• Title/Summary/Keyword: Earthing

Search Result 76, Processing Time 0.022 seconds

A Study on the Earthing System of Using Discharge Electrodes (방전전극을 사용한 접지시스템에 관한 연구)

  • Seol, Dong-Hwa;Kim, Myeong-Saeng;Kim, Chang-Bong;Woo, Jea-Wook
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.2
    • /
    • pp.84-89
    • /
    • 2009
  • This paper has purpose of designing the earthing system installed on the ground without laying under the ground. As a solution for green IT environment to solve the existing earthing system, the third generation earthing machine was designed by using discharge electrodes, catalyzer, and hot wires. As a result of comparison, it found that the third generation earthing system suggested in this research had more increased discharge currents by 31[A] and the speed 25 times faster than the second generation earthing system. The suggested earthing system is allowed to be installed on the ground and solve construction costs, time, area, and environment pollution, which are problems in the existing earthing system. In addition, as the earthing technique has recently developed, the earthing system is classified by generation based on capacity.

  • PDF

Anti-inflammatory Effects of Earthing Mattress in Mouse (Balb/c 생쥐에 대한 어싱 매트리스에 의한 항염 효과)

  • Kim, Ji Youn
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.89-93
    • /
    • 2022
  • Earthing, caused by direct skin contact with the Earth's surface, is used to reduce the symptoms of inflammation (fever, fever, swelling and pain). However, there is little evidence to support the anti-inflammatory effects of earthing mattresses. Therefore, this study was conducted to investigate whether anti-inflammatory effect of earthing mattress using an in vivo animal model. The anti - inflammatory effect was evaluated by measuring ear thickness and foot volume in 12-O-tetradecanoylphorbol-13 acetate (TPA) - induced ear edema and carrageenan - induced paw edema model, respectively. Balb/c mouse in carrageenan paw edema model showed significant anti - inflammatory effect in the group treated with earthing mattress for 4 hours or 24 hours for 3 days. For females, the anti-inflammatory effect was greater when the earthing mattress was added to the mattress than the mattress alone treatment. From the above results, it was found that the female responds more to the effect of the earthing as well as the mattress effect. In addition, when the male and female Balb/c mice were exposed to mattresses and earthing mattresses for 24 h for 3 days, respectively, the mattress and earthing mattresses showed significant inhibition of IL (Interleukin)-1β levels compared to the control. In the TPA ear edema model, Balb/c mouse showed significant anti - inflammatory effect in the group treated with the earthing mattress for 4 hours or 24 hours for 3 days. Both males and females showed more anti-inflammatory effects when they were exposed to earthing mattresses with mattresses added to the mattresses. From the above results, it was found that both male and female respond to the effect of earthing as well as the mattress effect in the TPA ear edema model. In conclusion, in this study, we have verified that earthing mattress shows inhibitory effects on TPA and carrageenan-induced inflammation. From these results, it is suggested that the anti-inflammatory effect can be expected by applying the earthing mattress to patients suffering from inflammatory diseases. However, there is a need to pinpoint exactly how the earthing mattress relieves inflammation, and further research is needed to investigate the mechanism.

The Design Flowchart of Earthing System for Building Electrical Installations in Accordance with International Standards (국제표준에 따른 건축전기설비의 접지시스템 설계순서)

  • Lee, Ju-Cheol;Yeom, Jin-Geun;Jeong, Seung-Hyun;Byeon, Cheol-Gyun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.113-120
    • /
    • 2014
  • In this paper, designing of an earthing system in accordance with international standards with regard to 22.9kV-y multi-grounded neutral system is discussed and confirmed that the consumer's earthing system can be a part of a global earthing system by interconnecting its earthing system with the neutral conductor of 22.9kV-y multi-grounded system. Further, it is proposed that some modification of the earthing system design flowchart given in the international standards are necessary when considering the equipotential bonding, lightning protection, and telecommunications facilities as well as the basic safety requirements.

A Consideration of Volume and Installation Method of Concrete-Embedded Foundation Earthed an Electrode (콘크리트에 매입된 기초접지극의 크기 및 설치방법에 관한 고찰)

  • Lee, Ju-Cheol;Lee, Young-Chul;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.82-88
    • /
    • 2013
  • IEC standards do not require to limit the earthing resistance of the concrete-embedded foundation earthing electrode which is installed to a specific value. However, in Korea the value of $5{\Omega}$ and below applies to the earthing resistance for a domestic customer whose receiving voltage is 22.9kV. This paper calculates the minimum area and volume of the concrete-embedded foundation earthing electrode in order to obtain a specific value of the earthing resistance when the electrode of the building's lightning protection system and that of its power system are interconnected. It also suggested the most appropriate method of installing the foundation earthing electrode, taking the electric characteristics of concrete into account.

A study on an earthing system without ground connection (대지에 매설할 필요가 없는 접지시스템에 관한 연구)

  • Seol, Dong-Hwa;Kim, Chang-Bong;Woo, Jea-Wook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.258-261
    • /
    • 2009
  • This paper proposes an earthing system without ground connection. As a Green IT Environmental Solution, Internal-external surge and other unnecessary electric currents are converted into energy and through a discharge the signal is reduced. It's a structure that discharges through a neutral electric transformer. The results show that the electric potential rising of the earthing system proposed in this paper are approximately below the half and the discharge currents increased approximately 9 times when compared to existent earthing systems. This earthing system is economical, easy to install and can solve environmental contamination.

  • PDF

A Study on the Earthing System (접지시스템에 관한 연구)

  • Seol, Dong-Hwa;Kim, Myeong-Saeng;Kim, Chang-Bong;Woo, Jea-Wook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.375-378
    • /
    • 2009
  • This paper will arrange and classify the earthing system by the latest developed technique tendency, and suggest how to solve the problem of a current earthing system. The 3rd generation earthing system is environment-friendly and designed to use discharge electrodes, catalysts and heat rays. A discharge current has increased by 31 [A] in the 3rd generation of earthing system compared to the 2nd one and it is 25 times faster. This system is not buried under but built on the ground. It solves the problems that the current system has; expenses, time, area and pollutions followed by the construction.

  • PDF

Study on the effective earthing method in underground section of railways (철도 지하구간에 대한 효율적인 접지방안에 대한 연구)

  • Kim Yang-Soo;Kim Jae-Moon
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.767-775
    • /
    • 2005
  • Power Supply System for electric railways is diversified with technical development and is required high technologies. especially, recently there is required many research and development for earthing to ensure safety of people and protection of installations. Generally, leakage resistance is high between rail and ground at tunnel section of subway. because of short circuit of feeding line, earthing interference by transient overvoltage between signals and communication system, and insulation failure, it can damage to human and equipments To minimize these obstacles, earthing equipment is installed at underground section of railway, but it brings about problems in accordance with operate each earthing system to be not enough required protection provisions for electrified railways. This paper proposes effective earthing method to be concerned about installation cost and maintenance. The validity of the proposed earth method is verified by simulation results at underground section of railways.

  • PDF

The Comparison and Analysis about Earth Resistance for Measuring of Earth Resistance by Measurement Positions of Auxiliary Poles (접지저항 측정을 위한 보조전극 위치에 따른 접지저항 비교 분석)

  • Han, Woon-Ki;Jung, Jin-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.128-133
    • /
    • 2009
  • This paper describes the comparison and analysis about measurement method of earthing resistance by positions of potential pole and current pole. In KOREA, a diagonal by 6.5 times of earthing electrode for measurement of earthing resistances but this method was almost impossible in the downtown area. For solving this problem, in this paper measuring of earthing resistance changing parameters. The parameter was a distances of earthing electrode, potential pole & current pole and the another parameter was an angles of potential pole & current pole. Analysis result, earthing resistance stability that conditions. Fist, distance from earthing electrode to current pole was over 50[m] and distance from earthing electrode to potential pole was over 30[m]. Second, angles of potential pole & current pole was over $45[^{\circ}]$.

Optimization of the Earthing Resistance and Research on the Electrical Characteristics of New Catalyst for the Quality Earthing (접지품질 개선을 위한 접지저항 최적화 및 접지충진제의 전기적 특성 연구)

  • Park, C.G.;Ahn, S.J.;Woo, J.W.;Ahn, S.J.;Yu, Y.J.;Ahn, S.J.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1078-1085
    • /
    • 2006
  • In earthing technologies, the intrusion of the surge wave can be protected when the earthing resistance is as low as several ohms. However, the cost fer realizing such a low resistance is quite high. Therefore it is important to determine appropriate target value of the earthing resistance to install cost-effective grounding system. In this work, we have proposed an optimization method of the earthing resistance according to the various environmental parameters by using a numerical simulator We have also developed new catalyst composed of water-soluble alkaline elements and activated carbon and investigated its electrical characteristics for enhancement of the earthing qualities.

  • PDF

Review of the earthing method of the copper wire shield of 66kV feeder cable in tunnel area (터널 구간 66kV 급전선 차폐층 접지 시공 방법에 관한 검토)

  • Kwon Sam-Young;Kim Do-Won;Ahn Young-Boon;Park Hyun-Jun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1474-1479
    • /
    • 2004
  • In electrification of the Honam line, the grounding method of the copper wire shield of 66kV feeder cable was disputed. This paper describes that the review of the proper earthing method(one-side earthing or both-side earthing) under consideration of the site condition and the acceptability of the induction voltage of the shield on the end of the cable.

  • PDF