Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy

고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정

  • Yoon, Jae Sik (Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital) ;
  • Lee, Jae Gon (Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital) ;
  • Lee, Ki Hyun (Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital) ;
  • Lim, Kwang Seok (Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital) ;
  • Choi, Hak Ki (Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital) ;
  • Lee, Sang Mi (Department of Nuclear Medicine, Soonchunhyang University Cheonan Hospital)
  • 윤재식 (순천향대학교 천안병원 핵의학과) ;
  • 이재곤 (순천향대학교 천안병원 핵의학과) ;
  • 이기현 (순천향대학교 천안병원 핵의학과) ;
  • 임광석 (순천향대학교 천안병원 핵의학과) ;
  • 최학기 (순천향대학교 천안병원 핵의학과) ;
  • 이상미 (순천향대학교 천안병원 핵의학과)
  • Received : 2014.03.28
  • Accepted : 2014.04.21
  • Published : 2014.05.23

Abstract

Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

갑상선 분화암 환자의 방사선 치료에서 I-131의 유효반감기는 환자에게 투여하는 양의 계산뿐만 아니라 환자의 격리 입원기간의 결정, 환자로부터 가족들이 받게 되는 선량을 계산하는데 유용한 값이다. 하지만 이 값은 물리적반감기와는 달리 실측을 해야만 얻을 수 있어 입원 격리중인 환자에게 계측하기가 기술적으로 어려운 문제가 있다. Dual time I-131 whole body scan의 초기촬영과 지연촬영 사이의 체내잔류방사능량을 이용하여 전신과 갑상선에 유효반감기를 추정해 보았다. 또한 혈중 크레아티닌 농도, GFR, 투여량이 유효반감기와 상관관계가 있는지 알아보았다. 유효반감기 측정을 위해 전신에 체내잔류방사능량과 갑상선의 잔류방사능량을 측정하기 위해 환자의 전신을 흥미영역으로 설정한 후 배후방사능을 보정하여 전신의 체내잔류방사능량을 획득하였고, 갑상선 부위에 ROI를 설정한 후 배후 방사능을 보정하여 갑상선의 잔류방사능량을 획득하였다. 초기영상과 지연영상의 측정값 사이의 비율을 계산하여 전신과 갑상선의 유효반감기를 구하였다. 또한 유효반감기와 GFR, 혈중크레아티닌 농도, I-131 투여량과의 상관관계를 분석하였다. 전신의 체내잔류방사능량을 측정한 값의 유효반감기는 $17.06{\pm}5.50$시간으로 나타났고 갑상선의 잔류방사능량을 측정한 값의 유효반감기는 $17.22{\pm}5.41$시간으로 나타났으며 두 유효반감기는 유의한 차이를 보이지 않았다(P=0.887). GFR 값이 올라갈수록 전신의 유효반감기(r=-0.407, P=0.003)와 갑상선 유효반감기(r=-0.473, P=0.001) 모두 유의하게 감소하였으며 혈중크레아티닌 농도가 올라갈수록 전신의 유효반감기(r=0.309, P=0.029)와 갑상선 유효반감기(r=0.371, P=0.008) 모두 유의하게 증가하였다. 투여량은 두유효반감기와 상관관계를 보이지 않았다. 본 연구를 통해 고용량 방사성요오드 치료환자 입원기간의 최적화 연구와 기존 유효반감기를 구하기 위해 종사자의 피폭 및 복잡성을 보완하여 간편하게 측정을 할 수 있을 것이라 생각한다. 또한 분석된 갑상선의 유효반감기를 적용한 MIRD schema의 내부피폭선량 평가 연구에도 활용할 수 있을 것으로 사료된다.

Keywords