moon, Kyung-Sook;Min, Kyung-Sub;Kim, Seung-Min;Lee, Chan-Hyung
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.405-412
    • /
    • 2008
  • Statistical analysis technique was applied to operating parameters and removal efficiency data sets obtained from advanced wastewater treatment plant during 1 year. Through factor analysis three factors derived varimax rotation were selected each plant. Three components explained 96%, 87% of the total variance of the process, respectively. The components on $A_2O$ Plant were identified in the following order : 1) Shortening the SRT during high-flow period, 2) Keeping biomass high on winter 3) factor was related to DO. On DNR plant, we defined them as follows: factor 1, Prolonged the SRT during high-flow period; factor 2 was related to sludge return; factor 3, Influent BOD during low-DO period. This technique was believed to assist operators in identifying priorities to improve operation efficiency.

Bridgeless Buck PFC Rectifier with Improved Power Factor

  • Malekanehrad, Mahdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.323-331
    • /
    • 2018
  • Buck power factor correction (PFC) converters, compared with conventional boost PFC converters, exhibit high efficiency performance in the entire range of universal line voltage. This feature has gotten more attention for eliminating the zero crossing dead angle of buck PFC rectifiers. Furthermore, bridgeless structures for the reduction of conduction losses have been proposed. The aim of this paper is to introduce a single-phase buck rectifier that simultaneously has unity power factor (PF) and bridgeless structure while operating in the continuous conduction mode (CCM). For this purpose, two auxiliary flyback converters without any active switches are applied to a bridgeless buck rectifier to eliminate the zero crossing dead angle and achieve unity power factor, low total harmonic distortion (THD) and high efficiency. The operation and design considerations of the proposed rectifier are verified on a 150W, 48V prototype using a conventional peak-current-mode control. The measurement results show that the proposed rectifier has nearly unity power factor, THD less than 7% and high efficiency.

Design of High Quality Regulator with High Efficiency Based on Half-Bridge Topology (하프 브릿지 컨버터를 기반으로 한 고효율을 갖는 고역률 정류기의 설계)

  • 이준영;문건우;정영석;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.400-409
    • /
    • 1997
  • Design of single stage AC/DC converter with high power factor and high efficiency based on half-bridge topology for low power application is proposed. To obtain design equations, modelling and detailed analysis are performed. The proposed converter gives and power factor and high efficiency by employing aynchronous rectifiers. To verify the performances of the proposed converter 90W-converter has been designed. This prototype converter meets IEC555-2 requirements with near unity power factor.

  • PDF

Comparison of Performance between Symmetric Trapezoidal Fins and Asymmetric Trapezoidal Fins (대칭 사다리꼴 핀과 비대칭 사다리꼴 핀의 성능 비교)

  • Kang, Hyungsuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.205-213
    • /
    • 2016
  • Heat loss and fin efficiency of symmetric and asymmetric trapezoidal fins with variable slope of fin's top surface are obtained by using a two-dimensional analytic method. Shapes of symmetric and asymmetric fins are changed from rectangular through trapezoidal to triangular by adjusting the fin shape factor. The ratio of symmetric trapezoidal fin length to asymmetric trapezoidal fin length is presented as a function of fin base height and convection characteristic number. The ratio of symmetric trapezoidal fin efficiency to asymmetric trapezoidal fin efficiency is presented as a function of the fin base height and fin shape factor. One of results shows that asymmetric trapezoidal fin length is shorter than symmetric trapezoidal fin length (i.e., asymmetric trapezoidal fin volume is smaller than symmetric trapezoidal fin volume) for the same heat loss when the fin base height and fin shape factor are the same.

A Rectifier for DC Arc Holdings Having High Power Factor and Efficiency (고역율, 고효율 직류아아크용접기용 정류기)

  • Cho, Kyu-Min;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.385-388
    • /
    • 1994
  • This paper presents a new configure rectifier which has improved input power factor and efficiency for DC arc weldings. Two rectifiers are series connected and they are single-phase full-wave phase controlled rectifiers that use a transformer with two center-tapped secondary. The input power factor can be improved by controlling the each phase of rectifiers sequentially, and then the efficiency can be also improved because the reactive component currents will be reduced. It is confirmed that the proposed rectifiers has about 80% of input power factor and efficiency with the experimental results which are carried out at the output ranges of 100A to 300A.

  • PDF

Determination of Damping Modification Factor in RC Structures Due to Energy Absorption Efficiency (에너지 흡수효율에 의한 철근콘크리트 구조물의 감쇠비 수정계수 결정)

  • 김장훈;좌동훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.161-166
    • /
    • 2002
  • The modification factor( k-factor) of equivalent damping ratio utilized in the current state-of-the-practice to account for the imperfection of reinforced concrete structures in hysteresis loop is investigated. From this, it is found that the current modification factor does not include the effect of cyclic loading, one of the important characteristic properties of earthquake loading. This could be taken into account by considering the energy absorption efficiency based on the cummulative plastic deformation. From the study, it is suggested that the current approach for the modification factor for the equivalent damping ratio should be reformed.

  • PDF

A study on economic analysis of new renewable energy power(photovoltaic, wind power, small hydro, biogas) (신재생에너지 발전(태양광, 풍력, 소수력, 바이오가스)의 경제성 분석 연구)

  • Kim, Chong-Min;Kim, Ki-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study evaluates a feasibility and economical efficiency of new renewable energy. According as weather change is serious problem now days, every people make attention to the reduction of greenhouse gas. The revitalization of new renewable energy creates the variety of energy source, stability of energy supply and reduction of greenhouse gas. In this study evaluates a feasibility and economical efficiency from new renewable energy of various photo voltaics, wind power, small hydro and biogas. Feasibility does in standard of technical characteristic, politic support, marketability, establishment present condition and development aim. Economical efficiency does in standard of developmental unit cost, utilization factor, equipment life, politic support cost, interest ratio. The results of this study were as follows photo voltaics, wind, small hydropower, biogas in order feasibility is high. Developmental unit cost, utilization factor, equipment life, politic support cost and analyzed the relationship of interest ratio fluctuation and economical efficiency. From all new renewable energy the utilization factor most is important in economical efficiency but necessary utilization factor is difficult because environmental problem.

An Analysis for Influence Factors for IT Governance: Focusing on ITA/EA Functions (IT거버넌스의 영향요인 분석: ITA/EA 기능 중심)

  • Ahn, Yeon-Shick;Kang, Jae-Hwa;Cho, Hyung-Rae;Kim, Moon-Jung
    • Journal of Information Technology Services
    • /
    • v.6 no.2
    • /
    • pp.63-80
    • /
    • 2007
  • In this paper, the function factors contributing to ITA/EA functions in their organizations, are suggested. Also the reasons to the construction of IT governance system and their effects on the their organizations are discussed and the relationships are verified by empirical model. From the survey, the data of the 227 respondents were collected and regression analysis was performed for validating the research model. ITA/EA functions consist of the IT infrastructure systemization, ITA/EA business process support, IT investment efficiency factors. And the factors of IT resource and performance management, IT process management, IT service management are included to IT governance. The main analysis results described significantly are shows as follows. At first, IT resource and performance management factor is effected by the ITA/EA business process support factor and IT investment efficiency factor. In similarly, IT service management factor is also affected by the factors such as ITA/EA business process support, IT investment efficiency, and IT infrastructure systemization. In additional analysis, IT investment efficiency factor in official sectors, ITA/EA business process support factor in private sectors respectively are described as the significant factors on the IT governance.

A Study on the discriminating of the hospitals based on the efficient insurance conversion factor by AHP and DEA (효율적 건강보험수가에 기반을 둔 병원 그룹화에 관한 연구 -AHP와 DEA를 이용한 분석-)

  • O, Dong-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1304-1316
    • /
    • 2009
  • This study is for the pursuit of the basic application of the efficient conversion factor in the fee contract. This aims to investigate the effects of DEA efficiency index and conversion factors to identify and group the 60 hospitals with intern and residents education. To achieve the aims, AHP was used to select the inuput and output variables for DEA. It was found that the more inefficient in the technical and scale side, the higher the conversion factors were. Conversion factor and DEA efficiency index can be used very effectively to group and discriminant hospitals into a specialized general hospital and a general hospital. Even if the variables used to calculate DEA efficiency are applied to discriminant analysis, The conversion factor and DEA efficiency index have a significant power to make a function modeling. So, if we can make a more conclusive proof based on the large number samples, We can imagine to introduce a efficiency concept in the insurance fee contracts about a conversion factor in Korea Health Insurance System.

High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules

  • Choi, Woo-Young;Choi, Jae-Yeon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.561-567
    • /
    • 2011
  • This paper presents a high-efficiency power conditioning system (PCS) for grid-connected photovoltaic (PV) modules. The proposed PCS consists of a step-up DC-DC converter and a single-phase DC-AC inverter for the grid-connected PV modules. A soft-switching step-up DC-DC converter is proposed to generate a high DC-link voltage from the low PV module voltage with a high-efficiency. A DC-link voltage controller is presented for constant DC-link voltage regulation. A half-bridge inverter is used for the single-phase DC-AC inverter for grid connection. A grid current controller is suggested to supply PV electrical power to the power grid with a unity power factor. Experimental results are obtained from a 180 W grid-connected PV module system using the proposed PCS. The proposed PCS achieves a high power efficiency of 93.0 % with an unity power factor for a 60 Hz / 120 Vrms AC power grid.