• 제목/요약/키워드: EMI emission

검색결과 81건 처리시간 0.031초

42″ AC-PDP의 방사특성에 대한 연구 (Investigation on Radiation Characteristics of 42″ AC-PDP)

  • 임헌용;김민석;박동욱;이정해
    • 한국전자파학회논문지
    • /
    • 제15권9호
    • /
    • pp.841-847
    • /
    • 2004
  • EMI emission characteristics of 42" AC-PDP panel are investigated in this paper. First, EMI emission source was modeled the scan electrode and the sustain electrode to a simple electric and magnetic dipole type radiator. Second, EMI emission source was modeled as reconfigured the scan electrode and the sustain electrode. The primary source of EMI emission was investigated using FEM calculation of the wave impedance and 3 dB beam width. The third. the EMI emission level was estimated using the measured sustain electrode current. Also, EMI emission level of 42" AC-PDP was measured. The results show that the calculated EMI emission level from the simple electric dipole model was shown to agree with that from the corresponding FEM simulation.

3상 PWM 컨버터의 전도성 EMI 특성에 관한 연구 (A Study on Conducted EMI Emission Characteristics in 3-Phase PWM Converter)

  • 채영민;고재석;목형수;최규하;홍순찬;백수현;이은웅
    • 전력전자학회논문지
    • /
    • 제2권2호
    • /
    • pp.41-48
    • /
    • 1997
  • 최근 고품질 전원공급에 관한 요구가 증대되면서 장치에서 발생되는 고차 고조파에 의하여 다른 기기의 오동작을 방지하기 위한 EMI(Electro Magnetic Interferencfe)에 관한 연구가 전력전자분야를 중심으로 활발하게 진행되고 있다. 따라서 본 논문에서는 3상 전력변환 장치인 다이오드 정류기와 PWM 컨버터에서 PI 전류제어방식과 히스테리시스 전류제어방식을 대상으로 LISN(Line Impedance Stabilization Network)을 사용하여 제어방식의 변화와 스위칭 주파수 변동에 따른 전도성 EMI 방출량을 측정하여 비교하였다.

  • PDF

A Study of Electromagnetic Emission of 42' AC PDP Module

  • Lim, Hun-Yong;Kim, Min-Seok;Lee, Jeong-Hae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.752-755
    • /
    • 2003
  • An EMI emission of 42" AC-PDP panel is studied in this paper. First, the EMI emission level is roughly estimated using both simple electric dipole type and magnetic dipole type radiator model. The value of current required for estimation has been obtained from Fourier Transform of the measured current in time domain. Second, we investigate which type of EMI radiation is dominant by FEM calculation of the wave impedance. The result shows that electric dipole type radiation is dominant EMI source.

  • PDF

Three-Phase Common-Mode Active EMI Filters for Induction Motor Drive Applications

  • Tarateeraseth, Vuttipon
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.871-878
    • /
    • 2018
  • In this paper, the conducted EMI reduction performances of active feed-forward current-sensing current-actuation (CSCA) and voltage-sensing current-actuation (VSCA) filters for a three-phase induction motor drive system are evaluated by experiments. For comparison purposes, the conducted EMI (CM emission, DM emission and total emission) of a three-phase induction motor drive with a conventional CM choke, a conventional CM choke in series with an active VSCA filter, and an active CSCA filter (where the CM choke was modified and used as a sensing current transformer) were compared to the case of a system without any filter inserted. Experimental results show that the active CSCA and VSCA filters can improve the CM reduction performance of the conventional CM choke by about 5 dB especially at low-frequencies. However, for DM comparisons, it shows that there is no different between cases with and without filters inserted.

전원부 잡음제거용 광대역 EMI filter의 설계 (Design of a Broadband EMI filter to Suppress the Noise from the Power Supply)

  • 신은철;강승택;장건호;박창림
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1576_1576
    • /
    • 2009
  • We present the design of an EMI filter to mitigate the electrical noise from the power supply over a broadband of a few tens of KHz to 18GHz. Admitting that our approach is not apart from the standard technology of EMI filter, it is worth checking out how we can implement the filter that meets the challenging spec. on band of operation. The function of the EMI filter is well-depicted by its performance on the CE(Conducted Emission) and RE(Radiated Emission) suppression through tests which convince us of its application to power supplies of land, water and flying vehicles.

  • PDF

지상탱크의 부식감지를 위한 음향방출시험에서 발생한 전자기간섭신호의 특성 연구 (A Study on the Characteristics of Electronic Magnetic Interference(EMI) in Acoustic Emission Testing for Corrosion Detection of Ground Tank)

  • 김승대;정우광
    • 한국재료학회지
    • /
    • 제17권5호
    • /
    • pp.239-243
    • /
    • 2007
  • The evaluation and comparison have been made for the EMI noise which was included in the signal from the sensors in the acoustic emission testing for the bottom plate of ground tank at full. The EMI signal has been classified into two types. One is the signal with very short AE count, and this signal possibly can be filtered by front end filter setting of the channel count with low level of 4 and high level of $10^8$. The other EMI signal occurred from CH 1, CH 3 and CH 10, and had high and constant duration with high energy and count (maximun duration > $10^5\;{\mu}s$), and has characteristic gradient of accumulation amplitude distribution. This signal should be removed in the AE signal evaluation by filtering, because this may affect to the total gradient.

Conducted Emission of Inverter Power Sources for Resistance Welding

  • Mecke, H.;Dobbelin, R.;Winkler, T.;Fischer, W.
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.124-129
    • /
    • 2002
  • Invertigation electromagnetic emissione of inverter power sources resistance welding existing special aspects of EMI measurements in the field of resistance welding machines resulting from the power rating and operation mode of these machines have to be taken into account. The characteristics of the internal switching processes determined by the behavior of the applied power semiconductors, sunbber circuits and constructional aspect exert a great influence on the conducted emission welding inverters.

3상 다이오드 정류기의 고조파 해석 및 LISN을 이용한 노이즈 측정에 관한 연구 (Harmonic Analysis of Three-Phase Diode Rectifier and Measurement of Conducted EMI Emission Using LISN)

  • 채영민;최규하;목형수;이은웅;홍순찬;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.212-215
    • /
    • 1995
  • In this paper, The characteristic of Harmonic spectrum is studied for generally used three-phase diode rectifier. and filter design criteria is showen in the sense of THD, DPF, and PF. As the becoming of Automative and informative era, the demand of critical and stable control becomes more and more important. But much EMI emissions are generated for more critical and stable control in power electronic system these EMI emissions can be measured using LISN(Line Impedance Stabilization Network). So we are to investigate the behavior of Conducted EMI emission in Diode Rectifiers using LISN in frequency domain.

  • PDF

EMI 저감을 위해 분할된 전원/접지 평판 구조에서의 방사성 방출 분석 (Analysis of Split Power/Ground Plane Structures for Radiated EMI Reduction)

  • 이장훈;이필수;이태헌;김창균;송인채;위재경
    • 대한전자공학회논문지SD
    • /
    • 제47권6호
    • /
    • pp.43-50
    • /
    • 2010
  • 본 논문에서는 시스템 모듈에서 발생하는 EMI를 줄이기 위해 분할된 전원/접지 평판 구조에 의해 발생하는 방사성 방출(Radiated emission)을 분석하였다. 분석을 위해 다양한 조건을 갖는 시험 기판(Test board)에 대한 자기장과 전기장을 시뮬레이션하고 측정하여 비교하였다. 이 분석 결과는 입력 신호의 주파수 대역에서 반사계수의 위상이 $0^{\circ}$에 근접하도록 하며, 입력 신호의 주파수와 분할된 전원/접지 평판 구조의 공진주파수가 일치하지 않도록 분할된 접지 갭의 폭과 위치를 결정함으로써 방사성 방출을 줄일 수 있음을 보여준다. 또한, 스티칭 커패시터(Stitching capacitor)를 사용하여 방사성 방출을 저감시킬 수 있으며, 방사성 방출을 효과적으로 저감시키기 위해 입력 신호의 주파수에서 반사계수의 크기를 낮추고 위상이 $0^{\circ}$에 근접하도록 스티칭 커패시터의 값과 위치를 결정할 필요가 있음을 알 수 있다.

변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구 (A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area)

  • 민문기;이재기;박진엽;김희제
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.