• 제목/요약/키워드: EMG-measurement

검색결과 175건 처리시간 0.022초

The Effect of Fatigue on EMG Activity and Dynamic Balance of Subjects with Functional Lumbar Instability

  • Kim, Myong-Chul;Kim, Ho-Sung
    • The Journal of Korean Physical Therapy
    • /
    • 제27권4호
    • /
    • pp.207-213
    • /
    • 2015
  • Purpose: The aim of the current study was to investigate EMG activity on dynamic balance of subjects with functional lumbar instability following fatigue of low back. Methods: The subjects (24 university students) were divided into 2 groups; functional lumbar instability group (6 males and 6 females) and lumbar stable group (7 males and 5 females) who could complete a questionnaire and undergo a prone instability test. All participants were evaluated for distribution of muscle activity using the TeleMyo DTSTM system. Dynamic balance was tested by Y balance test. This study was conducted for measurement of EMG activity on dynamic balance with the difference between FLIG and control group following muscle fatigue. Results: The functional lumbar instability group (FLIG) showed a significantly lower YBT score (%) of anterior, posterolateral direction on Y-balance test (YBT) in dynamic balance than the lumbar stable group (LSG) (p<0.05). The FLIG was significantly lower than the LSG in anterior direction in EMG activity(%) of MF, RA, ES, GMX, GME, RF, and posteromedial direction in EMG activity(%) of IO, ES and then posterolateral direction in EMG activity(%) of IO, ES in dynamic balance (p<0.05). There was significant correlation of MF, RA, and GMX in anterior reach direction (p<0.05) and ES, GME (p<0.01) and IO, ES in posteromedial reach direction (p<0.05) and EO, ES, GMX in posterolateral reach direction (p<0.05) there was positive correlation. Conclusion: This study showed that FLIG effected EMG activity by dynamic balance following muscle fatigue. Further study is needed for measurement of various ages and work with lumbar instability for clinical application.

얼굴근전도와 얼굴표정으로 인한 감성의 정성적 평가에 대한 연구

  • 황민철;김지은;김철중
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1996년도 춘계학술대회논문집
    • /
    • pp.264-269
    • /
    • 1996
  • Facial expression is innate communication skill of human. Human can recognize theri psychological state by facial parameters which contain surface movement, color, humidity and etc. This study is to quantify or qualify human emotion by measurement of facial electromyography (EMG) and facial movement. The measurement is taken at the facial area of frontalis and zygomaticus The results is indicative to discriminate the positive and negative respond of emotion and to extract the parameter sensitive to positive and negative facial-expression. The facial movement according to EMG shows the possibility of non-invasive technique of human emotion.

  • PDF

다중 생체 신호 기반 보행 단계 감지 및 판단 (Gait Phases Detection and Judgment based Multi Biomedical Signals)

  • 김서준;정의철;송영록;윤광섭;이상민
    • 재활복지공학회논문지
    • /
    • 제6권2호
    • /
    • pp.43-48
    • /
    • 2012
  • 본 논문에서는 Electromyogram(EMG) 신호와 허벅지 각도 측정 장치, 발바닥 저항 센서를 이용하여 보행의 단계를 판단하는 방법을 제시한다. 신호의 측정을 위하여 건강한 성인 남성 5명을 대상으로 실험을 실시하였고 정상 보행에서의 EMG, 허벅지 각도, 발바닥 저항 센서를 통한 변화를 측정 하였다. EMG 신호의 획득을 위하여 실험자의 대퇴 사두근, 대퇴 이두근, 전경골근, 장딴지근에 Ag/AgCl 표면 전극을 부착하였으며, 양측 발뒤꿈치와 앞꿈치에 저항센서를 부착 하였다. 허벅지 각도 측정 장치는 굴곡 25도, 신전 20도 까지 범위를 가지며 이를 통하여 허벅지의 각도를 측정 하였다. 실험 결과 보행 시 입각기와 유각기를 명확히 판단 할 수 있었으며 세부적으로 8단계의 보행 상태를 판단 할 수 있었다.

  • PDF

복부 근전도 분석을 통한 복부 비만 측정 시스템 (Measurement System of Abdominal Obesity based on Analysis of Abdominal Electromyogram)

  • 권장우;최흥호;이동훈;윤동업;홍준의
    • 재활복지공학회논문지
    • /
    • 제1권1호
    • /
    • pp.45-52
    • /
    • 2007
  • 최근 각종 질환의 원인이 되고 있는 비만은 심각한 사회문제로 대두되고 있으며, 이를 해결하기 위해 비만 관리를 위한 측정 시스템의 필요성이 증가하고 있다. 본 논문은 비만관리를 위해 복부의 근전도 신호를 분석해서 언제 어디서든 본인의 건강상태를 체크하여 적절한 의료 서비스를 받을 수 있는 측정 시스템에 관한 연구이다. 복부 근전도 선호 분석을 위해서 에너지 검출, 신호 특징 추출, 상태 분류 및 인식 등을 위한 알고리즘을 제안한다. 이 신호 분석 알고리즘을 측정 시스템에 적용하여 복부의 비만도 및 복부의 근력을 평가하여 건강상태에 대한 적절한 평가를 제공하는 시스템을 제안한다.

  • PDF

작업부하에 따른 생리적 반응들에 관한 연구 (A Study of Physical Responses for Work Loads)

  • 김재현;김홍기
    • 산업경영시스템학회지
    • /
    • 제25권1호
    • /
    • pp.9-13
    • /
    • 2002
  • The objective of this study was to analyze and make comparison between the physical responses such as oxygen consumption rate, heart rate, and EMG-measurement for lifting tasks. Lifting activities with three different working frequencies(5, 8, 11 lifts/min) and two different weights(10, 20kg) for a lifting range(from floor to 76cm height) were studied. It was found that theme are positive correlations between the oxygen consumption rate and the EMG-measurements on the region of law back. Even though these physical responses were influenced by work weights and work frequency, it was found that the work frequency plays more important role in making muscle fatigue than the work weight. From these finding it is suggested that the work frequency should be considered as a more influencing factor than the work weight as long as the weight belongs to the permissible range based on the viewpoint of the biomechanical criterion for designing a job of manual materials handling tasks.

윈도우 환경하에서 근전도의 실시간 Silent Period 측정 시스템 설계 (A Design of Real Time Measurement System for EMG Silent Period Under Window Base)

  • 강병길;김태훈;이영석;김덕영;김세동;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권10호
    • /
    • pp.611-617
    • /
    • 2003
  • A mechanical or electrical stimulation to the mandibular symphysis during a maximal voluntary clenching of the teeth always produces a jaw jerk followed by a silent period (transient stops) in the masseteric EMG (electromyogram). Generally, a mechanical stimulation is followed by a single silent period, and an electrical stimulation is followed by multiple silent periods. In this paper, we propose a new algorithm for determining the duration of the masseter silent period. The decision approach in essentially based upon a segmentation algorithm consisted of variance filter, median filter and gaussian filter. The new adaptive digital notch filter using R-CLMS(reverse constrained least mean-squared) algorithm is proposed for the elimination of powerline(60Hz) noise. At the same time, we design a real time measurement system for the EMG silent period under Window base.

상용 제스처 컨트롤러의 근전도 패턴 조합에 따른 인터페이스 연구 (A Research for Interface Based on EMG Pattern Combinations of Commercial Gesture Controller)

  • 김기창;강민성;지창욱;하지우;선동익;쉐강;신규식
    • 공학교육연구
    • /
    • 제19권1호
    • /
    • pp.31-36
    • /
    • 2016
  • These days, ICT-related products are pouring out due to development of mobile technology and increase of smart phones. Among the ICT-related products, wearable devices are being spotlighted with the advent of hyper-connected society. In this paper, a body-attached type wearable device using EMG(electromyography) sensors is studied. The research field of EMG sensors is divided into two parts. One is medical area and another is control device area. This study corresponds to the latter that is a method of transmitting user's manipulation intention to robots, games or computers through the measurement of EMG. We used commercial device MYO developed by Thalmic Labs in Canada and matched up EMG of arm muscles with gesture controller. In the experiment part, first of all, various arm motions for controlling devices are defined. Finally, we drew several distinguishing kinds of motions through analysis of the EMG signals and substituted a joystick with the motions.

수직 진동을 동반한 Leg Press 운동 시 진동 크기와 주파수에 따른 하지 근육의 근전도 차이 분석 (Difference in sEMG on lower extremity during leg press exercise with whole body vibration with various amplitude and frequency)

  • 최진승;김용준;강동원;문경률;탁계래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1492-1495
    • /
    • 2008
  • As a prerequisite of developing muscle biofeedback system which can simulate analogous isokinetic exercise, the purpose of this study was to study the effects of frequency and amplitude of whole-body vibration on the difference in sEMG on lower extremities during leg press exercise with/without vibration. The amplitude of vibration was set to 20, 50, 80 and the frequency of vibration was set to 10, 20, 30, and 50 Hz. EMG were measured at Vastus lateralis muscle and Vastus medialis muscle. MP100 EMG module(BIOPAC system Inc., USA) was used for EMG measurement. The result showed that the combination of frequency of 30Hz and amplitude of 50 had more activated EMG than other combination with relatively small work load (30kg). It is necessary to experiment the frequency between 20 and 40Hz in detail, and to normalize sEMG using maximal voluntary contraction (MVC).

  • PDF

반복적인 손목 및 손가락 작업에서의 수작업 부하 평가 (Evaluation of manual workload in repetitive wrist and finger motion)

  • 권오채;윤명환
    • 대한인간공학회지
    • /
    • 제18권2호
    • /
    • pp.103-120
    • /
    • 1999
  • The purpose of this study was to evaluate the manual workload in repetitive wrist and finger motion. To evaluate manual workload, angular displacement of the joint, EMG of the muscle and subjective rating were studied. Both wrist motion and finger motion were studied. A screw-driving task was used for the wrist motion experiment. A keyboard typing task was used for the finger motion experiment. All finger joint angles and wrist angles were measured by an angle-measuring glove($CyberGlove^{TM}$, Virtual Technologies, Inc.). Surface EMG was recorded from FCU muscle and FDS muscle simultaneously with the angle measurement. Subjective ratings of exertion were also recorded using the modified Borg's CR-10 scale. Repetition rates of 0.5, 1, 2 motions per second were used with each task. As a result, manual workload increased with increasing repetitiveness. Peak spectral magnitude and frequency components corresponded closely with joint angular displacement amplitudes and repetition rates. Results of the correlation analysis showed that there were significant correlation among EMG, frequency-weighted motion and subjective measurement. Both EMG and frequency-weighted filtering showed consistent workload estimation with increasing task frequency. Subjective ratings showed slight over-estimation of the workload as the task frequency is increased.

  • PDF

근 질환자의 표면 근전도 신호에 대한 근섬유 전도속도 측정방법 (A measurement method of muscle fiber conduction velocity for surface EMG signal of muscle diseased patient)

  • 이진;정정균;신승현;박인선;고현윤;김성환
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.35-38
    • /
    • 1997
  • A new approach to the measurement of muscle fiber conduction velocity by surface electro-myography(EMG) is developed, based upon a robust time-delay estimation algorithm. Unlike previously reported methods, it does not require the Gaussian assumption of raw EMG signal, and can be applied accurately in non-gaussian impulsive EMG signal. For ive healthy subjects the conduction velocity in the biceps brachii and vastus medialis was measured and compared with various other techniques. As a result, the average muscle fiber conduction velocity was $4.59{\pm}0.20m/s$ in case of biceps brachii and $5.67{\pm}0.33m/s$ in vastus medialis.

  • PDF