• Title/Summary/Keyword: ESD

Search Result 471, Processing Time 0.026 seconds

High Current Behavior and Double Snapback Mechanism Analysis of Gate Grounded Extended Drain NMOS Device for ESD Protection Device Application of DDIC Chip (DDIC 칩의 정전기 보호 소자로 적용되는 GG_EDNMOS 소자의 고전류 특성 및 더블 스냅백 메커니즘 분석)

  • Yang, Jun-Won;Kim, Hyung-Ho;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.2
    • /
    • pp.36-43
    • /
    • 2013
  • In this study, the high current behaviors and double snapback mechanism of gate grounded_extended drain n-type MOSFET(GG_EDNMOS) device were analyzed in order to realize the robust electrostatic discharge(ESD) protection performances of high voltage operating display driver IC(DDIC) chips. Both the transmission line pulse(TLP) data and the thermal incorporated 2-dimensional simulation analysis as a function of ion implant conditions demonstrate a characteristic double snapback phenomenon after triggering of bipolar junction transistor(BJT) operation. Also, the background carrier density is proven to be a critical factor to affect the high current behavior of the GG_EDNMOS devices.

Electrical Properties of Multilayer Chip Varistor for ESD Protection with High Reliability. (고신뢰성 ESD보호용 칩 바리스터의 전기적 특성)

  • Yoon, Jung-Rag;Cho, Hyun-Moo;Lee, Jong-Deok;Park, Sang-Man;Lee, Young-Hie;Lee, Sung-Gap;Choe, Geun-Muk;Jeong, Tae-Seok;Lee, Seok-Won;Lee, Heon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.319-320
    • /
    • 2006
  • In order to improve the ESD(Electrical Static Discharge) resistance of multilayer chip varistors, we have investigated ZnO-$Pr_6O_{11}$ based chip varistor by applying tape casting technology, whose fundamental component were ZnO : $Pr_6O_{11}$ :$Co_3O_4$: $Y_2O_3$: $Al_2O_3$=93.67: 2.53:2.53:1.25 : 0.015 (wt %). The effect of sintering condition on the multilayer chip varistors and electric properties was studied. The electrical properties and ESD resistance of multilayer chip varistor could be influenced the sintering temperature and condition.

  • PDF

Echocardiographic Findings after Mitral Valve Replacement (승모판막치환수술 전후 심장초음파 소견의 변화에 관한 연구)

  • 이상진
    • Journal of Chest Surgery
    • /
    • v.27 no.8
    • /
    • pp.656-663
    • /
    • 1994
  • Evaluation of heart function is of importance in assessing the results of valvular heart surgery. Information on volume and functional change of heart chamber can be obtained by cardiac catheterization and echocardiography. We studied 41 patients with mitral stenosis[MS] and 23 patients with mitral regurgitation[MR] using M-mode echocardiography before and after mitral valve replacement[MVR] at Pusan Paik Hospital. Preoperative cardiac catheterization was available in 56 cases, and the results were obtained as follows. 1. In patients with MS, preoperative average LV end-diastolic dimension[EDD] and end-systolic dimension[ESD] were remained within normal range, but postoperative EDD and ESD were significantly decreased[P<0.01]. The preoperative and postoperative LV ejection fraction[EF] were remained within the normal range and no significant change[P>0.05]. The preoperative left atrial dimension[LAD] was enlarged considerably above normal[P<0.01], but was significantly decreased after surgery[P<0.001]. The preoperative LV posterior wall thickness[PWTh] was within normal range, and no significant change after surgery[P>0.05]. 2. In patients with MR, preoperative average end-diastolic dimension[EDD] and end-systolic dimension[ESD] were significantly greater than normal[P<005], but postoperative EDD and ESD were significantly decreased[P<0.01]. The preoperative LV ejection fraction[EF] and fractional shortening[FS] were within normal range, and no significant change after surgery[P>0.05].The preoperative left atrial dimension[LAD] was enlarged considerably above normal [P<0.01], but was significantly decreased after surgery[P<0.001].The preoperative LV posterior wall thickness[PWTh] was within normal range, and no significant change after surgery[P>0.05].

  • PDF

Organic Light Emitting Diodes (OLED) with Electrostatic spray deposition (ESD)

  • Hwang, Won-Tae;Kim, Nam-Hun;Xin, Guoqing;Jang, Hae-Gyu;Chae, Hee-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.432-432
    • /
    • 2010
  • Organic light emitting diodes (OLED) thin films were fabricated by Electrostatic spray deposition (ESD). In this study, we reported the thickness, morphology, current efficiency, luminescence of OLED fabricated by ESD. These results were compared with the spin coating method, and showed that also ESD is a good fabrication method for OLED because of its characteristics similar with the results using spin coating. The active layer consists of organic blends with Poly(N-vinylcarbazole) (PVK), 2-(4-Biphenyl)-5-(4-tert-butylphenyl)-1,3,4-oxadiazole (PBD), N,N'-Bis(3-methylphenyl) -N,N'-bis(phenyl)-benzidine (TPD), Tris(2-phenylpyridine)iridium(III) (Ir(ppy)3), and the structure of OLED consists of aluminum (Al), lithium fluoride (LiF), organic blends, PEDOT:PSS and Indium-tin-oxide (ITO), which was used as the top cathode, cathode interfacial layer, emitting layer and bottom anode, respectively. The results suggest that Electrostatic spray deposition is a promising method for the next generation of OLED fabrication since it has a probability fabricating large-area thin films.

  • PDF

Disc Displacement Control of the Emergency Shut-Down Valve for LNG Bunkering (LNG 벙커링용 비상차단 밸브 디스크 변위 제어에 관한 연구)

  • Yoon, Jin Ho;Park, Ju Yeon;Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.28-34
    • /
    • 2021
  • Among the currently available types of fuel, LNG emits a relatively small amount of nitrogen oxide and carbon dioxide when it burns in the engine. However, since LNG is a flammable material, leakage during bunkering can lead to accidents, such as fires. Therefore, it is necessary to install a remote operation emergency shut-down (ESD) valve to block the flow and leakage of LNG in an emergency situation that occurs during bunkering. The ESD valve uses a hydraulic driving device consisting of a hydraulic control valve and a hydraulic motor to control globe valve disc displacement, which regulates the flow path for LNG transfer. At this time, there are various nonlinearities in hydraulic driving devices; hence, it is necessary to design a controller with robust control performance against these uncertainties. In this study, modeling of the ESD valve was carried out, and a sliding mode controller to control the displacement of the globe valve disc was designed. As a result, it was confirmed that the designed control performance could be achieved by overcoming nonlinearity characteristics using the designed controller.

Efficacy and Safety of Endoscopic Submucosal Dissection for Superficial Gastric Neoplasms: A Latin American Cohort Study

  • Fernando Palacios-Salas;Harold Benites-Goni;Luis Marin-Calderon;Paulo Bardalez-Cruz;Jorge Vasquez-Quiroga;Edgar Alva-Alva;Bryan Medina-Morales;Jairo Asencios-Cusihuallpa
    • Clinical Endoscopy
    • /
    • v.55 no.2
    • /
    • pp.248-255
    • /
    • 2022
  • Background/Aims: Endoscopic submucosal dissection (ESD) is the preferred technique for treating early gastric cancer (EGC). However, very few studies have been conducted in South America. This study aimed to assess the efficacy and safety of ESD for EGC. Methods: We analyzed data from a prospective cohort from 2013 to 2020. A total of 152 superficial gastric neoplasms that fulfilled the absolute or expanded criteria for ESD were included. Outcomes were en bloc, R0, and curative resection rates, incidence of adverse events, and length of procedure. Results: The age of the enrolled patients was 68.4±11.3 years. The number of included patients based on the absolute and expanded indications was 150 and 2, respectively. En bloc, R0, and curative resections were achieved in 98.0%, 96.1%, and 89.5% of the cases, respectively. Bleeding and perforation were reported in 5.9% and 6.6% of the cases, respectively. Histopathological examination revealed low-grade dysplasia, high-grade dysplasia, well-differentiated adenocarcinoma, and poorly differentiated adenocarcinoma in 13, 20, 117, and 2 cases, respectively. Conclusions: Our study shows that ESD performed by properly trained endoscopists in reference centers is safe and effective, with comparable therapeutic outcomes to those reported in the Eastern series.

Design of Low-Area 1-kb PMOS Antifuse-Type OTP IP (저면적 1-kb PMOS Antifuse-Type OTP IP 설계)

  • Lee, Cheon-Hyo;Jang, Ji-Hye;Kang, Min-Cheol;Lee, Byung-June;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.9
    • /
    • pp.1858-1864
    • /
    • 2009
  • In this paper, we design a non-volatile memory IP, 1-kb one-time programmable (OTP) memory, used for power management ICs. Since a conventional OTP cell uses an isolated NMOS transistor as an antifuse, there is an advantage of it big cell size with the BCD process. We use, therefore, a PMOS transistor as an antifuse in lieu of the isolated NMOS transistor and minimize the cell size by optimizing the size of a OTP cell transistor. And we add an ESD protection circuit to the OTP core circuit to prevent an arbitrary cell from being programmed by a high voltage between the terminals of the PMOS antifuse when the ESD test is done. Furthermore, we propose a method of turning on a PMOS pull-up transistor of high impedance to eliminate a gate coupling noise in reading a non-programmed cell. The layout size of the designed 1-kb PMOS-type antifuse OTP IP with Dongbu's $0.18{\mu}m$ BCD is $129.93{\times}452.26{\mu}m^2$.

Clinical Outcomes of Gastrectomy after Incomplete EMR/ESD

  • Lee, Hye-Jeong;Jang, You-Jin;Kim, Jong-Han;Park, Sung-Soo;Park, Seung-Heum;Park, Jong-Jae;Kim, Seung-Joo;Kim, Chong-Suk;Mok, Young-Jae
    • Journal of Gastric Cancer
    • /
    • v.11 no.3
    • /
    • pp.162-166
    • /
    • 2011
  • Purpose: Endoscopic resection is widely accepted as standard treatment for early gastric cancer (EGC) without lymph node metastasis. The procedure is minimally invasive, safe, and convenient. However, surgery is sometimes needed after endoscopic mucosal resection (EMR)/endoscopic submucosal dissection (ESD) due to perforation, bleeding, or incomplete resection. We evaluated the role of surgery after incomplete resection. Materials and Methods: We retrospectively studied 29 patients with gastric cancer who underwent a gastrectomy after incomplete EMR/ESD from 2006 to 2010 at Korea University Hospital. Results: There were 13 incomplete resection cases, seven bleeding cases, three metachronous lesion cases, three recurrence cases, two perforation cases, and one lymphatic invasion case. Among the incomplete resection cases, a positive vertical margin was found in 10, a positive lateral margin in two, and a positive vertical and lateral margin in one case. Most cases (9/13) were diagnosed as mucosal tumors by endoscopic ultrasonography, but only three cases were confirmed as mucosal tumors on final pathology. The positive residual tumor rate was two of 13. The lymph node metastasis rate was three of 13. All lymph node metastasis cases were submucosal tumors with positive lymphatic invasion and no residual tumor in the gastrectomy specimen. No cases of recurrence were observed after curative resection. Conclusions: A gastrectomy is required for patients with incomplete resection following EMR/ESD due to the risk of residual tumor and lymph node metastasis.

ESD Design and Analysis Tools for LEO SAT (저궤도 위성의 ESD 설계 및 해석도구)

  • Lim, Seong-Bin;Kim, Tae-Youn;Jang, Jae-Woong
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.7 no.1
    • /
    • pp.68-78
    • /
    • 2009
  • In this paper, the electrostatic charging and discharging mechanism, and its effects in space plasma environment are reviewed and the system design control documents, ESD analysis tools and modelling techniques, and the SPIS program in Europe are introduced. A design of the satellite system against the electrostatic discharge (ESD) effects in space plasma environments is carefully taken into account at the early stage of development. In a view of the space system design, it really depended on the mission of system, electrical and mechanical configuration, system operation, and orbit condition. Behavior of the electrons and the ions in those environments may be occurred the sever problem to the satellite operation. So it is carefully understood for implementation of the satellite system. By this reason, the space environments and its effects have been comprehensively studied in U.S.A and Europe.

  • PDF

Design and implementation of ESD cable Disconnection Monitoring System (ESD 접지선 단선 모니터링 시스템 설계 및 구현)

  • Seong, Jung-Mo;Chung, Young-Suk;Park, Koo-Rack
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.77-82
    • /
    • 2017
  • In the splay manufacturing process, conveyor systems are widely used for conveying panels. In this conveyor, a large number of grounding lines are used in order to prevent a product failure due to static electricity. In many cases, the grounding line is disconnected due to the rotation of the transporting roller or curling, leading to product failure. In order to solve such a problem, there is a growing need for a system capable of detecting disconnection of a ground wire in real time. Therefore, in this paper, we propose a disconnection monitoring system of ESD (Electro-Static Discharge) ground wire caused by friction between the conveyor drive part and the panel. The proposed system is a monitoring system that can detect disconnection and disconnection of ground wire using ATmega 2560 and Wheatstone Bridge circuit. It can detect disconnection of ground wire immediately and can take measures to reduce the defect rate due to static electricity. The system proposed in this paper is expected to be applicable to the production and test equipments of all industries where the ground wire is used.