• 제목/요약/키워드: Effective Transfer Function

검색결과 214건 처리시간 0.028초

준정근사계산법을 이용한 탄성표면파 변환기의 특성 해석 (The Analysis of SAW IDT Characteristics Using Quasi-Static Approximation)

  • 이동도;정영지;이재경;황금찬
    • 전자공학회논문지A
    • /
    • 제30A권11호
    • /
    • pp.88-98
    • /
    • 1993
  • In this paper, the effective permittivity in the piezoelectric material is numerically obtained and greens function is derived from that. It is shown that the admittance and the transfer function of an interdigital transducer is represented by electrostatic charge distribution using Quasi-static approximation. To prove the validity of the quasi-static approximation, numerical results for the uniform IDT of a filter mounted on 128 $^{\circ}$ rotated Y-cut X-propagating Lithium Niobate are compared with the measured ones.

  • PDF

MEMS 로 제작된 마이크로 채널에서의 3 차원 열전달 해석 (3D simulation of Heat transfer in MEMS-based microchannel)

  • 최치웅;허철;김동억;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1870-1875
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method for high heat flux source. Contrary to conventional circular channel, MEMS based microchannel had rectangular or trapezoidal cross-sectional shape. In our study, we conducted three dimensional conjugate heat transfer calculation for rectangular shape microchannel. First, we simulated that channel was completely drained with known heating power. As a result we obtained calibration line, which indicates heat loss was function of temperature. Second, we simulated single phase heat transfer with various mass flux, 100-400 $kg/m^2s$. In conclusion, the single phase test verified that the present heat loss evaluation method is applicable to micro scale heat transfer devices. Heat fluxes from each side wall shows difference due to non-uniform heating. However those ratios were correlated with supplied total heat. Finally, we proposed effective area correction factor to evaluate appropriate heat flux.

  • PDF

Design and Performance Verification of a LWIR Zoom Camera for Drones

  • Kwang-Woo Park;Jonghwa Choi;Jian Kang
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.354-361
    • /
    • 2023
  • We present the optical design and experimental verification of resolving performance of a 3× long wavelength infrared (LWIR) zoom camera for drones. The effective focal length of the system varies from 24.5 mm at the wide angle position to 75.1 mm at the telephoto position. The design specifications of the system were derived from ground resolved distance (GRD) to recognize 3 m × 6 m target at a distance of 1 km, at the telephoto position. To satisfy the system requirement, the aperture (f-number) of the system is taken as F/1.6 and the final modulation transfer function (MTF) should be higher than 0.1 (10%). The measured MTF in the laboratory was 0.127 (12.7%), exceeds the system requirement. Outdoor targets were used to verify the comprehensive performance of the system. The system resolved 4-bar targets corresponding to the spatial resolution at the distance of 1 km, 1.4 km and 2 km.

과도 안정도를 고려한 가용송전용량(ATC) 계산에 관한 연구 (A Study on The Available Transfer Capability(ATC) with Transient Stability Constraints)

  • 김양일;정성원;김재현
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.437-443
    • /
    • 2009
  • In recent years, electric power systems have been experiencing a rapid change due to the increasing electricity market. For the effective use of power system under the deregulated environment, it is important to make a fast and accurate calculation of the maximum available transfer capability (ATC) from a supply point to a demand point. In this paper, the purpose of this research is to calculate ATC fast and accurately for securing the stability of system and raising the efficiency as a result of anticipating transmission congestion according to transmission open access progressed in the future under the regulated environment of electricity market. In this paper, a study utilized a relation of the potential energy and energy function by which calculated CCT and then utilized a relation of PEBS for transient stability ATC calculation. In this paper, ATC was calculated as RPF and Energy Function method and calculation results of each method was compared. Contingence ranking method decided the weak bus by the Eigenvalues of Jacobian matrix and overloading branches by PI-index. As a result, a study proved the fast and accurate ATC calculation method considering transient stability suggested in this paper. Through the case study using New England 39 bus system, it is confirmed that the proposed method can be used for real time operation and the planning of electric market.

영산강 수계에서 남조류 세포수 모의를 위한 입출력 모형의 개발 (Input output transfer function model development for a prediction of cyanobacteria cell number in Youngsan River)

  • 이은형;김경현;김상현
    • 한국수자원학회논문집
    • /
    • 제49권9호
    • /
    • pp.789-798
    • /
    • 2016
  • 최근의 우리나라 수계에서의 하천에서의 조류 대번성은 심각한 사회 환경적 문제가 되고 있다. 이중 독성이 강한 남조류의 발현은 수생태계의 건강성과 안전한 물공급에 위협이 될 수 있다. 영산강 수계의 승촌보와 죽산보 지점의 남조류 세포수와 환경인자간의 인과관계 분석을 위해 선백색화 시계열간의 배타적 상관분석을 수행하였고 이를 기반으로 이들 사이의 입출력 모형을 도출하였다. 입출력 모형의 겨울철 남조류 세포수 반응 특성을 고려하기 위해서 수온의 문턱거동을 도입하였고, 모형의 남조류 세포수에 대한 설명력을 증가시키는 효과를 얻었다. 입출력 모형의 남조류 세포수의 모의능이 완전하진 않으나, 비교적 간단한 구조를 가진 입출력 모형의 구조는 모형 적용의 용이성이 높은 것으로 판단된다.

진동대실험에 의한 동조액체기둥감쇠기의 동적특성 (Dynamic Characteristics of Tuned Liquid Column Dampers Using Shaking Table Test)

  • 민경원;박은천
    • 한국소음진동공학회논문집
    • /
    • 제19권6호
    • /
    • pp.620-627
    • /
    • 2009
  • Shaking table test was carried out to obtain dynamic characteristics of TLCDs with uniform and non-uniform sections for both horizontal and vertical tubes. The input to the table is harmonic acceleration with constant magnitude. The output is horizontal dynamic force which is measured by load cell installed below the TLCD. Transfer functions are experimentally obtained using the ratio of input and output. Natural frequency, the most important design factor, is compared to that by theoretical equation for TLCDs with five different water levels. System identification process is performed for experimentally obtained transfer functions to find the dynamic characteristics of head loss coefficient and effective mass of TLCDs. It is found that their magnitudes are larger for a TLCD with non-uniform section than with uniform section and natural frequencies are close to theoretical ones.

Vibration Suppression Control for Mechanical Transfer Systems by Jerk Reduction

  • Hoshijima, Kohta;Ikeda, Masao
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권6호
    • /
    • pp.614-620
    • /
    • 2007
  • This paper considers vibration suppression of a mechanical transfer system, where the work is connected with the hand flexibly. We adopt the idea of jerk reduction of the hand. From the equation of motion, we first derive a state equation including the jerk and acceleration of the hand, but excluding the displacement and velocity of the work. Then, we design optimal state feedback for a suitable cost function, and show by simulation that jerk reduction of the hand is effective for vibration suppression of the work and improvement of the settling time. Since state feedback including the jerk and acceleration is not practical, we propose a computation method for optimal feedback using displacements and velocities in the state only.

충전탑에서 흡수에 따른 물질전달과 수력학적 거동에 관한 연구 (A Study on Hydraulic Behavior and Mass Transfer by Absorption in Packing Tower)

  • 김석택
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.393-396
    • /
    • 2000
  • Packing tower has been used in the chemical industry and the protection of environment for a long time. In the view of environmental protection purification of exhaust gas can be performance effective by gas absorption in counter-current packing tower. In this study characteristics of hydraulic and mass transfer were investigated in D. $0.3m {\times} H. 1.4m$ packing tower with 50mn plastic Hiflow-ring. This study was carried out "Test systems were experimented in conditions of Air, $Air/H_2O. NH_3-Air/H_2O, NH_3-Air/H_2O-H_2SO_4$ and $SO_2-Air/H_2O-NaOH$ under steady state" The extent of test included dry and wetting pressure drop physical law separation efficiency and hold-up as function of gas and liquid load.quid load.

  • PDF

착상시 핀-관 열교환기의 열적 성능 예측을 위한 해석 (An Analysis for Predicting the Thermal Performance of Fin-Tube Heat Exchanger under Frosting Condition)

  • 이태희;이관수;김우승
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.299-306
    • /
    • 1996
  • This work presents an analytical model, so called modified LMTD method, to predict the thermal performance of finned-tube heat exchanger under frosting conditions. In this model, the total heat transfer coefficient and effective thermal conductivity of the frost layer were defined as a function of frost surface temperature. The surface temperature of the frost layer formed on the heat exchanger was calculated through the analysis of the heat and mass transfer process in the air and frost layer. To examine the validity of this analytical model, the computed results from the present model, such as heat transfer rate, frost mass and thickness of frost, were compared with the ones of the expermental work and LMED method.

  • PDF

폐쇄형 대기행렬 네트워크에 의한 FMS 모델링 (A Study on Modeling of FMS using Closed Queueing Network)

  • 정석찬;조규갑
    • 대한산업공학회지
    • /
    • 제21권2호
    • /
    • pp.153-165
    • /
    • 1995
  • Many closed queueing network models have been used as an effective tool to make a preliminary design of FMS. Although a loading/unloading function is an important factor to effect the utilization and throughput of FMS as well as a transfer function and a processing function, the Solberg's model did not clarify the loading/unloading function. In this paper, we propose a closed queueing network model for analyzing a flexible manufacturing system that consists of a load/unload station, a material handling system and a group of workstations for processing jobs, and define the expected utilization and the expected throughput of the FMS. As applications of the proposed model, the cases of a material handling system consisting of a conveyor and the FMS including an inspection station are also formulated.

  • PDF