• Title/Summary/Keyword: ESD

Search Result 471, Processing Time 0.021 seconds

ATC: An Image-based Atmospheric Correction Software in MATLAB and SML

  • Choi, Jae-Won;Won, Joong-Sun;Lee, Sa-Ro
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.5
    • /
    • pp.417-425
    • /
    • 2008
  • An image-based atmospheric correction software ATC is implemented using MATLAB and SML (Spatial Modeler Language in ERDAS IMAGINE), and it was tested using Landsat TM/ETM+ data. This ATC has two main functional modules, which are composed of a semiautomatic type and an automatic type. The semi-automatic functional module includes the Julian day (JD), Earth-Sun distance (ESD), solar zenith angle (SZA) and path radiance (PR), which are programmed as individual small functions. For the automatic functional module, these parameters are computed by using the header file of Landsat TM/ETM+. Three atmospheric correction algorithms are included: The apparent reflectance model (AR), one-percent dark object subtraction technique (DOS), and cosine approximation model (COST). The ACT is efficient as well as easy to use in a system with MATLAB and SML.

Endoscopic Management of Gastric Subepithelial Tumor (위상피하종양의 내시경적 진단 및 치료)

  • Hyunchul Lim
    • Journal of Digestive Cancer Research
    • /
    • v.10 no.1
    • /
    • pp.16-21
    • /
    • 2022
  • Diagnosis of gastric subepithelial tumors (SETs) is sometimes difficult with conventional endoscopy or tissue sampling with standard biopsy, so non-invasive imaging modalities such as endoscopic ultrasound (EUS) and computed tomography are used to evaluate the characteristics of SETs features (size, location, originating layer, echogenicity, shape). However imaging modalities alone is not able to distinguish among all types of SETs, so histology is the gold standard for obtaining the final diagnosis. For tissue sampling, mucosal cutting biopsy and mucosal incision-assisted biopsy and EUS-guided fine-needle aspiration or biopsy (EUS-FNA or EUS-FNB) is commonly recommended. Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) are used for resection of SETs involving the mucosal and superficial submucosal layers, could not treat adequately and safely the SETs involving the deep mucosa and muscularis propria. Submucosal tunneling endoscopic resection (STER) and endoscopic full-thickness resection (EFTR) is used as a therapeutic option for the treatment of SETs with the development of reliable endoscopic closure techniques and tools.

A Comparative Study on the Lens Dose According to the Change of Shielding Material Used in Brain Computed Tomography (Brain CT에서 차폐 재료 변화에 따른 수정체 선량 비교 연구)

  • Hwang, Incheol;Shin, Woonjae;Gang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • The cases of radiographic inspection for medical diagnosis in Korea have been continuously increasing year after year, which pays particularly more attention to CT which occupies over the half of medical radiation exposure. To find an effective alternative for reducing radiation exposure, the researchers conducted comparative experiments using some shields made of bismuth, aluminum 6mm, and silicone 22mm. These shielding materials have been used to reduce the entrance surface dose (ESD) on lenses, maintaining the CT number, noise, and uniformity in brain CT scanning which forms the largest part in CT scanning these days. These experiments showed that the doses in the spiral scan parallel to IOML and the conventional scan in Bismuth were 26.41% and 17.52%, respectively; in Aluminum 18.24% and 9.39%; in Silicone 19.47% and 14.39% lower than compared with those in the cases without any shields. In the items of the CT number, noise, and uniformity, the bismuth shield satisfied exceedingly the standards of the phantom image test while aluminum and silicone were within. To keep the graphic quality and get good shielding effect, we recommend the silicone shield which can be manufactured and purchased with ease.

Analysis on Foaming Properties of the PANI added MWNT/PU Films (PANI 첨가 MWNT/PU 필름의 발포특성)

  • Ma, Hye-Young;Choi, La-Hee;Park, Mi-Ra;Kim, Seung-Jin
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.63-63
    • /
    • 2012
  • 전자제품 패키지에 요구되는 쿠션성과 정전방전 기능을 갖는 폴리우레탄 발포 필름의 제조기술을 확립하게 되면 IT산업용에 적용 가능한 필름제품이 개발되어 ESD(정전방전, Electrostatic Dissipation) 성능을 발휘하게 됨으로서 정전기 쇼크에 의한 각종 전자제품의 오작동이나 파손 방지가 가능하게 되어 포장재, 자동차 전자제품의 하우징 등으로 사용될 수 있게 된다. 전도성 고분자인 Polyaniline (PANI)은 다른 여러 고분자와 비교하여 볼 때 다른 유형의 전도성 고분자보다 합성하기가 쉽고 높은 전기전도도를 보임은 물론 열적 및 대기 안정성이 우수하며 가격이 저렴한 장점을 가지고 있다. 본연구는 CNT 나노기술을 응용한 IT산업용 적층간지용 ESD PU발포필름의 제조 가공기술 및 상품화 개발을 수행하고자 방수, 투습방수성을 가지는 유연재료인 폴리우레탄(PU)의 1액형 PU와 DMF에 PANI의 함량을 5, 10, 15, 20, 25, 30wt%로 변화시켜 제조한 PANI/DMF 분산용액과 IPA/MWNT 3wt% 분산용액의 혼용비에 변화를 주어 $120^{\circ}C$에서 2분 건조시켜 그라운드 필름을 제조하였다. 그리고 2액형 PU와 IPA/MWNT 3wt% 분산용액과 발포제를 사용하여 발포온도 $150^{\circ}C$에서 5분간 건조시켜 발포필름을 제조하였으며 이들의 전기적 특성과 역학적 특성을 조사하였다. 제조된 필름의 전기전도성은 전기저항측정기 KEITHLEY 8009를 사용하여 부피저항과, 표면저항을 각각 측정하여 확인하였으며, 필름의 마찰 대전압은 E.S.T-7 마찰 대전압 시험기를 이용하여 표면 마찰 대전압을 측정하여 확인하고, 필름의 물리적 특성은 인장시험기를 이용하여 breaking stress, breaking strain을 측정하였다. 필름단면의 CNT 발포특성은 주사전자현미경(SEM)을 사용하여 측정하여 발포특성과 물성과의 연관성을 확인하였다. 그 결과 필름의 전기적 특성은 PANI가 30% 함량일 때 전반적으로 낮은 저항값이 측정되었으며, 마찰대전압을 측정한 결과 대부분의 시료가 0에 가까운 낮은 값을 가졌다. 필름의 물리적 인장특성은 PANI가 10wt%의 함량일 때 가장 높은 절단강도를 가졌으며 분산용액의 혼용비에 따른 경향성은 나타나지 않았다. 필름의 단면형상을 확인하여 발포특성을 분석한 결과 PANI의 함량에 따라 발포 cell의 크기는 뚜렷한 경향성을 보이지 않았으나 30wt%의 PANI/DMF 분산용액 20part(gr)와 3wt% IPA/MWNT 분산용액 40part(gr)로 제조한 시료의 cell이 가장 균일하고 고르게 발포되었으며, 3.90E+06ohm으로 가장 낮은 표면저항 값으로 측정되어 가장 좋은 전기전도성을 가짐을 확인하였다.

  • PDF

Awareness of Integrated School Education and Education for Sustainable Development of Science Teachers in Secondary Schools with or without Common Science Teacher Qualification (중등학교 과학교사들의 공통과학 교사자격증 유무에 따른 통합과학교육과 지속가능발전교육에 대한 인식)

  • JI, Dukyoung
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.12 no.3
    • /
    • pp.224-238
    • /
    • 2019
  • The purpose of this study is to analyze the perception of integrated school education and education for sustainable development of secondary school science teachers, judging that the existence of a common science teacher qualification certificate is related to the expertise of the common science map. To that end, the survey was conducted for three months from June to August 2018 for secondary school science teachers, and multiple choice questions were analyzed as statistical processing and descriptive questions as topical modeling. According to the analysis, teachers with a common science teacher qualification certificate had a high awareness of integrated school education, and the response average was high in all areas of value, direction and success condition of integrated school education. In addition, the average response of teachers with a common science teacher qualification certificate was also found to be higher than those with a common science teacher qualification. There were no major differences in perception between the two groups on the strength of science education and ESD integration, but the difference was that teachers with a common science teaching certificate focused on science in all topics and recognized science as a medium for each topic compared to teachers who did not.

A Study on the Development of Dynamic Models under Inter Port Competition (항만의 경쟁상황을 고려한 동적모형 개발에 관한 연구)

  • 여기태;이철영
    • Journal of the Korean Institute of Navigation
    • /
    • v.23 no.1
    • /
    • pp.75-84
    • /
    • 1999
  • Although many studies on modelling of port competitive situation have been conducted, both theoretical frame and methodology are still very weak. In this study, therefore, a new algorithm called ESD (Extensional System Dynamics) for the evaluation of port competition was presented, and applied to simulate port systems in northeast asia. The detailed objectives of this paper are to develop Unit fort Model by using SD(System Dynamics) method; to develop Competitive Port Model by ESD method; to perform sensitivity analysis by altering parameters, and to propose port development strategies. For these the algorithm for the evaluation of part's competition was developed in two steps. Firstly, SD method was adopted to develop the Unit Port models, and secondly HFP(Hierarchical Fuzzy Process) method was introduced to expand previous SD method. The proposed models were then developed and applied to the five ports - Pusan, Kobe, Yokohama, Kaoshiung, Keelung - with real data on each ports, and several findings were derived. Firstly, the extraction of factors for Unit Port was accomplished by consultation of experts such as research worker, professor, research fellows related to harbor, and expert group, and finally, five factor groups - location, facility, service, cargo volumes, and port charge - were obtained. Secondly, system's structure consisting of feedback loop was found easily by location of representative and detailed factors on keyword network of STGB map. Using these keyword network, feedback loop was found. Thirdly, for the target year of 2003, the simulation for Pusan port revealed that liner's number would be increased from 829 ships to 1,450 ships and container cargo volumes increased from 4.56 million TEU to 7.74 million TEU. It also revealed that because of increased liners and container cargo volumes, length of berth should be expanded from 2,162m to 4,729m. This berth expansion was resulted in the decrease of congested ship's number from 97 to 11. It was also found that port's charge had a fluctuation. Results of simulation for Kobe, Yokohama, Kaoshiung, Keelung in northeast asia were also acquired. Finally, the inter port competition models developed by ESB method were used to simulate container cargo volumes for Pusan port. The results revealed that under competitive situation container cargo volume was smaller than non-competitive situation, which means Pusan port is lack of competitive power to other ports. Developed models in this study were then applied to estimate change of container cargo volumes in competitive relation by altering several parameters. And, the results were found to be very helpful for port mangers who are in charge of planning of port development.

  • PDF

Input Balun Design Method for CMOS Differential LNA (차동 저 잡음 증폭기의 입력 발룬 설계 최적화 기법)

  • Yoon, Jae-Hyuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.366-372
    • /
    • 2017
  • In this paper, the analysis of baluns that are inevitably required to design a differential low noise amplifier, The balun converts a single signal input from the antenna into a differential signal, which serves as an input to the differential amplifier. In addition, it protects the circuit from ESD(Electrostatic Discharge) coming through the antenna and helps with input matching. However, in the case of a passive balun used in general, since the AC signal is transmitted through electromagnetic coupling formed between two metal lines, it not only has loss without gain but also has the greatest influence on the total noise figure of the receiving end. Therefore, the design of a balun in a low-noise amplifier is very important, and it is important to design a balun in consideration of line width, line spacing, winding, radius, and layout symmetry that are necessary. In this paper, the factors to be considered for improving the quality factor of balun are summarized, and the tendency of variation of resistance, inductance, and capacitance of the balun according to design element change is analyzed. Based on the analysis results, it is proved that the design of input balun allows the design of low noise, high gain differential amplifier with gain of 24 dB and noise figure of 2.51 dB.

The Review of Exposure Index in Digital Radiography and Image Quality (디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구)

  • Yang, Sook;Han, Jae Bok;Choi, Nam Gil;Lee, Seong Gil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The aim of this study was to determine the correlation between exposure index (EI) and dose factors related to radiation dose optimization in digital radiography (DR) system. Two phantoms with built-in regional test object for quantitative assessment of images were used to produce image signals that acquired in chest radiography background. EI and entrane surface dose (ESD) increased proportionally with rise of radiation dose (kVp, mAs) in both DR and CR systems. Especially, DR detector was effective to form good contrast and hence, reached easily to improvement of image quality with minimal dose changes. It made operators possible to expect the accuracy of EI values deeply related to absorbed dose of the detector. The evaluation of images was obtained specially employed calculation of noise to signal ratio (NSR) and contrast to noise ratio (CNR). These measurements were performed for how exposure factors affect image quality. NSR was inversely proportional to kVp and mAs and low NSR represented high signal detection efficiency. Consequently, EI values was the measure of the amount of exposure received by the image receptor and it was proportional to exposure factors. Therefore the EI in a recommended range from manufacturer can offer optimal image quality. Also, continuous monitoring of EI values in the digital radiography can reduce the unnecessary patient dose and help the quality control of the system.

A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries (복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구)

  • Jang, Ji-Sung;Choi, Weon-Keun;Jung, Jae-Yon;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

The investigation of the exposure dose reduction of the Staff according to the Lead Curtain installation in EVAR(Endovascular Aneurysm Repair) surgical operation using C-arm (C-arm을 이용한 EVAR(Endovascular Aneurysm Repair) 시술시 Lead Curtain 설치에 따른 Staff의 피폭선량 감소에 대한 연구)

  • Yoo, In Woung;Chung, Jea Yeon;Lee, Kwan Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction.

  • PDF