두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향 (The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT)

  • 엄기천;김가중;백금문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.239-246
    • /
    • 2023
  • In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom's body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

고 에너지 방사선치료 시 GEANT4-DICOM과 TPS간 선량비교 연구 (A Comparative Study on the Dose of GEANT4-DICOM to TPS for High-Energy Radiation Treatment)

  • 곽근탁;김양수;권형철;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.567-572
    • /
    • 2018
  • Radiation therapy is one of the beneficial choices in the treatment of cancer. This is a comparison of TPS(Treatment Planning System) and GEANT4-DICOM, which should be preceded by the best radiation therapy. A treatment plan for prostate cancer was established with Eclipse and the point doses 366.1 cGy, 189.1 cGy, 213.4 cGy, 127 cGy, 105.7 cGy of any five prostate, bladder, rectum, right femoral head and left femoral head were identified. GEANT4-DICOM simulation showed that the results of Eclipse and ${\pm}2%$ dose error were confirmed. The monthly X-ray output agreement management value recommended by TG-142 is ${\pm}2%$, which means that the experimental results can be meaningful. In conclusion, GEANT4-DICOM is an infinite way to obtain more extended dose information once the time constraints are overcome in the simulation.

동적 다엽콜리메이터의 Leaf gap이 전산화 치료계획에 미치는 영향 (The dosimetric impact on treatment planning of the Dynamic MLC leaf gap)

  • 김정미;윤인하;홍동기;백금문
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.233-238
    • /
    • 2014
  • 목 적 : 최근 사용이 급증하고 있는 미국 베리안사의 이클립스 치료계획 시스템은 치료기에 설치되어 있는 다엽콜리메이터의 충돌 보호를 위해 존재하는 하드웨어적 제한성을 립 갭이라는 설정을 통하여 소프트웨어적으로 극복함으로써 정확한 치료계획을 구현 할 수 있도록 한다. 본 연구에서는 이클립스 치료계획 시스템에 설정되어 있는 립 갭이 치료계획에 미치는 영향을 분석하고 정확한 임상적용에 이용할 수 있도록 하고자 한다. 대상 및 방법 : 연구에 사용되어진 이클립스 치료계획 시스템의 버전은 11.0이다. 시스템에 설정되어 있는 립 갭은 각 치료기와 광자 에너지별로 측정되었다. 일반적으로 0.05~0.30 mm의 값을 가지고 있고, 다엽콜리메이터의 교정상태에 따라 다르므로 일괄되게 적용하지 않고 측정를 통하여 적용한다. 본 연구에서는 세기변조와 용적변조 치료계획을 측정된 각각의 립 갭을 적용하고, 립 갭이 달라질 때마다 치료계획의 영향을 Dmax, CI 등을 이용하여 평가하였다. 결 과 : 동일한 치료계획을 각각의 치료기에서 립 갭을 변화하며 평가하였을 때, 립 갭이 0.05 mm ~ 0.50 mm로 증가할수록 Dmax, CI 의 값이 2~5% 이상 증가하였다. 세기변조방사선치료계획과 용적변조방사선치료계획 모두 동일한 경향을 나타내었고 각 치료계획 간의 유의성은 찾아 볼 수 없었다. 결 론 : 치료기의 다엽콜리메이터의 립 갭 설정은 일반적으로 고유한 측정값을 가지고 있다. 하지만, 다엽콜리메이터의 노후, 교정, 수리 및 점검 후에 립 갭은 변할 수 있고, 이러한 값은 결국 치료계획에 영향을 미치기 때문에 반드시 확인 후 치료에 적용해야 한다. 경우에 따라선 립 갭을 초기 설정값을 유지하는 할 수 있는데, 이는 치료계획에 미치는 영향을 무시할 수 있기 때문에 바람직하지 않다.

The Accuracy of the Calculated Dose for a Cardiac Implantable Electronic Device

  • Sung, Jiwon;Son, Jaeman;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.150-154
    • /
    • 2019
  • The objective of this study is to monitor the radiation doses delivered to a cardiac implantable electronic device (CIED) by comparing the absorbed doses calculated by a commercial treatment planning system (TPS) to those measured by an in vivo dosimeter. Accurate monitoring of the radiation absorbed by a CIED during radiotherapy is necessary to prevent damage to the device. We conducted this study on three patients, who had the CIED inserted and were to be treated with radiotherapy. Treatment plans were generated using the Eclipse system, with a progressive resolution photon optimizer algorithm and the Acuros XB dose calculation algorithm. Measurements were performed on the patients using optically stimulated luminescence detectors placed on the skin, near the CIED. The results showed that the calculated doses from the TPS were up to 5 times lower than the measured doses. Therefore, it is recommended that in vivo dosimetry be conducted during radiotherapy for CIED patients to prevent damage to the CIED.

자궁경부암 근접방사선치료 시 2차원, 3차원 치료계획 비교평가 (Comparison of 2D and 3D Brachytherapy Planning for Cervical Cancer)

  • 김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.303-309
    • /
    • 2017
  • 본 연구에서는 자궁경부암의 치료를 위한 전산화단층촬영(computer tomography)영상을 이용한 3차원 근접치료계획의 유용성을 알고자 하였다. 10명의 자궁경부암 환자에서 2차원 근접치료계획을 시행하였고, 동일 자세로 전산화단층촬영을 시행하였다. 3차원 근접치료계획 프로그램(ECLIPSE treatment planning system v6.5, Varian Medical System, USA)를 이용하였으며, 고위험임상표적체적(High risk CTV, HR CTV)에 5 Gy를 처방하였다. 3차원 근접치료계획의 제한은 적어도 고위험임상표적체적의 90%에 처방선량인 5 Gy가 조사되도록, 방광의 $2cm^3$에 7.5 Gy 미만으로 들어가도록 그리고 직장의 $2cm^3$에 5 Gy 미만이 들어가도록 하였다. 계획의 평가는 선량체적표(dose-volume histograms; DVHs)를 이용하여 육안적종양체적(Gross tumor volume for brachytherapy; $GTV_B$), 고위험임상표적체적, 직장과 방광에 조사되는 선량을 구하였다. 크기가 큰 종양이나 자궁의 위치이상이 있는 환자에서 Point A에 처방한 2차원 근접치료계획을 하였을 경우에는 고위험임상표적체적이 충분히 포함되지 않았다. 그러나 3차원 근접치료계획은 이러한 환자들에서 직장이나 방광의 선량을 증가시키지 않고 고위험임상표적체적을 잘 포함할 수 있었다. 2차원 근접치료계획에서 높은 선량부터 $2cm^3$에 들어가는 직장선량은 10명 중 1명에서, $2cm^3$에 들어가는 방광선량은 6명에서 5 Gy를 넘었으므로 ICRU (International Commission on Radiation Units) 방광선량이 직장선량에 비해 과소평가됨을 확인할 수 있었다. 자궁경부암 환자에서 전산화단층촬영 이용한 3차원 근접치료계획은 종양과 위험장기에 대한 선량평가가 가능하므로, 직장과 방광의 부작용을 증가시키지 않으면서 크기가 큰 종양이나 자궁의 위치이상이 있는 환자에서 위치 설정의 오류를 줄일 수 있을 것으로 생각된다.

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

  • Jin, Hosang;Jesseph, Fredrick B.;Ahmad, Salahuddin
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.65-71
    • /
    • 2014
  • A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the Varian Eclipse treatment planning system (TPS). An isocentrically mounted Sun Nuclear MapCHECK 2 diode array with 5 cm water-equivalent buildup was also used for the VMAT QAs and the measurements were compared to a composite dose plane from the Eclipse TPS. A ${\gamma}$ test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison at 1%/1 mm (dose difference/distance-to-agreement), 2%/2 mm, and 3%/3 mm criteria for both QA methods. The two-tailed paired Student's t-test was employed to analyze the statistical significance at 95% confidence level. The average ${\gamma}$ passing rates were greater than 95% at 3%/3 mm using both methods for all four energies. The differences in the average passing rates between the two methods were within 1.7% and 1.6% of each other when analyzed at 2%/2 mm and 3%/3 mm, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1 mm; the difference was lower for 8 MV and 10 MV. However, the differences were not statistically significant for all criteria and energies (p-values >0.05). The EPID-based QA showed large off-axis over-response and dependence of ${\gamma}$ passing rate on energy, while the MapCHECK 2 was susceptible to the MLC tongue-and-groove effect. The two fluence-based QA techniques can be an alternative tool of VMAT QA to each other, if the limitations of each QA method (mechanical sag, detector response, and detector alignment) are carefully considered.

Analysis of Small-Field Dosimetry with Various Detectors

  • Park, So-Yeon;Choi, Byeong Geol;Lee, Dong Myung;Jang, Na Young
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.164-172
    • /
    • 2018
  • We evaluated the performance of various detectors for small-field dosimetry with field sizes defined by a high-definition (HD) multileaf collimator (MLC) system. For small-field dosimetry, diodes referred to as "RAZOR detectors," MOSFET detectors, and Gafchromic EBT3 films were used in this study. For field sizes less than $1{\times}1cm^2$, percent depth doses (PDDs) and lateral profiles were measured by diodes, MOSFET detectors, and films, and absolute dosimetry measurements were conducted with MOSFET detectors. For comparison purposes, the same measurements were carried out with a field size of $10{\times}10cm^2$. The dose distributions were calculated by the treatment planning system Eclipse. A comparison of the measurements with calculations yielded the percentage differences. With field sizes less than $1{\times}1cm^2$, it was shown that most of the percentage difference values were within 5% for 6-MV and 15-MV photon beams with the use of diodes. The measured lateral profiles were well matched with those calculated by Eclipse as the field sizes increased. Except for the depths of 0.5 cm and 20 cm, there was agreement in terms of the absolute dosimetry within 10% when MOSFET detectors were used. There was good agreement between the calculations and measurements conducted using diodes and EBT films. Both diode detectors and EBT3 films were found to be appropriate options for relative measurements of PDDs and for lateral profiles.

동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석 (Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories)

  • 강민영;이보람;김유현;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권1호
    • /
    • pp.51-58
    • /
    • 2011
  • 본 연구의 목적은 회전조사 시 표적종양의 위치변위와 갠트리의 조사반경에 의한 치료깊이 변화에 따른 모의치료계획 결과와 선량전달 결과상의 오차를 분석하고자 하였다. 깊이 변위가 가장 이상적인 경우, 즉 팬텀의 중심에 표적이 위치한 경우와 한쪽으로 2.5 cm, 5 cm씩 치우친 경우로 나누어 모의실험하였다. 표적의 위치 변화에 따른 모의치료계획을 실시하기 위하여 IMRT Body 팬톰(I'mRT Phantom, Wellhofer Dosimetry, Germany)를 이용하여 전산화단층촬영장치(Computed Tomography, Light speed 16, GE, USA)로 데이터를 획득하였다. 획득된 영상을 이용하여 치료계획장치(Treatment Planning System, Eclipse, ver. 6.5, VMS, Palo Alto, USA)를 이용하여 정중앙, 2.5 cm, 5 cm에 가상의 치료표적을 만들어 모의치료계획을 수립하였다. 선형가속기(CL21EX, VMS, Palo Alto, USA)의 6 MV 광자선과 최근 개발된 Gafchromic 필름(EBT2, ISP, Wayne, USA)을 이용하여 선량분포를 측정하였고, 선량분석프로그램(OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany)을 이용하여 모의치료계획 데이터와 측정 데이터를 정량적으로 분석하였다. 분석프로그램으로 횡축방향 선량분포 프로파일(Cross-plane profile)과 선량분포를 정량적으로 분석하기 위하여 감마인덱스(DD: 3%, DTA: 2 mm) 히스토그람을 이용하였다. 표적과 표적주변의 선량분포는 Conformity index(CI), Homogeneity index(HI)를 이용하여 정량적으로 분석하였다. 치료표적 전체체적에 대한 100% 선량분포에 포함되는 체적을 비교하여 분석하였다. 표적의 위치가 5 cm 에 있는 경우 다문동적회전조사(Multiple Conformal Arc Therapy, MCAT)는 23.8%, 단일동적회전조사(Single Conformal Arc Therapy, SCAT)는 35.6%, 고정조사는 37%였고, 표적이 2.5 cm에 있는 경우 MCAT 61%, SCAT 21.5%, 고정조사 14.2%로 분석되었다. 표적의 위치가 중앙에 있는 경우 MCAT 70.5%, SCAT 14.1%, 고정조사 36.3%로 나타났다. 표적의 위치가 5 cm 치우쳐 있는 경우를 제외하고 MCAT의 100% 선량분포에 포함되는 체적이 가장 크게 나타났다. 감마인덱스 히스토그램 분석결과, SCAT의 경우 37.1, 27.3, 29.2로 MCAT의 경우 9.2, 8.4, 10.3에 비해 최소 2.8배, 최대 4배 오차가 크게 나타났다. 결론적으로, 동적조형회전조사 시 표적종양의 위치변이와 조사반경의 변화에 따라 선량전달오류의 가능성을 알 수 있었으며 치료표적의 위치가 정중앙이 아닐 경우, 깊이와 회전반경을 최적화함으로써 정확한 선량 전달을 할 수 있다고 생각한다.

15 MV를 이용한 전립샘암 세기조절 방사선치료 시 빔의 개수에 따른 부작용 발생률에 관한 연구 (A Study on the Incidence of Side Effects according to the Number of Beams in Intensity-modulated Radiation Therapy for Prostate Cancer using 15 MV)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.481-487
    • /
    • 2023
  • 본 연구에서는 15 MV를 이용한 전립샘암의 세기조절방사선치료 시 빔의 개수에 따른 광중성자선량의 부작용 발생률을 분석하고자 한다. 전립샘암 세기조절방사선치료의 방사선치료계획설계는 1회 처방선량 220 cGy, 전체 치료 횟수는 33회로 총 7260 cGy로 수립하였다. 실험에 사용된 선형가속기는 Varian의 True Beam STx(Varian, USA)이며, 계획용 표적체적(Planning target volume; PTV)에 15 MV로 광중성자 선량이 발생되도록 하였다. 치료계획의 설계는 Eclipse System (Varian Ver 10.0, USA)을 사용하여 세기조절방사선치료 5, 7, 9 portals로 하였다. 광중성자 선량 측정을 위해 광자극발광선량계 (Optically stimulated luminescence albedo neutron dosimeter, Landauer Inc., USA)를 사용하였다. 세기조절방사선치료 5 portals 시 1,000명당 1.7명, 7 portals 시 1,000명당 1.8명, 9 portals 시 1,000명당 2.0명이 광중성자 선량으로 인하여, 갑상샘에 부작용을 나타낼 확률임을 산출하였다. 본 연구는 세기조절방사선치료 시 2차 피폭선량의 위험성을 연구하여, 향후 방사선의 확률적 영향과 관련된 의미 있는 자료로 활용될 수 있기를 기대한다.

Acute Toxicity in Nasopharyngeal Carcinoma Patients Treated with IMRT/VMAT

  • Ozdemir, Sevim;Akin, Mustafa;Coban, Yasin;Yildirim, Cumhur;Uzel, Omer
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.1897-1900
    • /
    • 2015
  • Purpose: To evaluate acute toxicity in nasopharyngeal cancer (NPC) patients treated with intensity modulated radiotherapy (IMRT)/volumetric modulated arc therapy (VMAT) with or without cisplatin-based chemotherapy. Materials and Methods: A total of 45 newly diagnosed, histologically proven non-metastatic NPC patients treated with IMRT between May 2010 and December 2012, were evaluated retrospectively, 37 planned with Eclipse and 8 with Prowess Panther treatment planning system. The doses to the planning target volumes of primary tumor and involved lymph nodes, high risk region, and uninvolved regional nodal areas were 70 Gy, 60 Gy, and 54 Gy respectively and delivered simultaneously over 33 fractions to 39 patients. Another 6 patients irradiated with sequential boost technique. Some 84.4% of patients received chemotherapy. Acute toxicities were graded according to the Radiation Therapy Oncology Group scoring criteria and Common Terminology Criteria for Adverse Events (CTCAE) for chemotherapy side effects. Results: Median age was 43 years (14-79) and all patients were WHO type II. Grade 1 mucositis and dysphagia were observed in 17 (37.8%), and 10 (22.2%) patients, respectively. The incidence of acute grade 2 mucositis and dysphagia was 55.6% and 68.9%, respectively. The most common chemoradiotherapy related acute toxicities were nausea, leucopenia and thrombocytopenia. Grade 3 toxicity was detected in 13 (28.8%) cases. No grade 4 toxicity was occurred. Mean weight loss was 9%. None of the patients required the insertion of percutaneous endoscopic gastrostomy for nutritional support. Radiation therapy was completed without interruption in all patients. Conclusions: IMRT is a safe and effective treatment modality, and well tolerated by patients in the treatment of nasopharyngeal carcinoma. No unexpected side effects were observed.