• Title/Summary/Keyword: EXPOSURE

Search Result 15,168, Processing Time 0.043 seconds

Influences of the Plant Growth under Beta-Rays Irradiation at Low Dose (저 선량 베타선의 조사에 의한 식물의 생장에 미치는 영향)

  • Lee, Byung-Koo;Im, In-Chul;Kim, Jong-Eon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.143-148
    • /
    • 2010
  • This study is to analyze effects of the growth of Chunhyang Young Radish (CYR) and Altari Radish (AR) according to the exposure for 31 days at low dose ${\beta}$-rays. This test has one contrast sample and eleven test samples each as to AR and CYR. The seeds from contrast and test sample were planted in the culture soil after 8 seeds were chosen from each with identical condition. The accumulated dose of test samples has been measured at consistent time on a daily basis for 31 days. The growing process and germination have been measured twice at consistent time in each week. The number of leaves, length of first leave and weight have been acquired average value by measuring for 20 and 25 days, respectively after being planted. The result of test sample in case of 25 days shows that 5% increase in length and 36% increase in weight for AR each at accumulated dose 0.01 Gy compared to the contrast sample. And the length of CYR has increased by 13~17% and 1% at accumulated dose 0.01~0.08 Gy and 0.3 Gy compared to the contrast sample. For the weight at accumulated dose 0.05 Gy and 0.23 Gy has increased by 36% and 2% compared to contrast sample. As to the number of leaves, AR has increased by 0~50% at accumulated dose 0.01-0.32 Gy compared to contrast sample. It also shows that the CYR has increased to 0~67% at accumulated dose 0.01-0.62 Gy compared to contrast sample. As a result of this study, it indicates that both AR and CYR has generally increased in their length, weight, and the number of leaves at low level accumulated dose part 0.01~0.2 Gy. The size of cell, area of nucleus and density of cell for test sample has been observed quite similar to the ones from contrast sample through microscope. In conclusion, AR and CYR irradiated by ${\beta}$-rays have estimated that they are achieved a rapid growth at low level accumulated dose region corresponding to its radiation hormesis theory. Further studies need to confirm the correlation between the radiation hormesis and the growth of the plants.

Study on Optimized Dispensing of F-18 FDG Auto Dispenser (F-18 FDG 자동분주기의 분주 최적화에 관한 연구)

  • Ji, Bong-Geun;Lee, Sang-Hun;Kim, Jong-Eon;Kim, Won-Tae;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.377-384
    • /
    • 2016
  • This is a study on the optimized dispensing of the auto dispenser used for the purpose of reducing the exposure dose and accurate radiation dose of radioisotope with regard to the PET/CT practitioners. The research method was to find the optimized dispensing method through evaluating the results according to the syringe type, dispensing rate, and vial pressure and through the application of corrected values. As a result of this study, 9.38 mCi has been dispensed on average in the case of 5 ml syringe, and the reproducibility close to 10 mCi was shown at the dispense of 9.55 mCi in the case of 3 ml syringe. In the evaluation according to the dispensing rate, the quantity of radioisotope close to 10 mCi was dispensed at the rate of 5 mm/min when the measurement was carried out by increasing the rate by 5 mm/min units in the order of 5, 10, 15 and 20 mm/min. In the evaluation result according to the vial pressure before/after the use of Needle filter, it was measured to be 9.53 mCi before use and 9.84 mCi after use confirming that the dispensing after using Needle filter showed the optimal value. In addition, in the evaluation of radioactivity before/after the application of corrected values according to the increase in dispense frequency, it was measured 9.53 mCi before correction and 10.07 mCi after correction confirming that the value with correction applied was closer to the quantitative value. Thus, a good optimized method was confirmed to use a 3 ml syringe with dispensing rate of 5 mm/min, to use a Needle filter at dispensing, and to set the corrected value of [$y=0.097{\times}x$] according to the dispensing frequency of equipment.

Clinical Application of 3-D Conformal Radiotherapy for Carcinoma of the Ethmoid Sinus : I. Comparative Analysis Between Conventional 2-D and 3-D Conformal Plans (사골동 종양의 3-차원 입체조형치료 : I. 2차원 치료계획과 3차원 치료계획의 비교분석)

  • Lee Sangwook;Kim Gwi Eon;Keum Ki Chang;Park Hee Chul;Cho Jae Ho;Han Soung Uk;Lee Kang Kyu;Suh Chang Ok;Hong Won Pyo;Park In Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.287-296
    • /
    • 1997
  • Purpose : This is study of whether 3-D conformal radiotherapy for carcino-mas of the ethmoid sinus were better than those treated with conventional 2-D plan, Materials and Methods : The 3-D conformal treatment Plans were compared with conventional 2-D plans in 4 patients with malignancy of the ethmoid sinus. Isodose distribution, dose statistics, and dose volume histogram of the planning target volume were used to evaluate differences between 2-D and 3-D plans. In addition. the risk of radiation exposure of surrounding normal critical organs are evaluated by means of point dose calculation and dose volume histogram. Results : 3-D conformal treatment plans for each patient that the better tumor coverages by the planning target volume with improved dose homo-geneity, compared to 2-D conventional treatment Plans in the same Patient. On the other hand, the radiation dose distributions to the surrounding nor-mal tissue organs, such as the orbit and optic nerves are not significantly reduced with our technique, but a substantial sparing in the brain stem and optic chiasm for each patient. Conclusion : Our findings represented the potential advantage of 3-D treatment planning for dose homogeniety as well as sparing of the normal tissue surrounding the tumor. However, further investigational studies are required to define the clinical benefit.

  • PDF

The Cell Cycle Dependence and Radiation-induced Apoptosis in SCK Mammary Adenocarcinoma Cell Line (SCK선암 세포주에서 방사선에 의한 Apoptosis와 세포 주기)

  • Lee Hyung Sik;Park Hong Kyu;Hur Won Joo;Seo Su Yeong;Lee Sang Hwa;Jung Min Ho;Park Heon Joo;Song Chang Won
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.91-98
    • /
    • 1998
  • Purpose : The relationship between environmental PH on the radiation induced-apoptosis in SCK mammary adenocarcinoma cells and cell cycle dependence was investigated. Material and Methods : Mammary adenocarcinoma cells of A/J mice(SCK cells) in exponential growth phase were irradiated with a $l37^Cs$ irradiator at room temperature. The cells were irradiated 1 hour after the media was replaced with fresh media at a different pHs. After incubation at $37^{\circ}C$ for 0-48 h, the extent of apoptosis was determined using agarose gel electrophoresis and flow cytometry. The progression of cells through the cell cycle after irradiation in different pHs was also determined with flow cytometry. Bssults : The induction of apoptosis by irradiation in pH 6.6 medium was markedly less than that in pH 7.5 medium. When the cells were irradiated and maintained in pH 7.5 medium, the percentage of cells in $G_2/M$ phase rapidly increased to about $70\%$ at 12 h after an exposure to 120y and returned to control level by 36 h. The percentage of cells in G1 phase decreased as the percentage of cells in $G_2/M$ increased. On the other hand, in pH 6.6 medium the percentage of cells in G2/M phases gradually increased to about $45\%$ at 24 h after 12Gy irradiation and then slowly recessed and consequently, as much as $30-35\%$ of the cells were still in the Ga/M phase 48 h after irradiation. The percentage of cells in G1 phase then increased as the Ga/M arrest began to recede. The radiation-induced Ga/M arrest in PH 0.0 medium lasted markedly longer than that in pH 7.5 medium. Conclusion : Radiation-induced apoptosis in SCK tumor cells are reversely suppressed in an acidic environment. Radiation-induced Ga/M arrest is prolonged in an acidic environment indicating that the suppression of radiation-induced apoptosis and prolongation of radiation-induced Ga/M arrest in an acidic environment are related.

  • PDF

The Average Glandular Dose in Mammography and Quality Control of the Equipment Status (유방촬영검사에서 평균유선선량과 장치의 품질관리 실태)

  • Jung, Hong-Ryang;Hwang, Su-Lyun;Ha, Bon-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.111-120
    • /
    • 2011
  • A purpose of study is to develop optimization and radiation dose exposure reference level by measuring actual radiation dose in condition of quality control of mammography equipment for 39 clinics. The result were as follows. First, we measured T-test separating radiology from general clinic. According to the test, mAs was measured at average 78.58 mAs; radiology at 80.16 mAs and general clinic at 77.22 mAs. And, kerma rate was measured at average 7.71 mGy/mR; radiology at 8.94 mGy/mR and general clinic at 6.66 mGy/mR. HVL was measured at average 0.42 mmAl; radiology at 0.40 mmAl and general clinic at 0.43 mmAl. Average glandular dose was measured at average 1.14 mGy; radiology at 1.09 mGy and general clinic at 1.19 mGy. Second, we measured value of mAs, HVL, processing method and so on dividing two groups. And, we compared and analyzed average value measured using T-test. As a result, there was significance level in SID(P<0.05). There was significance level in mAs(P<0.05). Because processor was measured at 1.00 mGy and CR at 1.17 mGy according to the processing method of radiology. Third, according to the correlation analysis, radiology had significance level between average glandular dose and mAs and general clinic had significance level between average glandular dose and SID(P<0.05). Forth, as a result of regression analysis, mAs affected 22.7%t of average glandular dose and SID affected 21.7% of average glandular dose, which had significance level(P<0.05). And, mAs affected 29.0% of average glandular dose in radiology and SID affected 29.1% of average glandular dose in general clinic, which was most influential.

Effect of Submergence and Air Exposure of the Shoot on Growth, Nutrient Uptake and Photosynthesis in Monochoria vaginalis Presl. (물달개비 경엽(莖葉)의 침수여부(沈水與否)에 따른 생장(生長), 양분흡수(養分吸收) 및 광합성(光合成) 비교(比較))

  • Soh, C.H.;Yang, K.S.;Kwon, Y.W.
    • Korean Journal of Weed Science
    • /
    • v.16 no.1
    • /
    • pp.14-20
    • /
    • 1996
  • Growth, nutrient uptake and photosynthesis as affected by submersion of shoot in pickerel weed (Monochoria vaginalis Presl.) were determined. The shoots of pickerel weeds in hydroponic culture were subjected to the submerged or emerged condition at 3- or 5-leaf stage for 8 or 10 days. Under submerged condition, growth in plant height was enhanced, but leaf number, leaf area, fresh and dry weight were reduced compared to those under the emerged condition. Similar responses in growth to submergence were obtained with the pickerel weeds rooted in the soil. Under submergence, chlorophyll content increased during the first 2 days, but thereafter remarkably decreased at 3-leaf stage and after the first 4 days at 5-leaf stage. Compared to the emerged condition, uptakes of $NH_4\;^+$-N, $NO_3\;^-$-N, $P_2O_5$ and $K^+$ were reduced, but uptakes of $Ca^{++}$ and $Mg^{++}$ increased under the submerged condition. Photosynthetic rate of shoot under water, measured by $CO_2$electrode, showed the maximum by 210 ${\mu}$moles $HCO_3\;^-$/g F.W. at the 8th day after submergence(DAS) at 3-leaf stage and 320 ${\mu}$moles $HCO_3\;^-$/g F. W. at 6 DAS at 5-leaf stage. These results indicate that pickerel weeds grow much better when the shoot is air-exposed and are less tolerable to submergence at 3 leaf-stage than at 5-leaf stage.

  • PDF

Acute Respiratory Infections in the Neonatal Intensive Care Unit: Isolation of Viruses and the Characteristics of Respiratory Syncytial Virus Infection (신생아집중치료실에서의 급성 호흡기 감염-바이러스의 검출 및 respiratory syncytial virus 감염의 임상적 특징)

  • Park, Sun-Hee;Cho, Hye-Jung;Shim, So-Yeon;Son, Dong-Woo;Eun, Byung-Wook;Sun, Yong-Han;Tchah, Hann;Jeon, In-Sang
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.182-189
    • /
    • 2009
  • Purpose: Recently, it is easy to find the causal virus of acute respiratory infections using multiplex RT-PCR. The aim of this study is to show the distribution of respiratory viruses and to define the characteristics of respiratory syncytial virus (RSV) infections compared to other respiratory viral infections. Methods: This was a prospective observational study conducted in the NICU. The infants with acute respiratory infections were performed multiplex RT-PCR using nasal swabs. The demographics, initial symptoms, course of illness, and laboratory and imaging findings were recorded. The infants were divided into RSV and No RSV groups. Results: Twenty-three infants (50%) were in the RSV group. Rhinovirus was the second most common virus. Coinfections with two viruses accounted for 6.5% of respiratory infections. The number of preterm infants, exposure to cigarette smoke and having siblings were not different between the two groups. Infections in the postnatal care center were more common in the RSV group than the No RSV group (60.9% vs. 21.7%, P=.007). Dyspnea (34.8% vs. 8.7%, P=.032) and pneumonia (73.9% vs. 43.5%, P=.036) were more common in the RSV group. The RSV group frequently needed oxygen (52.5% vs. 13.0%, P=.005) and received nothing by mouth (43.5% vs. 13.0%, P=.022). The incidence of right upper consolidation was higher in RSV group (56.5% vs. 8.7%, P=.001). Conclusion: This study showed that other viruses than RSV can induce respiratory infections in neonates and young infants born prematurely. RSV infections have a more severe course of illness than other respiratory viruses. We have to be careful of prevention even for healthy neonates especially in crowed situations, such as the postnatal care center.

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF

Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure (유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과)

  • Ryu, Young Hyo;Uhm, Han Sup;Park, Gyung Soon;Choi, Eun Ha
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.55-65
    • /
    • 2013
  • Sterilization of Neurospora crassa has been investigated in this research by using a surface air plasma with dielectric barrier discharged (DBD) structure under atmospheric pressure. The sinusoidal alternating current has been used in this experiment with discharge voltage of 1.4~2.3 kV. The phase difference between the voltage and current signals are found to be almost 80 degree due to the capacitive property of dielectric barrier. Temperature on the biomaterials has been minimized by radiating the heat with the air cooling system. It is noted that the substrate temperature remains under 37 degree for plasma exposure time of 10 minutes with operation of cooler system. It is found that the ozone, $O_3$, has been measured to be about 25~30 ppm within 1 cm region and to be about 5 ppm at the 150 cm downstream region away from the suface plasma. It is also noted that the nitric oxide, NO, and nitric dioxide, $NO_2$, are not nearly detected. Germination rate and mitochodrial activity of Neurospora crassa immersed in the deionized water have been found to be drastically decreased as the plasma treatment time and its electrical power are increased in this experiment. Here, the mitochondrial activity has been analyzed by MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) assay. However, sterilization of Neurospora crassa immersed in the Vogel's minimal media has been found to be low by plasma treatment, which is caused by surrounding background solution. This research shows the sterilization possibility of Neurospora crassa by using the noncontated surface DBD plasma, which is different from the plasma jet. This is mainly attibuted to the reactive species generated by the surface plasma, since they play a major role for inhibition of micobes such as Neurospora crassa.

The PRISM-based Rainfall Mapping at an Enhanced Grid Cell Resolution in Complex Terrain (복잡지형 고해상도 격자망에서의 PRISM 기반 강수추정법)

  • Chung, U-Ran;Yun, Kyung-Dahm;Cho, Kyung-Sook;Yi, Jae-Hyun;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.2
    • /
    • pp.72-78
    • /
    • 2009
  • The demand for rainfall data in gridded digital formats has increased in recent years due to the close linkage between hydrological models and decision support systems using the geographic information system. One of the most widely used tools for digital rainfall mapping is the PRISM (parameter-elevation regressions on independent slopes model) which uses point data (rain gauge stations), a digital elevation model (DEM), and other spatial datasets to generate repeatable estimates of monthly and annual precipitation. In the PRISM, rain gauge stations are assigned with weights that account for other climatically important factors besides elevation, and aspects and the topographic exposure are simulated by dividing the terrain into topographic facets. The size of facet or grid cell resolution is determined by the density of rain gauge stations and a $5{\times}5km$ grid cell is considered as the lowest limit under the situation in Korea. The PRISM algorithms using a 270m DEM for South Korea were implemented in a script language environment (Python) and relevant weights for each 270m grid cell were derived from the monthly data from 432 official rain gauge stations. Weighted monthly precipitation data from at least 5 nearby stations for each grid cell were regressed to the elevation and the selected linear regression equations with the 270m DEM were used to generate a digital precipitation map of South Korea at 270m resolution. Among 1.25 million grid cells, precipitation estimates at 166 cells, where the measurements were made by the Korea Water Corporation rain gauge network, were extracted and the monthly estimation errors were evaluated. An average of 10% reduction in the root mean square error (RMSE) was found for any months with more than 100mm monthly precipitation compared to the RMSE associated with the original 5km PRISM estimates. This modified PRISM may be used for rainfall mapping in rainy season (May to September) at much higher spatial resolution than the original PRISM without losing the data accuracy.