• Title/Summary/Keyword: ESI-MS

Search Result 438, Processing Time 0.026 seconds

Simultaneous determination of low molecular weight amines and quaternary ammonium ions by IC/ESI-MS

  • Jung, Joo-Young;Park, Han-Seok;Kim, Kang-Jin
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.255-260
    • /
    • 2007
  • A new method for the simultaneous determination of low molecular weight amines and quaternary ammonium ions based on the separation by IC with a suppressor and the detection by MS with ESI has been developed. The method has been applied to the analysis of a mixture containing tetramethylammonium ion, tetraethylammonium ion, tetrapropylammonium ion, triethanolamine, trimethylamine and triethylamine. The constituents were separated by isocratic elution using an IonPac CS17 column, a cation-exchange column, and detected by conductivity and mass spectrometry. The newly developed method for the six components demonstrated that the repeatability in terms of relative standard deviation for three measurements was in the range of 0.1-0.5 %. The detection limits were between 0.2 and $0.9{\mu}g/mL$ by the IC/ESI-MS.

Quantitative Analysis and Qualification of Amitrole Using LC/ESI-MS (LC/ESI-MS를 이용한 아미트롤의 정성확인 및 정량분석)

  • Park, Chan-Koo;Eo, Soo-Mi;Kim, Min-Young;Sohn, Jong-Ryeul;Mo, Sae-Young
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.117-129
    • /
    • 2004
  • Amitrole in environment, difficult to be analyzed by GC or GC/MS due to high polarity and low volatility, was analyzed by LC/ESI/MS in the study. Maximum peak intensity of amitrole in LC/MS/ESI mass spectrum is m/z 85 of protonated molecular ion $(M+H)^+$ with 30V of cone voltage at SIR mode. It was confirmed that ratios between main ion of amitrole, 85 of protonated molecular ion, and m/z 58 fragmented ion of amitrole, had increased corresponding with the increment of cone voltage from 20V to 70V. The isotope molecular weight of amitrole was $86([M+H])^+$ at LC/MS analysis and the mass spectrum ratio between 85 mass and 86 mass was not different by the change of concentration but similar to theoretical ratio(less than 10% standard deviation).The linearity of standard calibration curve under same condition with sample treatment method had $y=1.09354e^6X+26947.2$ and $r^2=0.99$. Recovery rates in water and soil samples were 77.64~83.44% and 71.11~79.44%, respectively. Reliability of the analysis was performed with 5 repeated measurements at each level of standard concentration and the result showed that relative standard deviation was less than 10%; therefore, the extraction and analysis method in the study suggested that it would be reliable to measure amitrole in water and soil media.

Estimation of Impurities from Commercially Available Glycyrrhizin Standards by the HPLC/ESI-MS (HPLC/ESI-MS에 의한 글리시리진 표준품의 불순물 추정)

  • Myung, Seung-Woon;Min, Hye-Ki;Kim, Myungsoo;Kim, Young Lim;Park, Seong-Soo;Cho, Jung Hee;Lee, Jong-Chul;Cho, Hyun-Woo;Kim, Taek-Jae
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.504-510
    • /
    • 2000
  • The impurity profiles from the raw materials of glycyrrhizin were performed by the high performance liquid chromatography (HPLC)/electrospray ionization (ESI)- mass spectrometry (MS). For the HPLC experiment, a $C_{18}$($3.9{\times}300mm$, $10{\mu}m$) column was used and the mobile phase was acetic acid/$H_2O$ (1:10):acetonitrile=3:2 with a flow rate of 0.8 ml/min. The effluent was splitted into the ratio of 50:1 and went into the ESI-MS. Three to six impurities were found and informed of the identification of the structure of the impurities by ESI-MS. And the structures of impurities were suggested to a hydroxy-glycyrrhizin which is added with hydroxy group (-OH) in the glycyrrhetic acid moiety and a reduced-glycyrrhizin which the position of 12 of the glycyrrhetic acid moiety is reduced. The purities of the standard materials were about 90%.

  • PDF

Quantitative Evaluation of Radix Astragali through the Simultaneous Determination of Bioactive Isoflavonoids and Saponins by HPLC/UV and LC-ESI-MS/MS

  • Kim, Jin-Hee;Park, So-Young;Lim, Hyun-Kyun;Park, Ah-Yeon;Kim, Ju-Sun;Kang, Sam-Sik;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.7
    • /
    • pp.1187-1194
    • /
    • 2007
  • The three major active isoflavonoids (calycosin-7-O-β -glucoside, isomucronulatol 7-O-β-glucoside, formononetin) and two main saponins (astragaloside I, astragaloside IV) in an extract of Radix Astragali were determined using rapid, sensitive, reliable HPLC/UV and LC-ESI-MS/MS methods. The separation conditions employed for HPLC/UV were optimized using a phenyl-hexyl column (4.6 × 150 mm, 5 μm) with the gradient elution of acetonitrile and water as the mobile phase at a flow rate of 1.0 mL/min and a detection wavelength of 230 nm. The specificity of the peaks was determined using a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source that was operated in multiple reaction monitoring (MRM) in the positive mode. These methods were fully validated with respect to the linearity, accuracy, precision, recovery and robustness. The HPLC/UV method was applied successfully to the quantification of three major isoflavonoids in the extract of Radix Astragali. The results indicate that the established HPLC/UV and LC-ESI-MS/MS methods are suitable for the quantitative analysis and quality control of multi-components in Radix Astragali.

Determination of acidic pharmaceuticals in aquatic environmental samples by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 수질 환경 시료 중 산성의약물질 분석방법 비교)

  • Sim, Young-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2008
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in aquatic environmental samples. Therefore, it required rapidly and certainly analytical method for pharmaceuticals which are existed in environment. In this study, Liquid chromatography/tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) was used to measure the concentrations of 7 pharmaceuticals (quinoxaline-2-carboxylic acid, acetylsalicylic acid, diclofenac-Na, naproxen, ibuprofen, mefenamic acid, talniflumate) from environmental water or aquatic samples simultaneously. Effective sample clean-up by solid-phase extraction (SPE) prior to LC-MS/MS analysis is necessary. For further purification, Mixed Cation eXchange (MCX) and Hydrophilic-Lipophilic Balance (HLB) solid-phase extraction (SPE) cartridges were used to eliminate the remaining interferences. LODs (Limits of Detection) and MDLs (Method Detection Limits) for the spiked sample in fresh water were in the range of 0.05~1.50 pg/mL and 0.17~4.90 pg/mL, respectively. The absolute recovery in the concentration of 1.0 ng/mL were between 81.9 and 116.3%. The acidic pharmaceuticals were detected in concentrations of 0.018~16.925 ng/mL in aquatic environmental samples.

Quantitative Determination of the Bioactive Marker Components in Gyeji-tang Using LC-ESI-MS/MS (LC-ESI-MS/MS를 이용한 계지탕 중 주요 성분 분석)

  • Seo, Chang-Seob;Ha, Hyekyung
    • Korean Journal of Pharmacognosy
    • /
    • v.49 no.1
    • /
    • pp.76-83
    • /
    • 2018
  • A traditional herbal formula, Gyeji-tang has been used to treat the early colds, headache, chills, and fever in Asian countries. In this study, we were performed simultaneous determination of the 14 bioactive marker compounds, gallic acid, spinosin, paeoniflorin, albiflorin, liquiritin apioside, liquiritin, 6'''-feruloylspinosin, liquilitigenin, coumarin, cinnmamic acid, benzoylpaeoniflorin, cinnamaldehyde, glycyrrhizin, and 6-gingerol in Gyeji-tang using an ultra-performance liquid chromatography-electrospray ionization-mass spectrometry (UPLC-ESI-MS/MS). Analytical column was used a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$) and maintained at $45^{\circ}C$ with a flow rate of 0.3 mL/min. The mobile phase consists of 0.1% (v/v) formic acid in water and acetonitrile with gradient elution. The MS analysis was conducted using multiple reaction monitoring in the positive and negative modes by a Waters ACQUITY TQD LC-MS/MS system. The calibration curves of 14 bioactive marker compounds showed linearity with correlation coefficients ${\geq}0.9798$. The limits of detection and quantification values were in the range of 0.11-6.66 ng/mL and 0.34-19.99 ng/mL, respectively. As a result of the analysis using the established LC-MS/MS method, the amounts of tested 14 compounds in the lyophilized Gyeji-tang sample were detected up to $85.7{\mu}g/g$. These results may be useful for quality assessment of a traditional herbal formulas.

Quantitative Analysis of trans-Resveratrol in Red Wines by Solid Phase Extraction and LC/MS (고체상 추출법과 LC/MS를 이용한 적포도주 중의 trans-Resveratrol 분석)

  • Park, Gyo-Beom;Moon, Hyoung-Sil;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.125-133
    • /
    • 2003
  • In order to determine the contents of trans-resveratrol in red wine, which was mainly consumed in Korea, both LC/MS-ESI and LC/MS-APCI methods were used after solid-phase (Sep-Pak $C_{18}$-cartridges) extraction. The contents of trans-resveratrol obtained by LC/MS-ESI were detected in the range of $0.06-4.31{\mu}g/mL$. The recoveries were ranged from 88.4 to 97.9%. The values of relative standard deviation were ranged from 0.6 to 4.6% and the detection limit was $0.001{\mu}g/mL$. The contents of trans-resveratrol obtained by LC/MS-APCI were detected in the range of $0.09-4.02{\mu}g/mL$ and the detection limit was $0.005{\mu}g/mL$.

Simultaneous Determination of Ultra-Trace Pesticides and Synthetic Materials in Surface Water by LC-ESI-MS/MS (하천수에서 LC-ESI-MS/MS에 의한 극미량 농약류 및 합성원료의 동시분석법)

  • Hong, Seon-Haw;Lee, Jun-Bae;Lee, Soo-Hyung;Cho, Young-Hwan;Shin, Ho-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining seven pesticides (2,4-dichlorophenoxyacetic acid, methomyl, aldicarb, 2-methyl- 4-chlorophenoxy- acetic acid, molinate, carbaryl and carbofuran) and two synthetic materials (quinoline and bisphenol-A) in surface water. The analytes were extracted using solid-phase extraction (SPE). The eluate was concentrated by nitrogen gas. 100 microliters of 30% (v/v) methanol aqueous solution were used to dissolve the residue and an aliquot of the reconstituted solution was directly injected into LC-ESI-MS/MS after the filtration using 0.2 μm polytetrafluoroethylene (PTFE) syringe filter. Under the established condition, the calibration curves of the analytes were linear with correlation coefficients of above 0.997. The quantification limit was 0.002~0.011 μg/L and the relative standard deviations were less than 16.4%. In addition, accuracy was in the range of 84~107% and the recoveries were values between 56.2 and 98.6%. In this study, the developed method was applied to the analysis of real surface water samples.

Analysis of Sildenafil and its Analogues by LC/MS/MS (LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석)

  • Myung, Seung-Woon;Park, So-Hee;Cho, Hyun-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.488-498
    • /
    • 2003
  • By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.

Rapid Identification of Radical Scavenging Compounds in Blueberry Extract by HPLC Coupled to an On-line ABTS Based Assay and HPLC-ESI/MS

  • Kim, Chul-Young;Lee, Hee-Ju;Lee, Eun-Ha;Jung, Sang-Hoon;Lee, Dong-Un;Kang, Suk-Woo;Hong, Sae-Jin;Um, Byung-Hun
    • Food Science and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.846-849
    • /
    • 2008
  • This study employed high performance liquid chromatography (HPLC) coupled to an on-line $ABTS^+$ radical scavenging detection (RSD) system along with HPLC-electro spin impact/mass spectrometry (ESI/MS), to rapidly determine and identify antioxidant compounds occurring in blueberry extract. The extract was separated by HPLC, and then the radical scavenging activities of the separated compounds were evaluated by the on-line coupled $ABTS^+$-RSD system. The negative peaks of the $ABTS^+$-RSD system, which indicates the presence of antioxidant activity, were monitored by measuring the decrease in absorbance at 734 nm. The active components in the blueberry extract were identified by HPLC-ESI/MS using their MS spectra and retention times. According to the data acquired from the on-line HPLC-$ABTS^+$-based assay and HPLC-ESI/MS systems, the antioxidant compounds detected in the blueberry extract were identified as chlorogenic acid and 11 anthocyanins.