• Title/Summary/Keyword: EMTDC model

Search Result 235, Processing Time 0.021 seconds

Comparison of Various Methods to Mitigate the Flicker Level of DFIG in Considering the Effect of Grid Conditions

  • Kim, Yun-Seong;Marathe, Aditya;Won, Dong-Jun
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.612-622
    • /
    • 2009
  • The short circuit ratio (SCR) of a given grid is able to show the stability of the system in the case of unwanted elements, such as wind turbulence. This paper presents the simulation of a model of the doubly fed induction generator in the simulation software PSCAD/EMTDC. This model has been used to study flicker during continuous operation and the effect of SCR and grid impedance angle on flicker emission. Simulation results show that compensation of the stator reactive power is an effective method to considerably reduce the flicker levels, irrespective of the grid conditions.

Modeling of a Variable Speed Wind Turbine in Dynamic Analysis

  • Kim, Seul-Ki;Kim, Eung-Sang;Jeon, Jin-Hong
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.2
    • /
    • pp.51-57
    • /
    • 2004
  • This paper describes the dynamic performance of a variable speed wind turbine system responding to a wide variety of wind variations. Modeling of the wind generation using power electronics interface is proposed for dynamic simulation analysis. Component models and equations are addressed and their incorporations into a transient analysis program, PSCAD/EMTDC are provided. A wind model of four components is described, which enables observing dynamic behaviors of the wind turbine resulting from wind variations. Controllable power inverter strategies are intended for capturing the maximum power under variable speed operation and maintaining reactive power generation at a pre-determined level for constant power factor control or voltage regulation control. The components and control schemes are modeled by user-defined functions. Simulation case studies provide variable speed wind generator dynamic performance for changes in wind speed

A Study on Fault of Multifunctional Battery Storage System interconnected with Distribution System (배전시스템에 연계된 다기능 전지전력저장시스템의 사고에 관한 연구)

  • Kim, Jae-Chul;Moon, Sun-Ho;Kim, In-Taek;Kim, Eung-Sang;Chu, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1244-1246
    • /
    • 1998
  • This paper present a variety fault problem brought out with the multifunctional Battery Energy Storage System [MBESS] expected to be practical in the short future interconnected to power distribution system. Multifunctional BESS model and interconnection model to power system is simply configured, the problems of protection coordination and operation is studied. A line fault in the power distribution system are discussed such as line to ground and three phase fault in order to show the impact on power utilities, demand-side and BESS-side. In order to simulate a variable transient phenomenon due to 2 the BESS interconnection operation to power distribution system, in this paper, PSCAD/EMTDC simulation tools is used.

  • PDF

A Study on Modeling of Arcing Wave for Analysis of High Impedance Fault (고저항 지락사고 해석을 위한 아크 파형 모델리에 관한 연구)

  • Moon, Sung-Chall;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1182-1184
    • /
    • 1998
  • Recently high impedance fault(HIF), which includes arcing wave, has often occured in power system. Some papers related to arcing phenomena and its modeling have been published. However the proposed methods show much different form in compare with actual arc wave under HIF. It is not so available to use to analyze HIF because of such problem. This paper proposes the new arcing wave model, which is nearly similar to actual arcing wave, developed using PSCAD/EMTDC. The arcing waves obtained from arcing model that applied in actual. power system are compared with some actual arcing wave gained from the field test and show the availability to application of relay test.

  • PDF

EMDTC model Development of Solar-Powered Hydrogen Production system (PV-SPE 시스템 최적 운전 기법에 관한 연구)

  • Lee, Dong-Han;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.274-276
    • /
    • 2005
  • This paper present an effective modeling scheme of SPE cell system for hydrogen production. As oxygen and hydrogen produced by water electrolysis using SPE are high purity, we can use oxygen in biomedical and hydrogen could be used in many ways. Recently, it is under the eye as a surplus power storage system. PSCAD/EMTDC model of SPE cell system for hydrogen production to efficiently utilize solar cell energy is showed in this paper. The simulated results are then verified by comparing them with the actual values obtained from the data acquisition system. Authors are sure that it is a useful method to the researchers who study SPE cell system for hydrogen production.

  • PDF

Harmonic analysis of Battery Energy Storage System on distribution system (전지전력저장시스템의 배전시스템 연계시 고조파 분석)

  • Kim, Young-Sung;Ryoo, Young-Don;Rim, Seong-Jeong;Kim, Jae-Chul;Kim, Eung-Sang;Ko, Yo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.856-858
    • /
    • 1996
  • This paper describes a simulation model to analyze the interconnection operation of battery energy storage system(BESS) and utility system. The computer model used to these analysis composed by using PSCAD/EMTDC. The impacts experienced at load side are studied when occur faults in utility system, and also harmonics analysis are implemented. Results of these study are available to design the harmonic filter.

  • PDF

Development of PMSG wind power system model using wind turbine simulator and matrix converter (풍력터빈시뮬레이터와 매트릭스 컨버터를 이용한 PMSG 풍력발전 시스템 모델 개발)

  • Yun, Dong-Jin;Han, Byung-Moon;Li, Yu-Long;Cha, Han-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.45-47
    • /
    • 2008
  • This paper describes development of PMSG wind power system model using wind turbine simulator and matrix converter. The wind turbine simulator, which consists of an induction motor with vector drive, calculates the output torque of a specific wind turbine using simulation software and sends the torque signal to the vector drive after scaling down the calculated value. The operational feasibility of interconnected PMSG system with matrix converter was verified by computer simulations with PSCAD/EMTDC software. The simulation results confirm that matrix converter can be effectively applied for the PMSG system.

  • PDF

A Droop Control for the Autonomous Operation of DC Distribution System using Grid-tied Converter and Energy Storage (직류급전 시스템의 Autonomous Operation을 위한 교류연계장치와 에너지 저장의 Droop Control)

  • Lee, Ji-Heon;Cha, Min-Young;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.32-33
    • /
    • 2010
  • This paper describes a droop control method for the autonomous operation of DC distribution system using distributed generations and energy storage. The method suppress the circulating current, and each unit could be controlled autonomously without communication system. Detailed model of wind power generation, photo-voltaic generation, fuel-cell generation and battery was implemented with the user-defined model of PSCAD/EMTDC software that is coded with C-language. The simulation and experimental results confirms that the proposed DC distribution system make it feasible to provide power to the load stably and verify effectiveness of the proposed method.

  • PDF

Characteristics of Interruption Ability in DC Circuit Breaker using Superconducting Coil (초전도 코일을 이용한 DC 회로 차단기의 차단 능력 특성)

  • Jeong, In-Sung;Choi, Hye-Won;Youn, Jeong-Il;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.215-219
    • /
    • 2019
  • Development of DC interruption technology is being studied actively for enhanced DC grid reliability and stability. In this study, coil type superconductor DC circuit breaker was proposed as DC interruption. It is integration technology that combined current-limiting technique using superconductor and cut-off technique using mechanical DC circuit breaker. Superconductor was applied to the coil type. In simulation, Mayr arc model was applied to realize the arc characteristic in the mechanical DC circuit breaker. PSCAD/EMTDC had used to model and perform the simulation. To find out the protection range of coil type superconductor DCCB, the working operation have analyzed based on the rated voltage of DCCB. The results confirmed that, according to apply the limiting device, the protection range was increased in twice. Therefore, the probability of failure of interruption has lowered significantly.

A Study on Development of Scaled-down HVDC Model (HVDC의 축소형 모델 개발에 관한 연구)

  • Ahn, Jong-Bo;Yun, Jae-Young;Kim, Kook-Hun;Lee, Jong-Moo;Kim, Jong-Moon;Lee, Ki-Do
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.219-221
    • /
    • 1999
  • HVDC(High Voltage Direct Current) transmission system was constructed between Cheju island and mainland Haenam and has been operating commercially since 1998. But research activities in this area are not so much. That is caused by the facts that HVDC is large scale system and it is not so easy to implement and to test. Though such simulation tools as RTDS(Real Time Digital Simulator) and EMTDC can be useful, these have limitations for actual control and protective system design. Therefore scaled-down HVDC model was developed for the purpose of researches at operating technique, control and protection methods. The design of this model was based on real Cheju-Haenam HVDC system. And additionally faults simulator such as ground fault, short-circuit and change of impedance in transmission line is equipped for analysis of these faults. Control system of the model was implemented fully digitally. So it is very easy for the researchers to develope control and protection algorithm and to test the performance.

  • PDF