• Title/Summary/Keyword: EMTP-ATPDraw

Search Result 62, Processing Time 0.056 seconds

Modeling of Battery for EV using EMTP/ATPDraw

  • Kim, Jun-Hyeok;Lee, Soon-Jeong;Kim, Eung-Sang;Kim, Seul-Ki;Kim, Chul-Hwan;Prikler, Laszlo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.98-105
    • /
    • 2014
  • As environmentally friendly energy takes center stage, interests for Electric Vehicles/Plug in Hybrid Electric Vehicles (EVs/PHEVs) are getting increase. With this trend, there is no doubt EVs will take large portion to penetrations of total cars. Therefore, accurate EV modeling is required. Battery is one of the main components with the power system view of aspect. Hence, in this paper, reviews and discussions of some types of batteries for EV are contained by considering energy density and weight of the batteries. In addition, simulations of Li-Ion battery are accomplished with various variables such as temperature, capacity fading and charge/discharge current. It is confirmed that temperature is the main factor of capacity fading. Validation of the modeled battery is also conducted by comparing it with commercialized battery.

A Study on Voltage Variation in Grid-Connected Photovoltaic System using EMTP (EMTP를 이용한 태양광 발전의 계통 연계시 전압변동 분석에 관한 연구)

  • Park, June-Hee;Seo, Hun-Chul;Yeo, Sang-Min
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.241-243
    • /
    • 2008
  • 태양광 발전 기술의 발달로 용량이 증가함에 따라 계통연계가 증가하고 있다. 본 논문에서는 태양광 발전이 계통에 연계됨에 따라 기존 배전계통에 미치는 전압변동 즉, 플리커 현상을 분석하였다. EMTP/ATPDraw를 이용하여 태양광 발전이 연계된 배전계통을 모델링 하였다. 태양광 발전은 직류가 3상 PWM 인버터를 통하여 교류로 변환되어 계통에 연결되도록 모델링하였다. 태양광 array를 병렬로 연결하여 태양광 발전의 출력량을 증가시켜서, 출력변동에 따른 계통의 전압변동을 분석 하였다.

  • PDF

A Study on the Analysis of Line Constants Model in EMTP (EMTP의 선로 모델의 비교분석에 관한 연구)

  • Oh, Kwang-Wun;Yeo, Sang-Min;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2287-2288
    • /
    • 2008
  • 전력계통에는 수많은 기기가 복잡하게 연계 되어있으므로 지락사고가 일어났을 때 피해의 정도가 크다. 그래서 선로 모델링이 중요한데 선로 모델에는 많은 모델이 있기 때문에 각각의 모델들의 특성을 먼저 알아야한다. 그래서 본 논문에서는 몇 가지 선로 모델을 이용하여 모의 하여 결과를 비교해 보았다. 모의 Tool로는 EMTP/ATPDRAW를 이용하였고, 모의한 선로 모델은 Bergeron 비연가 모델, 연가 모델과 PI 등가 모델, 분포정수 모델을 이용하여 당진에서 신안성까지의 송전선로를 모델링하였다. 정상상태 일 때와 A상에서 지락사고가 일어났을 경우를 가정하고 모의하여 파형을 비교하였다.

  • PDF

Neutral Current Calculation of the One Step Type Pole using KEPCO's Distribution System (한전 실 배전계통 모델을 이용한 1단 장주 중성선 전류 계산)

  • Seo, H.C.;Park, K.W.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.;Lim, Y.H.;Seol, I.H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.35-40
    • /
    • 2007
  • The one step type and two step type pole are used in distribution line. If the three phases are not balanced, the communication line can be damaged by induced voltage. This paper calculates the neutral current using KEPCO's distribution system model which is only composed by one step type pole. The used system model is modelled by using ATPDraw and the neutral current is calculated by using EMTP/MODELS. Many cases for abstracting the neutral current characteristics in KEPCO's distribution system are simulated and analyzed.

Analysis of Switching Overvoltage on Operating Reclosing in Combined Transmission Systems (혼합송전계통에서 재폐로 시행시 개폐과전압 해석)

  • Lim, Kwang-Sik;Lee, Jong-Boem;Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.391-393
    • /
    • 2008
  • This paper is analysed by switching overvoltage on operating reclosing in 154 [kV] combined transmission systems. Combined transmission systems are modeled by EMTP/ATPDraw program. It is fault condition that simulate high resistance earth fault. The simulation is carried out considering variation of parameters such as resistance value of fault point and rate of underground line.

  • PDF

The Effects of Common Ground according to Fault Conditions in The Underground Transmission and Distribution System (고장조건에 따른 지중송배전계통에서 공통접지의 영향 분석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.285-287
    • /
    • 2007
  • This paper describes that the effect on the other system is generated by the single line to ground fault of the underground transmission systems and distribution systems established the common ground in trefoil. Each system is modeled by EMTP/ATPDraw and the system carry out simulations according to the various values of common ground to analyse. In this study, the result of analysis based on simulation suggests protection method and ground system of each system.

  • PDF

An Analysis of the Impact of the PV generation on Fuse Coordination (퓨즈협조에 대한 태양광 발전의 영향 분석)

  • Cho, Hae-In;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.474_475
    • /
    • 2009
  • Recently the grid-connected PV system is increased in the power system. According to this trend, protection coordination issues are becoming more important when the PV generation is connected to the power system. In this paper, we model the PV system using EMTP/ATPDRAW and analyze the impact of the PV generation for the fuse coordination.

  • PDF

A Detection Scheme of a Secondary Arc Extinction Using Correlation of a Fault Voltage (고장 전압의 correlation을 이용한 2차 아크 소호 판별)

  • Jang, Won-Hyeok;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.340_341
    • /
    • 2009
  • This paper suggests a detection scheme of a secondary arc extinction using the peak value of a fault voltage estimated by correlation algorithms. The system implemented in this paper is based on a Korean 765 kV system and the suggested proposed scheme is tested on the system. The performance of the method is analyzed by using Electro-Magnetic Transients Program (EMTP)/ATPDraw.

  • PDF

Neutral Current Calculation in One Step Type Pole (1단장주 중성선 전류 계산)

  • Seo, Hun-Chul;Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.480-481
    • /
    • 2006
  • This paper presents computation of the neutral torrent using KEPCO's distribution system model which is composed by only one step type poles. The used system model is modelled and simulated by using ATPDraw. And the neutral current is calculated by using EMTP/MODELS.

  • PDF

Lightning Overvoltage Analysis and Model Establishment of XLPE Cable Underneath a Bridge on Underground Power Cable Systems (지중송전계통에서 XLPE케이블의 교량첨가시 모델수립 및 뇌과전압 해석)

  • Kim, Cheol-Ho;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2243-2244
    • /
    • 2008
  • In this paper, XLPE cable underneath a bridge is modelled using EMTP/ATPDraw. Bridge section is also modelled by mutually coupled parallel conductor with XLPE cable. This paper is analysed the overvoltge by structure change of bridge section when the lightning occurs on the system.

  • PDF