• Title/Summary/Keyword: EMTDC

Search Result 826, Processing Time 0.027 seconds

Modeling and Simulation of Superconducting Transformer using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 초전도 변압기의 모델링과 시뮬레이션)

  • 임채형;박민원;유인근
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.33-38
    • /
    • 2004
  • This paper presents an effective simulation method for the high temperature superconducting (HTS) transformer using PSCAD/ EMTDC. Although researches and developments are performed for the HTS technologies, problems such as AC loss and quench phenomenon need to be solved for efficient design of HTS transformer. In addition, pre-study on the HTS transformer is a sort of time and cost consuming work, thus it is very worthy or being analyzing the characteristics of the HTS transformer in advance through a proper simulation method. It is very important to analyze the HTS devices by the simulation for seeking suitable and reasonable parameters for the practical application of those apparatuses in advance. A software- based component is suggested for- the simulation of the HTS transformer using PSCAD/ EMTDC and the numerical results are analyzed in detail in this paper.

A UPFC Simulation using the EMTDC (EMTDC를 이용한 UPFC Simulation)

  • 송의호;전진홍;조동길;전영환;김학만
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.291-298
    • /
    • 2001
  • This paper deals with a full functional simulation of UPFC (Unified Power Flow Controller) which is a next generation FACTS (Flexible AC Transmission Systems) technology. Through analysis and modeling of he UPFC, power flow control is simulated. Active and reactive power controls, and input side bus voltage control are performed by EMTDC (Electro-Magnetic Transients in DC systems) which is a general purpose time domain simulation program for simulating power systems transients and its controls. Dynamic performances of the UPFC are verified by simulation results.

  • PDF

Development of KERISIM model and contingency analysis using EMTDC (EMTDC를 이용한 KERISIM 모델개발 및 상정사고 해석)

  • Yoon, Jae-Young;Moon, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.91-93
    • /
    • 2000
  • KERISIM(KERI Simulator)은 한국전기연구소가 개발한 회전기형 시뮬레이터로서 AC/DC 비동기 연계계통을 포함한 복합계통의 다양한 동태현상에 대한 분석이 가능하다. 본 논문에서는 한국전기연구소의 전력계통 분석용 시뮬레이터에 대한 EMTDC 해석모델을 개발하고 이를 활용하여 상정사고 해석을 수행함으로써 제어기 설계를 위한 성능시험을 할 수 있는 기본 바탕을 마련하였다. 즉, KERISIM을 구성하고 있는 개별 기기들의 설계사양을 기술하였으며, EMTDC 해석모델의 구성요소들을 살펴보았다. 이와 같이 개발된 EMTDC 모델를 활용하여 Rectifier 및 Inverter측 교류모선에서 3상고장 상정사고 해석을 수행하였으며, 그 해석결과를 분석하였다.

  • PDF

A Novel Simulation model of Solar Cell using EMTDC (EMTDC를 이용한 태양전지의 새로운 시뮬레이션 모델)

  • Park, Min-Won;Kim, Bong-Tae;Lee, Jae-Deuk;Yu, In-Keun;Sung, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.113-115
    • /
    • 2000
  • So far, it was very difficult to simulate the dispersed generation system including PV generation system using EMTP or EMTDC because the source of the dispersed generation system has a particular VI characteristic equation. In this paper, a novel simulation method of PV generation system has proposed and a new solar cell component for EMTDC is also developed. The VI characteristic equation of solar cell is used in order to realize the solar generation system in EMTDC simulation. Consequently the simulation of PV power generation system using field data is realized and acceptable results, which show close match between the real data of PV panel and the simulated data, were obtained.

  • PDF

Model development of electrified railroad supply system for Electromagnetic Transient Analysis (순시치 해석용 전철급전계통 모델개발)

  • 윤재영;최흥관;김종율;위상봉
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.4
    • /
    • pp.253-259
    • /
    • 2002
  • This paper presents the first simulation model using EMTDC program to analyze the electrified train voltage distribution characteristics in ac auto-transformer fed railroads. In general, all of the electrified train supply system has the characteristics that the train supply line is a naturally non-symmetrical and unbalanced system. Also, it is needed to model the Scott transformer which invert the balanced 3-phase quantity into 2-phase. Therefore, the general simulation methodology using previous simplified equivalent circuit or RMS based program can't obtain the accurate results to reflect the real-time operation because these methodology is basically assumed on completely 3-phase balanced system. To overcome these defects, in this paper, the EMTDC simulation model to analysis the completely electrified railroad system with Scott transformer and AC auto-transformer is presented. Also, the correctness of EMTDC modeling is confirmed by the old basic concepts and we think that this EMTDC model has the future powerful capability for application of railroad system analysis.

The PSCAD/EMTDC Modelling of JeJu AC Power System

  • Shuai, Zang;Choi, Joon-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.252-254
    • /
    • 2008
  • In this paper, the PSCAD/EMTDC modeling of JeJu AC power system with wind farms will be discussed. And the modelling of the synchronous generator, exciter, governor will also be defined in the JeJu power system by using the PSCAD/EMTDC. At the same time the fault analysis and the power flow analysis in JeJu AC power system are presented to demonstrate the JeJu AC power system can perfectly simulate the real JeJu power system function. Through the simulation using PSCAD/EMTDC we have gained the same results compared with the results accomplished by the PSS/E. so the validity of the modelling for the JeJu power system by using PSCAD/EMTDC is confirmed.

  • PDF

The Analysis of 80MVA UPFC application effect using EMTDC (PSCAD/EMTDC 80MVA UPFC 계통적용 효과 분석)

  • Yoon, Jong-Su;Park, Sang-Ho;Lim, Seong-Joo;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.259-262
    • /
    • 2001
  • 본 논문은 2003년 한전 실계통(154kV 강진 S/S)에 적용예정인 80MVA UPFC(Unified Power Flow Controller)시스템의 동적특성을 EMTDC/PSCAD를 이용하여 분석한 결과이다. UPFC는 FACTS 기기중 전압, 임피던스, 위상각등 전력전송 제어를 위한 송전선로의 모든 파라미터를 동시에 독립적으로 제어 할 수 있는 FACTS기기[1]로서, 미국 Inez S/S, Marcy S/S에 이어 강진 S/S에 80MVA 용량의 UPFC가 실계통 적용될 예정이다. 본 논문은 과도현상 해석 프로그램인 PSCAD/EMTDC를 이용하여 80MVA UPFC 제어기와 적용 대상 계통인 강진 S/S 인근 계통을 모델링하고 상정사고에 대한 UPFC 제어효과 분석에 대하여 기술하였다. 적용된 EMTDC UPFC모델은 실제 80MVA UPFC 기기에 채용된 전력회로, 제어기, 보호시스템과 동일하게 모델링하였으며 적용 대상계통은 PSS/E 해석결과와 동일하도록 강진 S/S인근 계통을 축약 등가화한 계통모델을 사용하였다.

  • PDF

Development of SeoDaeGu SVC Control System Using EMTDC (EMTDC를 이용한 서대구 SVC 제어시스템 개발)

  • Kim, Yong-Hak;Cha, Seung-Tae;Kim, Tae-Kyun;Yoon, Yong-Beum;Choo, Jin-Bu
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.75-80
    • /
    • 2001
  • EMTDC가 FACTS 기기와 같이 전력전자소자가 포함된 계통을 신뢰성 있게 해석 할 수 있고 또한 다양한 제어기능과 각종 스위칭 소자 모델을 제공 하기때문에 실계통에서 운용되고 있는 서대구 SVC 제어시스템을 EMTDC로 개발하였다. 모델 개발을 위하여 서대구 SVC의 제작사인 ABB에서 제공한 서대구 SVC의 기능, 구성 및 특성을 분석하였으며 개발된 EMTDC SVC 제어시스템 모델의 신뢰성을 검증하기 위하여 제작사에서 제공한 TNA 테스트 결과와 비교하여 모델의 정확성을 검증하였다.

  • PDF

The Analysis of 80MVA UPFC application effect using EMTDC (EMTDC를 이용한 80MVA UPFC(Unified Power Flow Controller) 계통적용 효과 분석)

  • Yoon, Jong-Su;Chang, Byung-Hoon;Oh, Kwan-Il;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.93-96
    • /
    • 2001
  • 본 논문은 2003년 한전 실계통(154kV 강진 S/S)에 적용예정인 80MVA UPFC(Unified Power Flow Controller) 시스템의 적용효과를 EMTDC/PSCAD 프로그램을 이용하여 분석한 결과이다. UPFC는 현재까지 개발된 FACTS 기기중 전압, 임피던스, 위상각등 전력전송 제어를 위한 송전선로의 모든 파라미터를 동시에 제어 할 수 있는 유일한 FACTS기기[1]로서 미국 Inez S/S에 이어 세계 두번째로 강진 S/S에 80MVA 용량의 UPFC가 실계통 적용될 예정이다. 본 논문은 대표적인 과도현상 해석프로그램인 EMTDC를 이용한 80MVA UPFC의 적용시 계통 제어효과 분석에 대하여 기술하였다. 적용된 EMTDC UPFC모델은 실제 80MVA UPFC 기기 전력회로, 제어기와 동일하게 모델링하였으며 적용 대상계통은 한전 계통 데이터를 바탕으로 강진 S/S인근 계통을 축약 등가화한 계통모델을 사용하였다.

  • PDF

EMTDC Modeling of Cheju-Haenam HVDC System (제주-해남 HVDC 시스템의 EMTDC 모델링)

  • 김찬기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • This paper deals with HVDC simulation. And the purpose of this paper is to reproduce measurements recorded at HVDC site and to verify the control gains and control actions. In this paper, the target of simulation study is Cheju-Haenam HVDC system. Because Cheju-Haenam HVDC system include analogue controller and digital controller, the detailed digital model considered nonlinear characteristics of analogue controllers is development for high accurate firing and control action. Finally the simulation results which is simulated by PSCAD/EMTDC is compared with measurement signals.