• Title/Summary/Keyword: Effective discharge

Search Result 1,005, Processing Time 0.027 seconds

Micro EDM with Ultrasonic Work Fluid Vibration for Deep Hole Machining (깊은 구멍 가공을 위한 가공액 초음파 가진 미세 방전가공)

  • Je Sung Uk;Lee Hae Sung;Chu Chong Nam;Kim Duck Whan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.47-53
    • /
    • 2005
  • Microholes with high aspect ratio are required in microstructures. Among various methods for producing the microhole, micro electrical discharge machining (MEDM) is very effective and useful process. But, it is difficult to machine the high aspect ratio holes below $100\;{\mu}m$ in diameter because machining condition becomes unstable due to bad removal of debris at deep hole. In this paper, ultrasonic vibration is applied to MEDM work fluid to make a high aspect ratio micro hole. It is shown that the vibration is effective in circulating the debris and increasing the machining rate. As a result, produced was a micro hole with $92\;{\mu}m$ entrance diameter, $81\;{\mu}m$ exit diameter and aspect ratio 23.

Analysis and Comparison of Stream Discharge Measurements in Jeju Island Using Various Recent Monitoring Techniques (다양한 첨단 유량 계측기기를 활용한 제주도 하천 유출 비교 분석)

  • Yang, Sung-Kee;Kim, Dong-Su;Jung, Woo-Yul;Yu, Kwon-Kyu
    • Journal of Environmental Science International
    • /
    • v.20 no.6
    • /
    • pp.783-788
    • /
    • 2011
  • Different from the main land of South Korea, Jeju Island has been in difficulties for measuring discharge. Due to high infiltration rate, most of streams in Jeju Island are usually in the dried state except six streams with the steady base flow, and the unique geological characteristics such as steep slope and short traveling distance of runoff have forced rainfall runoff usually to occur during very short period of time like one or two days. While discharge observations in Jeju Island have been conducted only for 16 sites with fixed electromagnetic surface velocimetry, effective analysis and validation of observed discharge data and operation of the monitoring sites still have been limited due to very few professions to maintain such jobs. This research is sponsored by Ministry of Land, Transport and Maritime Affairs to build water cycle monitoring and management system of Jeju Island. Specifically, the research focuses on optimizing discharge measurement techniques adjusted for Jeju Island, expanding the monitoring sites, and validating the existing discharge data. First of all, we attempted to conduct discharge measurements in streams with steady base flow, by utilizing various recent discharge monitoring techniques, such as ADCP, LSPIV, Magnetic Velocimetry, and Electromagnetic Wave Surface Velocimetry. ADCP has been known to be the most accurate in terms of discharge measurement compared with other techniques, thus that the discharge measurement taken by ADCP could be used as a benchmark data for validation of others. However, there are still concerns of using ADCP in flood seasons; thereby LSPIV would be able to be applied for replacing ADCP in such flooded situation in the stream. In addition, sort of practical approaches such as Magnetic Velocimetry, and Electromagnetic Wave Surface Velocimetry would also be validated, which usually measure velocity in the designated parts of stream and assume the measured velocity to be representative for whole cross-section or profile at any specified location. The result of the comparison and analysis will be used for correcting existing discharge measurement by Electromagnetic Wave Surface Velocimetry and finding the most optimized discharge techniques in the future.

A Spatio-Temporal Density Measurement of NO Molecules in Pulsed Barrier Discharge Using Laser Induced Fluorescence (레이져 유기형광법을 이용한 펄스 배리어 방전 공간에서의 NO분자에 대한 시·공간적 밀도변화 측정)

  • Han, Sang-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.160-168
    • /
    • 2010
  • This paper tried to find out NO generation and removal mechanisms in the space of the atmospheric pulsed barrier discharge using laser induced fluorescence method, which is a very effective approach to the measurement of spatio-temporal density of specific molecules. The propagation velocity of the primary streamer reaches about $2.7{\times}10^6$[m/s] and the secondary streamer is produced in the vicinity of positive electrode after the primary streamer finished. In this work, pulse Nd:Yag and Dye lasers are used for generating the specific wavelength of 226[nm], which is possible to excite NO molecules into $A^2{\Sigma}^+{\rightarrow}X^2{\prod}$(0,0) and fluorescence signals as the transition of $A^2{\Sigma}^+{\leftarrow}X^2$(0,2) is measured. For the effective removal of NO molecules in the plasma discharge process, the lower oxygen contents are needed and the influence of secondary streamer for the reduction mechanism of NO molecules is important

Ozone Production Characteristics of the DBD Discharge the Electrode Shape at the Same Electrode surface area (동일한 전극 표면적에서 DBD방전형 내부전극 형상에 따른 오존생성특성 연구)

  • Kwon, Young-Hak;Park, Hyunmi;Song, HyunGig;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.71-77
    • /
    • 2016
  • The dielectric barrier discharge (DBD) has low efficiency due to about 70% input power is consumed as thermal energy in the discharge space. However, because of the usage of DBD ozone generator is easier than other methods. The DBD ozone generator has been widely applied for high concentration ozone generation in the industrial application. But, the low-capacity compact DBD ozone generator is not applied so far. Therefore, the DBD ozone generator is necessary to improve ozone production efficiency and reduce the capacity. In this paper, the stainless steel pipe inner electrode was designed with hall type and screw type to improve the ozone production yield. The manufactured two inner electrodes were experimented with normal type for comparison of the discharge characteristics and the ozone generating characteristics. As the experimental results, the discharge current effective value of designed inner electrodes with hall type and screw type are higher than the normal type, due to unequal electric field is formed at the boundary. However, the difference of designed and original electrodes is less than 0.1mA that has no effect on the discharge characteristic. On the other hand, the screw type inner electrode increased higher than original model about 7 times when the flow rate of the oxygen source gas was increased from $0.6{\ell}/min$ to $1.0{\ell}/min$ The reason was assumed by the flow rate of the raw gas through the inner electrode was became fast that has a cooling effect. The designed hall type and screw type inner electrodes have shown good performances in ozone generation and ozone production that better than normal type in the same electrode surface area.

Short-range Monitoring of Marine AtoN Charge and Discharge Controller (해상용 항로표지 충·방전조절기의 근거리 모니터링)

  • Ye, Seong-Hyeon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.933-939
    • /
    • 2015
  • If the Visual Aids(light wave signs) is not supplied the general power it is using solar power system. These power supply systems, the role of the charge/discharge control is very important. Introduction of IT(AIS etc.) for the effective management of the AtoN(Aids to Navigation) is a Visual Aids has been added to the device using the power to charge/discharge control, the need increases. The current charge/discharge controller is attached to the inside of the AtoN and checks on and verification of the maritime environment, depending on the difficulty. In order to resolve these issues in this paper, the Bluetooth module is mounted on the inside of the charge/discharge controller and proposed a possible system monitoring at close range. Advantage of the system implemented is a simple configuration and low installation cost. In addition, it can be applied to a variety of AtoN. Also, it has been able to check the real-time status information of the charge/discharge controller at a short distance in to reduce inspection costs, and reduce risk factors that might occur during check.

Comparative Study on the Runoff Process of Granite Drainage Basins in Korea and Mongolia

  • Tanaka, Yukiya;Matsukura, Yukinori
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.79-84
    • /
    • 2003
  • This study revealed the differences in runoff processes of granite drainage basins in Korea and Mongolia by hydrological measurements in the field. The experimental drainage basins are chosen in Korea (K-basin) and Mongolia (M-basin). Occurrence of intermittent flow in K-basin possibly implies that very quick discharge dominates. The very high runoff coefficient implies that most of effective rainfall quickly discharge by throughflow or pipeflow. The Hortonian overlandflow is thought to almost not occur because of high infiltration capacity originated by coarse grain sized soils of K- basin. Very little baseflow and high runoff coefficient also suggest that rainfall almost does not infiltrate into bedrocks in K-basin. Flood runoff coefficient in M-basin shows less than 1 %. This means that most of rainfall infiltrates or evaporates in M-basin. Runoff characteristics of constant and gradually increasing discharge imply that most of rainfall infiltrates into joint planes of bedrock and flow out from spring very slowly. The hydrograph peaks are sharp and their recession limbs steep. Very short time flood with less than 1-hour lag time in M-basin means that overland flow occurs only associating with rainfall intensity of more than 10 mm/hr. When peak lag time shows less than 1 hour for the size of drainage area of 1 to 10 km2, Hortonian overland flow causes peak discharge (Jones, 1997). The results of electric conductivity suggest that residence time in soils or weathered mantles of M-basin is longer than that of K-basin. Qucik discharge caused by throughflow and pipeflow occurs dominantly in K-basin, whereas baseflow more dominantly occur than quick discharge in M-basin. Quick discharge caused by Hortonian overlandflow only associating with rainfall intensity of more than 10 mm/hr in M-basin.

  • PDF

An Estimation of Discharge Coefficient Considering the Geometrical Shape of Broad Crested Side Weir (광정횡월류위어의 기하학적 형상을 고려한 유량계수 산정)

  • Cho, Hong-Je;Kang, Ho-Seon
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.12
    • /
    • pp.955-965
    • /
    • 2011
  • The flow characteristics of rectangular and 1 : 1 and 1 : 2 trapezoidal weirs were investigated through hydraulic experiments in order calculate the exact overflow discharge of the broad-crested side weir. The flow was found to be most stable in trapezoidal shapes with the lowest incline. The 1 : 1 and 1 : 2 trapezoidal weirs had 5.67% and 8.57% increases, respectively, compared to the rectangular weir in terms of overflow amount, which suggests that they are more effective in preventing flood. An integrated discharge coefficient equation taking into account the discharge coefficient equation and shapes was proposed through a multiple linear regression analysis with an addition of a new parameter for the side wear, $L/L_H$, to the conventional discharge coefficient equation. Also, the applicability of the newly proposed discharge coefficient equation was reviewed by comparing the measured and calculated overflow amounts based on the experimental data of preceding researches and existing researchers and the research data of this study.

Study on the Calculation Method of Design Flood Discharge of Dam (댐 설계홍수량 산정방법에 관한 연구)

  • Lee, Jai-Hong;Moon, Young-Il;Beck, Yoo-Hyun;Jang, Kwang-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.277-281
    • /
    • 2011
  • In this study, past method and recent method for flood discharge with domestic multi-purpose dams in Korea were compared and analyzed with respect to the scale of watershed. Rainfall depth, temporal distribution, effective rainfall, rainfall-runoff model, parameter estimation and base flow were selected as the principal factors affecting flood discharge and effects on flood discharge were analyzed quantitatively by using sensitivity analysis. The results showed that the flood discharges calculated by past and recent method increased and decreased with a wide range of discharge with respect to the scale of watershed. The reason for decrease of flood discharge is the exchange of temporal distribution pattern of rainfall and the principal reason for increase of flood discharge are the increase of rainfall depth by unusual weather phenomena and the difference of estimation method of parameters of unit hydrograph.

  • PDF

Study on Discharging Agent for Discharge Printing of Fabrics Dyed with Vinylsulfonyl Reactive Dyes ―Discharge Possibility of Some Chemicals― (부가형 반응염료로 염색된 면직물의 발염에 있어 발염제에 관한 연구 -여러가지 약제들에 의한 발염 가능성-)

  • Park, Geon Yong;Ro, Duck Kil
    • Textile Coloration and Finishing
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • In discharge printing of cotton fabrics dyed with C.I. Reactive Orange 16(O-16), C.I. Reactive Blue 19(B-19) and C.I. Reactive Black 5(Bl-5), when the dyes were discharged by some chemicals, such as $K_{2}CO_{3}$, BASB, DSR, sarcosine and GSB, the single use of those chemicals made a very poor discharge, but mixing them with $K_{2}CO_{3}$ resulted to the outstanding improvement of discharge. Especially the dischargeability of $K_{2}CO_{3}$ BASB or $K_{2}CO_{3}$+DSR was very gratifying. For O―16, $K_{2}CO_{3}$+ DSR was slightly more effective than $K_{2}$CO$_{3}$+BASB, but for B―19 and Bl―5 $K_{2}CO_{3}$+BASB and $K_{2}CO_{3}$+DSR showed similar good results. In discharging of O―16 and B―19 by $K_{2}CO_{3}$+BASB or $K_{2}CO_{3}$ +DSR, the dischargeabilities of them increased as the time of 102$^{\circ}C$ steaming increased under the condition of 102$^{\circ}C$ steaming and no baking, but not under the condition of 102$^{\circ}C$ steaming and 16$0^{\circ}C$ baking. However for Bl-5, without regard to baking, the 102$^{\circ}C$ steaming of more than 15 minutes caused the discharge to be much more remarkable than that of 8 minutes did. Generally baking elevated the dischargeability, and this was sure in discharging by $K_{2}CO_{3}$+BASB or $K_{2}CO_{3}$+DSR. And it was confirmed that the structure of vinylsulfonyl reactive dyes could effect on the dischargeability because the three dyes, though little, showed different discharge behaviors.

  • PDF

One-Plate Type Hybrid Plasma Discharge Device with Heating Element (히터 일체형 하이브리드 단판형 플라즈마 방전소자)

  • Choi, Woo Jin;Choi, Eun Hye;Sung, Hyeong Seok;Kwon, Jin Gu;Lee, Seong Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.320-326
    • /
    • 2019
  • Recently, the application of atmospheric plasma technology in air filtration is increasing. Sterilization by an atmospheric plasma device is very effective. However, ozone gas, which is generated during atmospheric plasma formation, poses a hazard to human health. To reduce the ozone gas during plasma discharge, we fabricated a one-plate hybrid plasma discharge device with a heating element, which can decompose ozone gas effectively by a simple heating action. In this study, we evaluated the plasma discharge characteristics and ozone concentrations with various Ar flow rates and temperatures. With increasing Ar gas flow rate, the ozone concentration and spectrum intensity increased till an Ar gas flow rate of 60 sccm, and decreased thereafter. When discharged in high temperature, the ozone concentration and spectrum intensity decreased. Further, to evaluate the state of the treated surface under various plasma discharge and heating conditions, we measured the variation in the contact angles on the surface. Regardless of the temperature, the contact angle increased with increasing discharge voltage. However, the contact angle increased when discharged at high temperature.