• Title/Summary/Keyword: Early 전압

Search Result 49, Processing Time 0.027 seconds

Fast locking single capacitor loop filter PLL with Early-late detector (Early-late 감지기를 사용한 고속 단일 커패시터 루프필터 위상고정루프)

  • Ko, Ki-Yeong;Choi, Yong-Shig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.2
    • /
    • pp.339-344
    • /
    • 2017
  • A novel structure of phase locked loop (PLL) which has small size and fast locking time with Early-late detector, Duty-rate modulator, and Lock status indicator (LSI) is proposed in this paper. The area of loop filter usually occupying the larger portion of the chip is minimized using a single small capacitor. While the conventional PLL with a single capacitor loop filter cannot work stably, the proposed PLL with two charge pumps works stably because the output voltage waveform of the proposed a single capacitor loop filter is the same as the output voltage waveform of the conventional 2nd-order loop filter. The two charge pumps are controlled by the Early-late detector which detects early-late status of UP and DN signals, and Duty-rate modulator which generates a steady duty-rate signal. Fast locking time is achieved using LSI. It has been simulated and proved by HSPICE in a CMOS $0.18{\mu}m$ 1.8V process.

Degradation of the SiGe hetero-junction bipolar transistor in SiGe BiCMOS process (실리콘-게르마늄 바이시모스 공정에서의 실리콘-게르마늄 이종접합 바이폴라 트랜지스터 열화 현상)

  • Kim Sang-Hoon;Lee Seung-Yun;Park Chan-Woo;Kang Jin-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.1
    • /
    • pp.29-34
    • /
    • 2005
  • The degradation of the SiGe hetero-junction bipolar transistor(HBT) properties in SiGe BiCMOS process was investigated in this paper. The SiGe HBT prepaired by SiGe BiCMOS process, unlike the conventional one, showed the degraded DC characteristics such as the decreased Early voltage, the decreased collector-emitter breakdown voltage, and the highly increased base leakage current. Also, the cutoff frequency(f/sub T/) and the maximum oscillation frequency(f/sub max/) representing the AC characteristics are reduced to below 50%. These deteriorations are originated from the change of the locations of emitter-base and collector-base junctions, which is induced by the variation of the doping profile of boron in the SiGe base due to the high-temperature source-drain annealing. In the result, the junctions pushed out of SiGe region caused the parastic barrier formation and the current gain decrease on the SiGe HBT device.

Changes of discharge voltage of plate-type sodium sulfur batteries in the early charge/discharge cycles (평판형 나트륨 유황 전지의 초기 충방전시 방전전압 변화)

  • Kim, Seong-In;Kim, Heon-Tae;Choi, Hee-Lack;Lim, San-Su-Dae;Yang, Kee-Deok;Beum, Jin-Hyung;Kim, Chang-Sam
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.4
    • /
    • pp.164-168
    • /
    • 2014
  • The sodium-sulfur batteries which operate at $350^{\circ}C$ have been mainly used in the field of energy storage system. This batteries consist of liquid sodium anode, sulfur cathode and ${\beta}^{{\prime}{\prime}}$-alumina solid electrolyte. The conditioning process for stabilization of the batteries is essential since the cells show considerable fluctuation of discharge voltage at the beginning of discharge/charge cycles. It is found that one of the reasons of the fluctuation is the gradual change of contact area between molten sodium and solid electrolyte.

4H-SiC Schottky Barrier Diode Using Double-Field-Plate Technique (이중 필드플레이트 기술을 이용한 4H-SiC 쇼트키 장벽 다이오드)

  • Kim, Taewan;Sim, Seulgi;Cho, Dooyoung;Kim, Kwangsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.11-16
    • /
    • 2016
  • Silicon carbide (SiC) has received significant attention over the past decade because of its high-voltage, high-frequency and high-thermal reliability in devices compared to silicon. Especially, a SiC Schottky barrier diode (SBD) is most often used in low-voltage switching and low on-resistance power applications. However, electric field crowding at the contact edge of SBDs induces early breakdown and limits their performance. To overcome this problem, several edge termination techniques have been proposed. This paper proposes an improvement in the breakdown voltage using a double-field-plate structure in SiC SBDs, and we design, simulate, fabricate, and characterize the proposed structure. The measurement results of the proposed structure, demonstrate that the breakdown voltage can be improved by 38% while maintaining its forward characteristics without any change in the size of the anode contact junction region.

Effect of Nuclear Transfer Methods on In Vitro Development of Reconstituted Bovine Embryos I. Effect of Transfer Time of IVF Donor Nuclei and Electric Stimulation on Fusion and In Vitro Development (소에서 핵이식 방법이 재구축배의 체외발달에 미치는 영향 I. 체외수정 공핵배 핵의 이식시기와 전기자극에 따른 융합과 체외발달)

  • 정영채;김창근;송학웅;정영호;윤종택;이종완;김흥률;김광식
    • Korean Journal of Animal Reproduction
    • /
    • v.20 no.4
    • /
    • pp.459-465
    • /
    • 1997
  • The present study was undertaken to determine the effect of NT time on the rate of fusion a and suhseguent development In vitro and determine the optimal strength and duration of DC pulse for electrofusion of IVF donor embryo nuclei and IVM recipient oocytes. The recipient oocytes were enucleated 25 ~ 2Sh after IVM and further cultured for 18 ~ 20h prior to fusion for oocyte aging. IVF embryos as donor nuclei were C co cultured with BOEC for 16- to 32-cell stage development. The transfer time of donor bIas tomeres was 1~3h post-enucleation in early NT group and 1 ~ 18h post-enucleation in late NT group, respectively and fusion was performed 43~4Sh post-IVM. The fusion rate did not differ between the early NT and late NT group, but the rate of cleavage and 8- to 16-cell stage embryos in the late NT group was more higher than that in the early NT group. The fusion, cleavage and M+B development was high from O.7SkV /cm DC than from 1.0kV /cm DC voltage, resulting in 17.6% M+B from 0.75kV /cm DC voltage. No difference in fusion rate was among pulse durations, but 50 and 70 usec pulse duration showed slight high cleavage and M + B d development. The results indicate that the best NT time of IVF donor blastomeres into the enucleated oocytes was 42~44 post-IVM and the most suitable condition for electrofusion was a single 0.7SkV /cm DC voltage for SO~70$\mu$sec.

  • PDF

Investigation on Formation of Nanotube Titanium Oxide Film by Anodizing on Titanium in NaF Electrolytes (NaF 전해용액을 이용한 양극산화에 의한 타이타늄 표면의 나노튜브구조의 형성에 관한 연구)

  • Lim, Hyun-Pil;Park, Nam-Soon;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.183-190
    • /
    • 2009
  • The aim of this study is to find the condition of forming the favorable nanotubes by anodizing with NaF and $H_3PO_4$. Machined Ti discs were used for anode, and Platinum net was used for cathode. For electrolyte, $H_3PO_4$ and NaF solution were mixed. We controlled voltage, electrolyte concentration, anodizing time and formed nanotubes on Ti discs. After that, these were washed with distilled water for 24 hours and dried in the $40^{\circ}C$ oven for 24 hours. The surface structure of specimens were analyzed. The results were as follows : At 0.5 wt % NaF, according as increasing voltage and anodizing time, early state of nucleating pores were generated. At 1.0 wt % NaF, 20 V, 20 & 25 min, well-formed nanotubes were observed. At 1.0 wt % NaF, 30 V, structure of nanotube became bigger and interconnected. At 2.0 wt % NaF, no nanotubes were formed and it was unrelated with voltage and time. At 1.0 wt % NaF, 20 V, 20 - 25 min, well-ordered nanotubes were generated on Ti discs. For the formation of favorable nanotubes, it is considered that proper parameters such as electrolyte concentration, voltage, anodizing time are necessary according to the kind of electrolytes.

Thickness Design of Composite Pavement for Heavy-Duty Roads Considering Cumulative Fatigue Damage in Roller-Compacted Concrete Base (롤러전압콘크리트 기층의 누적피로손상을 고려한 중하중 도로의 복합포장 두께 설계)

  • Kim, Kyoung Su;Kim, Young Kyu;Chhay, Lyhour;Lee, Seung Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.537-548
    • /
    • 2022
  • It is important to design the pavement thickness considering heavy-duty traffic loads, which can cause excessive stress and strain in the pavement. Port-rear roads and industrial roads have many problems due to early stress in pavement because these have a higher ratio of heavy loads than general roads such as national roads and expressways. Internationally, composite pavement has been widely applied in pavement designs in heavy-duty areas. Composite pavement is established as an economic pavement type that can increase the design life by nearly double compared to that of existing pavement while also decreasing maintenance and user costs. This study suggests a thickness design method for composite pavement using roller-compacted concrete as a base material to ensure long-term serviceability in heavy-duty areas such as port-rear roads and industrial roads. A three-dimensional finite element analysis was conducted to investigate the mechanical behavior and the long-term pavement performance ultimately to suggest a thickness design method that considers changes in the material properties of the roller-compacted concrete (RCC) base layer. In addition, this study presents a user-friendly catalog design method for RCC-base composite pavement considering the concept of linear damage accumulation for each container trailer depending on the season.

A study of the voltage monitoring system with dial-up telephones (전화선을 이용한 전압 감시 시스템에 관한 연구)

  • Son, Myeong-Su;Nam, Kung-Do;Song, Byong-Kwon;Yoon, Kap-Koo;Jang, Me-Hea
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.107-111
    • /
    • 1996
  • In this paper, the voltage monitoring system is designed to monitor the outage and voltage fluctuation by using a dial-up telephone. The master station receives tire outage signal-such as interruption and voltage sag etc. - from the remote in on-line of real-time. The SCC(Serial Communication Controller) is adapted to monitor voltages multiple clients(about 256 clients) simultaneously. The voltage fluctuation in a normal range shall be transmitted to the master station, at early morning the clients use the telephone less frequently. The operating system shall be "window 95" and the database is programmed in Visual-basic for a easy analysis of voltage fluctuation.

  • PDF

A Study on the Application of Acoustic Emission Measurement for the In-process Detection of Milling Tools' Wear and Chipping (밀링 공구마멸과 치핑의 검출을 위한 음향방출 이용에 관한 연구)

  • Yoon, J.H.;Kang, M.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.1
    • /
    • pp.31-37
    • /
    • 1991
  • Acoustic emission(AE) signals detected during metal cutting were applied as the experimental test to sensing tool wear and chipping on the NC vertical milling machine. The in-process detection of cutting tool wear including chipping, cracking and fracture has been investigated by means of AE in spite of vibration or noise through intermittent metal cutting, then the following results were obtained 1) When the tool wear is increased suddenly, or the amplitude of AE signals changes largely, it indicates chipping or breaking of the insert tip. 2) It was confirmed that AE signal is highly sensitive to the cutting speed and tool wear. 3) At the early period of cutting, the wear were large and RMS value increased highly by the influence of minute chipping and cracking, etc. Therefore, the above situations should be considered for the time when the tool would be changed.

  • PDF

Acoustic Emission Monitoring Fine Wire Drawing Process (와이어 인발가공에 있어서 음향방출 발생 특성)

  • 이완규
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 1996
  • From a manufacturing standpoint it would be desirable to monitor the degradation of drawing die, that is essential for the maintenance of die quality, the evaluation of product integrity and the reducing scrap. Acoustic emission is powerful method in monitoring fine wire drawing process, especially in detecting the die fracture at early stage. Experiments also suggested that acoustic emission sigals contained valuable information regarding the stage of a drawing process such as the surface appearance of products and the condition of lubrication. These informations are AE monitoring techniques a possible tool in monitoring the drawing process operation. In order to approach this, this paper discusses the nature of acoustic emission signal presented which illustrate the effects of wire and die material, lubricants, and drawing speed on the generation and the mean voltage level of acoustic emission signal. From these experimental, results, we understanded controlling factors of acoustic emission generation.

  • PDF