• Title/Summary/Keyword: Echo signal

Search Result 474, Processing Time 0.028 seconds

An Analysis of Pulse Length Effect on Underwater Simulated Target Strength Estimated Model (수중 모의표적 강도예측 모델의 펄스길이 효과 고찰)

  • 김부일;박명호;권우현
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.44-51
    • /
    • 2001
  • This Paper the practical echo signal synthesis model to predict the target strength and signal shape of a submarine for a valuable tool to active sonar engineer. It is based on UTAHID (Underwater TArget by Highlight Distribution) model which is relocated highlight points along to external hull for aspect angle, and synthesized echo signal by modified grouping highlights to internal scatter cloud. Proposed model is analyzed target strength characteristics on various incident pulse length, and synthesis signal signature, target time spreading loss, echo elongation effect and so on. Thus it can be efficiently used in various real systems related to underwater target echo signal synthesis, that is, active sonar, acoustic countermeasure and surveillance system.

  • PDF

An Analysis of Highlight Distribution Modeling for High Frequency CW Pulse Signal Reflection on Underwater Target (수중표적의 고주파수 CW 펄스신호 반사를 위한 하이라이트 분포 모델링 해석)

  • 김부일;이형욱;박명호;권우현
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.3
    • /
    • pp.1-11
    • /
    • 2000
  • This paper proposes the practical echo-signal synthesis models - UTAHID (Underwater TArget by Highlight Distribution) & M-UTAHID(Modified UTAHID) - of underwater target for active sonar engineering At high frequencies all the echo components that are the specular reflected waves and various elastic scattering wave scan be regarded the summation of individual echo from some equivalent scattering centers, so the underwater target is characterized by highlights distributed in spatial target structure. Proposed models are compared with characteristics of random distributed model & equivalent interval highlight model, and analyzed target strength, echo-elongation effect, target time spread loss and so on. Thus these can be efficiently used in various real systems related to underwater target echo-signal synthesis on active sonar and acoustic countermeasure.

  • PDF

Convergence Analysis of a Stereophonic Echo Canceling Algorithm Using Input Signals of All Channels

  • Kim, Masanori oto;Toshihiro Furukawa;Shinsaku Mori
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.2004-2007
    • /
    • 2002
  • In the linear combination type stereophonic echo canceller, it is known not to converge the coefficient vector of the adaptive filter to a correct echo path. In this report, we analyze the convergence value of the filter coefficient vector of the stereo echo canceling algorithm using input signals of all channels in relation to this problem. In this analysis, one of the two inputs to the un-known system and adaptive one are assumed to be a delayed and attenuated version of the other signal as a model of the input signal with a strong cross-correlation. As a result, it is shown for the coefficient vectors not to converge to echo paths, and nor to converge to the value which depends on the time delay and the attenuation of the input signal. We show that the computer simulation result are corresponding to our analytical results.

  • PDF

Fat Quantification in the Vertebral Body: Comparison of Modified Dixon Technique with Single-Voxel Magnetic Resonance Spectroscopy

  • Sang Hyup Lee;Hye Jin Yoo;Seung-Man Yu;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.126-133
    • /
    • 2019
  • Objective: To compare the lumbar vertebral bone marrow fat-signal fractions obtained from six-echo modified Dixon sequence (6-echo m-Dixon) with those from single-voxel magnetic resonance spectroscopy (MRS) in patients with low back pain. Materials and Methods: Vertebral bone marrow fat-signal fractions were quantified by 6-echo m-Dixon (repetition time [TR] = 7.2 ms, echo time (TE) = 1.21 ms, echo spacing = 1.1 ms, total imaging time = 50 seconds) and single-voxel MRS measurements in 25 targets (23 normal bone marrows, two focal lesions) from 24 patients. The point-resolved spectroscopy sequence was used for localized single-voxel MRS (TR = 3000 ms, TE = 35 ms, total scan time = 1 minute 42 seconds). A 2 × 2 × 1.5 cm3 voxel was placed within the normal L2 or L3 vertebral body, or other lesions including a compression fracture or metastasis. The bone marrow fat spectrum was characterized on the basis of the magnitude of measurable fat peaks and a priori knowledge of the chemical structure of triglycerides. The imaging-based fat-signal fraction results were then compared to the MRS-based results. Results: There was a strong correlation between m-Dixon and MRS-based fat-signal fractions (slope = 0.86, R2 = 0.88, p < 0.001). In Bland-Altman analysis, 92.0% (23/25) of the data points were within the limits of agreement. Bland-Altman plots revealed a slight but systematic error in the m-Dixon based fat-signal fraction, which showed a prevailing overestimation of small fat-signal fractions (< 20%) and underestimation of high fat-signal fractions (> 20%). Conclusion: Given its excellent agreement with single-voxel-MRS, 6-echo m-Dixon can be used for visual and quantitative evaluation of vertebral bone marrow fat in daily practice.

Acoustic Echo Cancellation using Time-Frequency Masking and Higher-order Statistics (시간-주파수 마스킹과 고차 신호 통계를 이용한 음향 반향신호 제거)

  • Kim, Kyoung-Jae;Nam, Sang-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.629-631
    • /
    • 2007
  • In hands-free full-duplex communication systems, acoustic signals picked up by the microphones can be mixed with echo signals as well as noises, which may result in poor performance of the corresponding communication system. Also, the system performance may decrease further if the reverberation occurs since it is harder to estimate the impulse response of the demixing system. For blind source separation (BSS) in such cases, a time-frequency masking approach can be employed to separate undesired echo signals and noises, but, permutation ambiguities also should be solved for the echo cancellation. In this paper, we propose a new acoustic echo cancellation (AEC) approach utilizing the time-frequency masking and higher-order statistics, whereby a desired signal selection, based on coherence and third-order statistics (i.e., kurtosis), is introduced along with output signal normalization. Simulation results demonstrate that the proposed approach yields better echo and noise cancellation performances than the conventional AEC approaches.

Separation of Spectrally Overlapped Broadband Acoustic Scattering Signals from Japanese Needlefish Hypohamphus sajori Using the Fractional Fourier Transform (분수차 푸리에 변환을 이용한 스펙트럼상에서 중첩된 학공치(Hypohamphus sajori)의 광대역 음향산란신호의 분리)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.2
    • /
    • pp.195-206
    • /
    • 2022
  • The separation of spectrally overlapped broadband echo signals from free-swimming Japanese needlefish Hypohamphus sajori using the fractional Fourier transform (FrFT) was investigated. The broadband echo signals were measured over frequency ranges of 40-80 and 110-220 kHz. The overlapped echo signals were separated after eliminating noise signals in the smoothed pseudo-Wigner-Ville distribution domain. The echo signal from a 40 mm WC sphere suspended just below a chirp transducer was used to calibrate the broadband of the chirp echo sounder and estimate the frequency dependence of target strength for the separated echo signals. The experimental results show that the proposed FrFT method can analyze the time-frequency image of broadband echo signals from free-swimming individual fish effectively and can be used as a quantitative tool for extracting the acoustic features used for fish species identification.

Double Talk Detection using the Fuzzy Inference (퍼지 추론을 이용한 동시통화 검출)

  • 류근택;배현덕
    • Journal of Broadcast Engineering
    • /
    • v.5 no.1
    • /
    • pp.123-129
    • /
    • 2000
  • This paper addresses a new double detection algorithm which is based on the fuzzy control in the adaptive echo canceller of communication system. In this method, the two input of the fuzzy inference for detecting double talk condition are used. The one is the cross-correlation coefficient between the error signal and the primary signal which is the summed signal of the real echo signal and the near-end signal. The other is the cross-correlation coefficient between the estimation error signal and the primary signal. The fuzzy controller made a fuzzification for two inputs by the membership functions of trapezoid and them became the composition using inference rules. The composed result is defuzzificated by the center gravity method. The output is compared with two threshold values to detect double talk and echo path variation effectively. It is confirmed by computer simulation that this fuzzy double talk detector is able to track echo path variation accurately.

  • PDF

A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study (3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.253-259
    • /
    • 2015
  • The information of contrast media concentration on target organ is very important to get reduce the side effect and high contrast imaging. We investigated alternation of signal intensity as a function of the modality of Gd-based contrast media on spin echo and ultra short time echo (UTE) of T1 effective pulse sequence at 3T MRI unit. Gadoxetic acid, which is a MRI T1 contrast medium, was used to manufacture an agarose phantom diluted in various molarities, and sterile water and agarose 2% were used as the buffer solution for the dilution. The gold standard T1 calculation was based on coronal single section imaging of the phantom mid-point with 2D Inversion recovery spine-echo pulse sequence MR imaging for testing of phantom accuracy. The 1-2mmol/L and 7mmol/L was shown the maximum signal intensity on spin echo and UTE respectively. We confirm the difference of contrast media concentration which was shown the maximum signal intensity depending on the T1 effective pulse sequence.

Acoustic Echo Cancellation Based on Convolutive Blind Signal Separation Method (Convolutive 암묵신호분리방법에 기반한 음향반향 제거)

  • Lee, Haeng-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.979-986
    • /
    • 2018
  • This paper deals with acoustic echo cancellation using blind signal separation method. This method does not degrade the echo cancellation performance even during double-talk. In the closed echo environment, the mixing model of acoustic signals is multi-channel, so the convolutive blind signal separation method is applied and the mixing coefficients are calculated by using the feedback model without directly calculating the separation coefficients for signal separation. The coefficient update is performed by iterative calculations based on the second-order statistical properties, thus estimates the near-end speech. A number of simulations have been performed to verify the performance of the proposed blind signal separation method. The simulation results show that the acoustic echo canceller using this method operates safely regardless of the presence of double-talk, and the PESQ is improved by 0.6 point compared with the general adaptive FIR filter structure.

A Comparative Analysis of Target Strength Estimated Models for Underwater Echo Signal Synthesis (수중 반사신호 합성을 위한 표적강도 예측모델 비교분석)

  • 김부일
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.93-103
    • /
    • 2001
  • A reflection signal in an active sonar using a high frequency is mainly formed of a specular reflection from the surface of an object along with several equivalent scatters inside, which are characterized by the spatial distribution of the highlight on the object. This study analyze the existing echo signal synthesis models eq, random distribution model, equivalent interval distribution model & MUTAHID(Modified Underwater TArget by HIlight Distribution) model for simulated target, and compare the characteristics of the reflected signal synthesis results for each model in various conditions. These highlight distribution models can be efficiently applied to the simulated target signals synthesis of various real systems requiring the echo signal synthesis on the underwater target.

  • PDF