• 제목/요약/키워드: Echo shape

검색결과 60건 처리시간 0.024초

Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy (자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광)

  • 문치웅;조경식
    • Journal of Biomedical Engineering Research
    • /
    • 제16권4호
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

A Comparative Study of Pulse-echo Method and TOFD Method for the Defect in the Welding Joint of the STS304 Stainless Steel (STS304 스테인리스강 용접부 결함평가에 대한 Pulse-echo법과 TOFD법의 비교연구)

  • Kil, Doo-Song;Choi, Won-Doo
    • Journal of Power System Engineering
    • /
    • 제6권4호
    • /
    • pp.68-72
    • /
    • 2002
  • For the evaluation of a flaw in a welded stainless steel by the Time of Flight Diffraction(TOFD) Method, we have made the reference specimen for experimentation. As a result, we could analyze a specific character and the inner state of the structure in a welded stainless steel and we came to the conclusion as followed. (1) For analyze the structure state of a section in a welded stainless steel through the optical microscope, we could have analyzed the generated shape and the location of a flaw and the inner parts of the structure state through the microscope of eighty magnification and two hundred magnification about the soundness, the heat affected zone(HAZ) and the welded part. (2) Through the comparison with the shape and the size of a flaw in the welded part about the conventional ultrasonic test and the TOFD Method, we could make an observation the special character of the TOFD Method and principles. (3) We analyzed and collected the merit of the TOFD Method on the basis of the experimental result by the shape and the size of a flaw in the inner welded parts. So, we made up a base that we could use as a basic data for a similar flaw like that. Through the study as mentioned above, we could make an observation the flaw detective method and principles used in the TOFD Method.

  • PDF

Applicability Evaluation of Multi Beam Echo Sounder for Inland Water (다중빔 음향측심기의 내수면 적용성 평가)

  • Jung, Jin Woo;Cho, Kwang Hee;Hong, Seung Seo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제36권6호
    • /
    • pp.629-639
    • /
    • 2018
  • In this study, the application of the single beam echosounder and multi beam echosounder was analyzed for the Youngsan river, from the Juksanbo to the Juksan bridge, length of 840m, width 230m and area $0.16km^2$. A single beam echosounder and a multi beam echosounder are mounted on an USV (Unmanned Surface Vessel), and each data is acquired. Then, TIN (Triangular Irregular Network) is created and the grid depth of 10m intervals is extracted. The grid depth of the single beam echo sounder and the grid depth of the multi beam echo sounder were overlapped to compare the two data. As a result of analysis using 5,024 data, the mean depth difference was 0.0319m and the standard deviation was 2.4095m. The river bed shape was similar to each other. If the multi-beam echo sounder is regarded as the standard, the volume difference of the stream is $161,882m^3$. With a multi-beam echo sounder installed, the operating distance increased by approximately 55% to 4595.85m, and the operating time increased by approximately 59% to approximately 47%.

Late Quaternary Sedimentary Processes in the Northern Continental Margin of the South Shetland Islands, Antarctica (남극 남쉐틀랜드 군도 북부 대륙주변부의 후기 제 4기 퇴적작용)

  • 윤석훈;윤호일;강천윤
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • 제9권1호
    • /
    • pp.1-12
    • /
    • 2004
  • Sedimentary facies and high-resolution echo facies were analyzed to elucidate sedimentation pattern of the late Quaternary glacial-marine deposits in the northern continental margin of the South Shetland Islands. Six sedimentary facies are classified, based on grain texture and sedimentary structures in gravity cores. The high-resolution (3.5 ㎑) echo characters are classified into 6 echo facies on the basis of clarity, continuity, and shape of bottom and subbottom echoes together with seafloor topography. Distribution of the echo and sedimentary facies suggest that there was a significant change in sedimentation pattern between the Last Glacial Maximum (LGM) and subsequent glacier-retreating period. When the grounded glaciers extended to the present shelfbreak during LGM, coarse-grained subglacial tills were widespread in the shelf area, and deep troughs in the shelf were carved beneath the fast-flowing ice steam. As the glacial margin retreated landward after LGM, dense meltwater plumes released from the retreating ice-front were funneled along the glacier-carved troughs, and accumulated channel- or cannyon-fill deposits in the shelf and the upper to mid slope. At that time, slope sediments seem to have been reworked by slope failures and unsteady contour currents, and further transported by fine-grained turbidity currents along the South Shetland Trench. After the glacial retreat, sediments in the shelf and slope areas have been mainly introduced by persistent (hemi) pelagic settling, and fine-grained turbidity currents frequently occur along the axis of the South Shetland Trench.

Use of Sonography in the Differential Diagnosis between Phylloides Tumor and Giant Fibroadenoma (엽상육종과 거대 섬유선종의 초음파 소견의 비교)

  • Choi, Jong-O;Kim, Jae-Woon;Park, Won-Kyu;Hwang, Mi-Soo;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • 제13권2호
    • /
    • pp.295-301
    • /
    • 1996
  • Phylloides tumor is very similar to giant fibroadenoma in that they have benign appearance in breast radiologic image. Fibroadenoma has no malignant potential, but phylloides tumor is locally recurrent, invasive and may occasionally metastasize. It thus appears that evaluation of the differential point of the two tumor groups by radiologic study is very important. We retrospectively compared sonographic findings of 6 cases of phylloides tumor with those of 4 cases of fibroadenoma, which proved pathologically in Yeungnam University Hospital from 1984 to 1986. The mean age of the patients were 31.8 years old(from 14 to 41 years old) in phylloides tumor and 28.8 years old (from 17 to 40 years old) in giant fibroadenoma, respectively. The viewpoints of this analysis were size, shape and contour of the masses, internal echo pattern, posterior enhancement, and especially the existence of peripheral cyst or septal band echo. We found that diffenentiation of these two tumors by sonography was difficult. But peripheral cyst was found only in phylloides tumor and septal band echo was found largely in giant fibroadenoma. Although the existence of peripheral cyst or septal band echo in the breast mass was not pathognomonic findings, we suggest that the existence of septal band echo is preferential finding to fibroadenoma, and peripheral cyst is preferential finding to phylloides tumor.

  • PDF

Target Signal Simulation in Synthetic Underwater Environment for Performance Analysis of Monostatic Active Sonar (수중합성환경에서 단상태 능동소나의 성능분석을 위한 표적신호 모의)

  • Kim, Sunhyo;You, Seung-Ki;Choi, Jee Woong;Kang, Donhyug;Park, Joung Soo;Lee, Dong Joon;Park, Kyeongju
    • The Journal of the Acoustical Society of Korea
    • /
    • 제32권6호
    • /
    • pp.455-471
    • /
    • 2013
  • Active sonar has been commonly used to detect targets existing in the shallow water. When a signal is transmitted and returned back from a target, it has been distorted by various properties of acoustic channel such as multipath arrivals, scattering from rough sea surface and ocean bottom, and refraction by sound speed structure, which makes target detection difficult. It is therefore necessary to consider these channel properties in the target signal simulation in operational performance system of active sonar. In this paper, a monostatic active sonar system is considered, and the target echo, reverberation, and ambient noise are individually simulated as a function of time, and finally summed to simulate a total received signal. A 3-dimensional highlight model, which can reflect the target features including the shape, position, and azimuthal and elevation angles, has been applied to each multipath pair between source and target to simulate the target echo signal. The results are finally compared to those obtained by the algorithm in which only direct path is considered in target signal simulation.

An Ultrasonic Measurement Model to Predict a Reflected Signal from Non-Linear Burning Surface of Solid Propellants

  • Song, Sung-Jin;Kim, Hak-Joon;Oh, Hyun-Taek;Lee, Sang-Won;Song, Seung-Hyun;Kim, In-Chul;Yoo, Ji-Chang;Jung, Jung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제27권6호
    • /
    • pp.531-540
    • /
    • 2007
  • While determination of the solid propellant burning rates by ultrasound, it has been reported that the frequent data scatters were caused by two major factors; 1) variation in the acoustical properties, and 2) non-linear burning of a solid propellant sample under investigation. This work is carried out for the purpose of investigating the effect of non-linear burning of solid propellant samples. Specifically, we propose an ultrasonic measurement model that can predict the reflections from solid propellant surfaces with non-linear burning by the combination of two ingredients; 1) a pulse-echo ultrasonic measurement model for a planar, circular reflector imbedded in the second medium in an immersion set-up, and 2) an efficient model of non-linear burning surfaces with a number of small, planar circles. Then, we demonstrate the capability of the proposed measurement model by simulation of the surface echo signals from four different burning surfaces that have been generated by the combination of two factors; the base shape (flat or paraboloidal) and the surface roughness (perfectly smooth or randomly rough). From the simulation presented here, we can confirm the fact that the non-linear burning of the propellant can cause the waveform change of the burning surface echo and the corresponding spectrum variation.

Performance Analysis of OFDM Communication Systems Considering PDP of Mobile Channels (이동통신 채널의 PDP에 따른 OFDM 통신 시스템의 성능 분석)

  • Lee, Jong-Gil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제9권6호
    • /
    • pp.1182-1188
    • /
    • 2005
  • In this paper, various power delay profiles (PDP) are simulated to study the influence of the PDP shape on the bit error rate (BER) performance of Orthogonal Frequency Division Multiplexing (OFDM) communication systems. Assuming Rayleigh fading with 16-QAM modulation scheme, the simulation focuses on the investigation of the various shapes of the PDP which are often characterized by peaks, slope, attenuation and distance of an echo profile of waves. This yields information about the properties of the channel, and can be applied to decide the performance of the systems according to the channel.

Radiologic Findings of Cervical Mass Type Cervical Pregnancy (자궁경부 종괴형 자궁경부임신의 영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • 제22권1호
    • /
    • pp.43-51
    • /
    • 2005
  • Background: To examine the ultrasonographic and magnetic resonance (MRI) imaging findings of a cervical mass type cervical pregnancy. Materials and Methods: The ultrasonographic and MRI findings of 5 patients pathologically confirmed as having a cervical pregnancy were analyzed retrospectively. On ultrasonography, the size and echo pattern of the uterine cervix, the shape and echo pattern of the lesion, the degree and the pattern of blood flow on the color Doppler study and the spectral Doppler pattern were analyzed. The shape, signal intensity, and degree and pattern of enhancement of the lesion were evaluated on MRI. Results: The uterine cervix was enlarged and the size of the lesion was 6.1 to 7.1 (average, 6.5) cm. The endocervical canal was irregularly dilated and showed heterogeneous echogenicity in all 5 cases. Four of the 5 lesions were heterogeneously hyper- or mixed echoic and remaining one was relatively homogeneous echogenic. Doppler ultrasonography revealed an increased vascularity of the peritrophoblastic flow pattern. In all 4 cases where MRI performed, the lesion was irregular in shape and the margin was not sharply demarcated. The T2-weighed image showed that the lesions were mixed signal intensity. Three of the 4 lesions contained high signal intensity nodular portions and a low signal intensity rim was observed along the margin of the nodular portions. The T1-weighted image revealed multiple signal voids along the periphery of the lesions and high signal intensity portions as a result of hemorrhage were noted. The dynamic enhanced study showed that the high signal intensity portions on the T2-weighted image were strongly enhanced similar to the vessels on the early phase and the contrast enhancement gradually decreased with time. Conclusion: A cervical mass type cervical pregnancy can be correctly diagnosed using the patient's clinical symptom, the elevation in the serum ${\beta}$-HCG level, and characteristic ultrasonographic and MRI findings.

  • PDF

WiFi(RLAN) and a C-Band Weather Radar Interference

  • Moon, Jongbin;Ryu, Chansu
    • Journal of Integrative Natural Science
    • /
    • 제10권4호
    • /
    • pp.216-224
    • /
    • 2017
  • In the terrain of the Korean peninsula, mountainous and flat lands are complexly distributed in small areas. Therefore, local severe weather develops and disappears in a short time due to the influence of the terrain. Particularly in the case of local severe weather with heavy wind that has the greatest influence on aviation meteorology, the scale is very small, and it occurs and disappears in a short time, so it is impossible to predict with fragmentary data alone. So, we use weather radar to detect and predict local severe weather. However, due to the development of wireless communication services and the rapid increase of wireless devices, radio wave jamming and interference problems occur. In this research, we confirmed through the cases that when the radio interference echo which is one of the non-precipitation echoes that occur during the operation of the weather radar is displayed in the image, its form and shape are shown in a long bar shape, and have a strong dBZ. We also found the cause of the interference through the radio tracking process, and solved through the frequency channel negotiation and AP output minimizing. The more wireless devices increase as information communication technology develops in the future, the more emphasized the problem of radio wave interference will be, and we must make the radio interference eliminated through the development of the radio interference cancellation algorithm.