• 제목/요약/키워드: EMTDC

검색결과 826건 처리시간 0.035초

PSCAD/EMTDC를 이용한 PV Cell 및 MPPT 모델링에 관한 연구 (Simplified PV Cell and MPPT Modeling based on PSCAD/EMTDC)

  • 장수;최준호;조정섭;박인권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1118_1119
    • /
    • 2009
  • The power generated by a Photovoltaic(PV) cell depends on the operating voltage of the array, its voltage-current and voltage-power characteristic curves specify a unique operating point at which maximum possible power is delivered and the array is operated at its highest efficiency. PSCAD/EMTDC, which is a simulation tool for the transient analysis of an electric power system, was used to simulate the PV Cell system. So, in this paper, the PV cell components of the PSCAD/EMTDC were developed, and the Maximum Power Point Tracking(MPPT) modeling was used for the developed PV power system to find the maximum power.

  • PDF

PSCAD/EMTDC를 활용한 COMTRADE 기반의 교류철도 급전계통 사고 데이터 분석에 관한 연구 (A Study of Analysis of Fault Data in AC Electrical Railway Power System Based on COMTRADE Using PSCAD/EMTDC)

  • 이지혜;민명환;안태풍;이병곤
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1542-1548
    • /
    • 2018
  • When any faults occurred in electrical railway system, operators need to analysis it quickly and accurately. Existing COMTRADE based analysis tools are not enough to analysis faults occurred in electrical railway system. In this paper, it presents some functions to fault analysis for electrical railway system based on fault data formatted COMTRADE. These functions are implemented in PSCAD/EMTDC and it can be shown that analyzed results against actual electrical fault cases which were occurred in the electrical railway power system.

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2193-2194
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic (PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.561-562
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic(PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power Quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD) The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

PSCAD/EMTDC를 이용한 저항형 초전도한류기의 계통적용분석 연구 (A Study on the Application Analysis of the Resistive type Superconducting Fault Current Limiters using PSCAD/EMTDC)

  • 허태전;방종현;배형택;박민원;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권1호
    • /
    • pp.25-31
    • /
    • 2005
  • Since the discovery of the high temperature superconductors many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means In limit fault current in power systems. HTS resistive type SFCL is based on the ultra fast transition from the superconducting (non resistive) state to the normal (resistive) state by overstepping the critical current density, In this study, the simulation method of resistive type superconducting fault current limiter using EMTDC is proposed and the developed EMTDC model of SFCL is applied to the modeled power network using the Parameters of real system.

저항형초전도한류기 과도특성을 고려한 EMTDC 모델개발 (Development of EMTDC model for Resistance type Fault Current Limiter considering transient characteristic)

  • 윤재영;김종율;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.1-7
    • /
    • 2003
  • Nowadays, one of the serious problems in KEPCO(Korea Electric Power Co-Operation) system is the more higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(High Voltage Direct Current-Back to Back) and FCL(fault current limiter). But, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the HTS-FCL(High Temperature Superconductor -Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. Under this background, this paper presents the EMTDC(Electro-Magnetic Transient Direct Current) model for resistance type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching phenomena occur.

EMTDC로 구현한 제주-해남 HVDC 시스템의 사고모의 및 AC Protection (Fault Simulation and AC side Protection of Cheju-Haenam HVDC using EMTDC)

  • 박상호;전영수;김수열;임성주;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.372-374
    • /
    • 2002
  • 제주-해남 HVDC 시스템의 #1, #2 Pole이 동시 운전 중에 동기조상기가 탈락할 경우, HVDC시스템의 운전모드 절체와 제주기력 #2, #3호기의 출력변화 등을 EMTDC 프로그램으로 시뮬레이션 하였다. 또한 HVDC 시스템의 AC측 보호계전기를 계전 알고리즘을 이용하여 EMTDC 모델로 구현하고 제주 교류계통에서 사고 발생시 HVDC 시스템의 보호를 검토하였다.

  • PDF

계통연계형 연료전지 모델링에 관한 연구 (A Study of Fuel Cell Modeling for Interconnected Power Systems)

  • 이종수;윤석무;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.502-503
    • /
    • 2008
  • The modelling of PEMFC(Proton Exchange Membrane Fuel Cell) has been studied in many kinds of methods. But there are some limitations in application of the developed models to analysis transient phenomena of power systems. The PSCAD/EMTDC is very popular simulation tool in power system areas. To analysis power systems interconnected to PEMFCs, the PSCAD/EMTDC model of the PEMFCs is needed. In this paper, we developed a PSCAD/EMTDC model of PEMFC based on electro-chemical characteristic equations of PEMFC. Also, we performed simulations using the developed model in the PSCAD/EMTDC program and tested appropriateness of the proposed the models. The simulations showed good results.

  • PDF

PSCAD/EMTDC를 이용한 교류 전철급전시스템 모델링 (Modelling AC Electric Railway System using the PSCAD/EMTDC)

  • 이한민;창상훈;한문섭;김주락;오광해;이장무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.260-262
    • /
    • 2002
  • This study presents a AC electric railway system model using PSCAD/EMTDC. Ver.3.08 for circuit analysis and fault studies. This system model made by PSCAD/EMTDC is composed of feeder, contact line, rails, Scott-transformer, Auto-transformer. This model is based on four-port network which is an extension of two-port network theory. In order to verify the proposed model, each voltage of feeder-rail, contact line-rail and feeder-contact line is measured and fault studies are also simulated.

  • PDF

초전도 한류기를 포함한 계통의 지락사고에 대한 EMTDC 해석 (An EMTDC Analysis for Ground Faults with a Superconducting Fault Current Limiter)

  • 최효상;현옥배;고태국
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권4호
    • /
    • pp.161-166
    • /
    • 1999
  • We have performed an EMTDC simulation for the current limiting effects of a superconducting fault current limiter (SFCL). The fault currents in the 154 kV transmission line between the arbitrary S1 and S2 substations increased up to 39 kA during the single and double line-to-ground faults, respectively. The SFCL in the transmission line is sufficient.

  • PDF