• 제목/요약/키워드: Eddy Current Loss

검색결과 218건 처리시간 0.02초

등가회로를 이용한 전력용 변압기의 과도응답 특성 해석 (Analysis of Impulse Response of Power Transformer using Electric Equivalent Circuit)

  • 장경운;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.97-99
    • /
    • 1998
  • This paper presents a numerical study of the behavior of the transformer winding, when stressed by the standard impulse voltage. The mathematical model of the transformer takes several points into the account. Capacitance of not adjacent winding as well as adjacent winding, eddy current loss caused by self and mutual inductance given as the functions of frequency. Not like the previous approach where calculation of capacitance is performed, in average sense. In this paper, capacitance of both adjacent and not adjacent winding is calculated using the numerical approach(B.E.M.), so they can get the more accurate value of capacitance. Because of frequency dependency of inductance, numerical-laplace-transform technique is required. Finally, to validate this approach, a simple test winding is simulated.

  • PDF

Comparative Analysis of Flux-Reversal Motors with Six-Switch and Four-Switch Converters

  • Kang, Hyun-Soo;Lee, Byoung-Kuk;Kim, Tae Heoung
    • Journal of Magnetics
    • /
    • 제18권1호
    • /
    • pp.50-56
    • /
    • 2013
  • In this paper, the 6-switch inverter for the Flux-Reversal Motor (FRM) has been presented and compared to the 4-switch inverter for the FRM, which is more popular in cost effective applications. To analyze the FRM, we adopted the two-dimensional time-stepped voltage source finite element method (FEM) that uses the actual pulse width modulation (PWM) voltage waveforms as the input data. As the FRM characteristic analysis of actual pwm voltage input, the torque ripples and iron losses (eddy current and hysteresis loss) of the FRM can be precisely calculated. With the simulated and experimental results, the performance and limitations of the 4-switch FRM which is the cost effective drive compared to the 6-switch FRM drive are provided in more detail.

Influence of Frequency on Electromagnetic Field of Super High-Speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Wang, Wei;Tang, Bingxia;Zhao, Xifang;Yang, Cunxiang
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.980-988
    • /
    • 2019
  • When compared with traditional power frequency generators, the frequency of a super high-speed permanent magnet generator (SHSPMG) is a lot higher. In order to study the influence of frequency on the electromagnetic field of SHSPMGs, a 60000rpm, 117kW SHSPMG was taken as a research object. The two-dimensional finite element model of the generator was established, and the two-dimensional transient field of the generator was simulated. In addition, a test platform of the generator was set up and tested. The reliability of the simulation was verified by comparing the experiment data with that of the simulation. Then the generator electromagnetic field under different frequencies was studied, and the influence mechanism of frequency on the generator electromagnetic field was revealed. The generator loss, voltage regulation rate, torque and torque ripple were analyzed under the rated active power load and different frequencies. The influences of frequency on the eddy current density, loss, voltage regulation rate and torque ripple of the generator were obtained. These conclusions can provide some reference for the design and optimization of SHSPMGs.

철계 연자성 분말용 하이브리드 절연 코팅막 개발 (Development of Hybrid Insulating Coating for Fe-based Soft Magnetic Powder)

  • 김정준;김선겸;김영균;장태석;김휘준;김용진;최현주
    • 한국분말재료학회지
    • /
    • 제28권3호
    • /
    • pp.233-238
    • /
    • 2021
  • Iron-based amorphous powder attracts increasing attention because of its excellent soft magnetic properties and low iron loss at high frequencies. The development of an insulating layer on the surface of the amorphous soft magnetic powder is important for minimizing the eddy current loss and enhancing the energy efficiency of high-frequency devices by further increasing the electrical resistivity of the cores. In this study, a hybrid insulating coating layer is investigated to compensate for the limitations of monolithic organic or inorganic coating layers. Fe2O3 nanoparticles are added to the flexible silicon-based epoxy layer to prevent magnetic dilution; in addition TiO2 nanoparticles are added to enhance the mechanical durability of the coating layer. In the hybrid coating layer with optimal composition, the decrease in magnetic permeability and saturation magnetization is suppressed.

비용 효율이 높은 24kV급 고압배전반 개발을 위한 Bus Bar 사이즈에 따른 전·자기 손실 특성 분석 (A Study on the Characteristics of the Electric Field and Electromagnetic Loss according to Bus Bar Size for a cost-effective 24kV High Voltage Switchgear)

  • 홍종기;허정일;남석호;강형구
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.220-224
    • /
    • 2012
  • The analysis on the bus bar effect is conducted to develop a cost effective 24kV/2,000A switchgear. The temperature enclosures and bus bars could rise due to several heat sources such as eddy current losses and copper losses. Therefore, a study on the characteristics of the electric field intensity and electromagnetic loss according to the bus bar size in a bus bar compartment is essential to design a electrically reliable high voltage switchgear. It is investigated that the electromagnetic influence to the temperature rising and the dielectric stability according to various bus bar sizes by using finite element method(FEM). The electric field intensity and electromagnetic loss according to various bus bar sizes are calculated to design a reliable and a high voltage switchgear. As results, it is found that the electromagnetic loss and the dielectric stability of bus bar could be determined by a bus bar size. It means that a cost effective 24kV/2,000A high voltage switchgear could be developed by selecting the proper size of a bus bar. Also, it is recognized that the electromagnetic characteristics according to various bus bar sizes in order to design an electrically stable high voltage switchgear when the enclosure size is determined as a fixed value. Futhermore, studies on the various nominal voltage class and bus bar sizes will be conducted to develop a cost effective high voltage switchgear.

Design Methodology for Transformers Including Integrated and Center-tapped Structures for LLC Resonant Converters

  • Jung, Jee-Hoon;Choi, Jong-Moon;Kwon, Joong-Gi
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.215-223
    • /
    • 2009
  • A design methodology for transformers including integrated and center-tapped structures for LLC resonant converters is proposed. In the LLC resonant converter, the resonant inductor in the primary side can be merged in the transformer as a leakage inductance. And, the absence of the secondary filter inductor creates low voltage stress on the secondary rectifiers and is cost-effective. A center-tapped structure of the transformer secondary side is widely used in commercial applications because of its higher efficiency and lower cost than full-bridge structures in the rectifying stages. However, this transformer structure has problems of resonance imbalance and transformer inefficiency caused by leakage inductance imbalance in the secondary side and the position of the air-gap in the transformer, respectively. In this paper, gain curves and soft-switching conditions are derived by first harmonic approximation (FHA) and operating circuit simulation. In addition, the effects of the transformer including integrated and center-tapped structures are analyzed by new FHA models and simulations to obtain an optimal design. Finally, the effects of the air-gap position are analyzed by an electromagnetic field simulator. The proposed analysis and design are verified by experimental results with a 385W LLC resonant converter.

투자율이 높은 NiFe 코어를 이용한 마이크로 트랜스포머 제작 (Fabrication of the Micromachined Transformer using High Permeability NiFe Core)

  • 조세준;차두열;이재혁;이수진;장성필
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.194-198
    • /
    • 2010
  • Recently as the electronic devices are getting to be more and more smaller, transformers are needed to be micro fabricated using MEMS technology. In this paper transformers have been fabricated and measured by depositing insulation layer to reduce the loss of eddy current and in the middle core a high permeability permalloy was designed based on the turns ratio between primary coil and secondary coil which are 1:1 transformers. (the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7). The size of the transformers including ground shield are $1mm{\times}1.5mm$, $1mm{\times}1.95mm$, $1mm{\times}2.35mm$ respectively. The line width, pitch and the height of post are 50um. Based on the measured data from the micro fabricated transformers, the 3/3 turns in the primary coil and secondary coil showed the lowest insertion loss with 1.5 dB at 480 MHz and the 7/7 turns in the primary coil and secondary coil showed the highest insertion loss with 2.5 dB at 280 MHz. Also confirmed that the bandwidth goes up as the number of turns goes down. There was some difference between the actual measured data and the HFSS simulation result. It looks as if it is an error of the difference between oxidation of copper or the permeability of SU-8.

반응표면분석법을 이용한 전도성물질의 절연코팅 프로세스의 최적화 (Optimization of Process Variables for Insulation Coating of Conductive Particles by Response Surface Methodology)

  • 심철호
    • Korean Chemical Engineering Research
    • /
    • 제54권1호
    • /
    • pp.44-51
    • /
    • 2016
  • 전도성 물질인 철 입자(iron particles)를 절연체로 코팅하여 제작한 압분자심(powder core)은 비저항이 작기 때문에 고주파 영역에서 와전류 손실이 크다. 이 결함을 해결하기 위해서는 압분자심의 비저항을 증가시킬 필요가 있다. 이 연구에서는 압분자심의 비저항을 증가시키기 위하여 유성볼밀을 사용하여 전기전도성 철 입자에 산화제2구리를 코팅하였다. 반응표면분석법을 사용하여 코팅변수를 최적화하였다. 최적화 시 인자는 CuO 질량분율, 밀 회전 수, 코팅시간, 볼 크기, 볼 질량, 시료 질량이며, 반응변수는 비저항이었다. 6인자-일부요인배치법에 의하면 주된 인자는 CuO 질량분율, 밀 회전 수, 코팅시간이었다. 3-인자 완전요인배치법과 최대경사법을 사용하여 3개 인자의 수준을 선정하였다. 최대경사법을 사용하여 최고의 비저항을 갖는 영역에 접근하였다. 최종적으로 Box-Behnken법을 사용하여 스크린한 인자들의 반응표면을 분석하였다. Box-Behnken법 결과에 의하면 CuO 질량분율과 밀 회전 수가 코팅공정 효율에 영향을 주는 주요 인자이었다. CuO 질량분율이 증가함에 따라 비저항은 증가하였다. 그에 반해서 밀 회전 수가 감소함에 따라 비저항은 증가하였다. 코팅공정을 최적화한 모델로부터 계산한 예측값과 실험값과는 통계적으로 유의하게 일치하였다($Adj-R^2=0.944$). 비저항의 최고값을 갖는 코팅조건은 CuO 질량분율은 0.4, 밀 회전 수는 200 rpm, 코팅시간은 15분이었다. 이 조건에서 코팅한 정제의 비저항 측정값은 $530k{\Omega}{\cdot}cm$이었다.

Analysis and Correction of Through-bolt End-region Overheating and Breakdown Failure in a Large Tubular Hydro-generator

  • Zhou, Zhi-ting;Fan, Zhen-nan;Li, Jian-fu;Wen, Kun;Zhang, Bide;Wang, Tao;Xia, Yan-kun;Sun, Zhang;Yao, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2292-2300
    • /
    • 2018
  • A field-circuit coupling model of a typical faulty generator is established to correct through-bolt end-region overheating and breakdown failure in a tubular hydro-generator. Using the model, eddy current loss and electromagnetic forces on through bolts under normal and failure conditions are analyzed and compared and the natural frequency of a through bolt is determined. Based on the analysis results, the causative mechanism of failure is revealed and targeted improvement design measures are proposed. The numerical results are found to be consistent with the actual fault characteristics, validating the design measure improvements. The results are useful in improving the design and manufacturing standards and enhancing the operational reliability of large tubular hydro-generators.

600 kJ SMES용 열 전도판의 구조에 따른 와전류 손실 특성 (Eddy Current Loss of the Cooling Plate According to its Shape for 600 KJ SMES)

  • 이상엽;곽상엽;박명진;김우석;이지광;최경달;배준한;김석호;심기덕;성기철;정현교;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.132-133
    • /
    • 2007
  • 본 논문에서는 600kJ급 SMES용 열전도판의 와전류 손실의 해석에 대해서 나타내었다. SMES의 운전 상태는 충전, 운전, 방전의 3가지 구간으로 나누어 볼 수 있다. 이 중 방전 구간에서는 SMES 코일에서의 전류 감소에 의해서 와전류 손실이 발생한다. 이때 발생하는 와전류 손실은 짧은 시간동안 발생하지만 그 크기가 크기 때문에, SMES 시스템 설계 시 냉각 시스템의 효율과 안정성을 위해서 반드시 고려되어야만 한다. 본 논문에서는 이러한 열 전도판의 와전류 손실을 해석하고, 그 형상의 변화에 따른 와전류 손실 값들을 분석하였다.

  • PDF