• Title/Summary/Keyword: EMC

Search Result 970, Processing Time 0.025 seconds

Warpage Analysis during Fan-Out Wafer Level Packaging Process using Finite Element Analysis (유한요소 해석을 이용한 팬아웃 웨이퍼 레벨 패키지 과정에서의 휨 현상 분석)

  • Kim, Geumtaek;Kwon, Daeil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.1
    • /
    • pp.41-45
    • /
    • 2018
  • As the size of semiconductor chip shrinks, the electronic industry has been paying close attention to fan-out wafer level packaging (FO-WLP) as an emerging solution to accommodate high input and output density. FO-WLP also has several advantages, such as thin thickness and good thermal resistance, compared to conventional packaging technologies. However, one major challenge in current FO-WLP manufacturing process is to control wafer warpage, caused by the difference of coefficient of thermal expansion and Young's modulus among the materials. Wafer warpage induces misalignment of chips and interconnects, which eventually reduces product quality and reliability in high volume manufacturing. In order to control wafer warpage, it is necessary to understand the effect of material properties and design parameters, such as chip size, chip to mold ratio, and carrier thickness, during packaging processes. This paper focuses on the effects of thickness of chip and molding compound on 12" wafer warpage after PMC of EMC using finite element analysis. As a result, the largest warpage was observed at specific thickness ratio of chip and EMC.

Study on Runoff Characteristics of Non-point Source in Rural Area of Seomjin Watershed (섬진강 유역 농촌지역의 비점오염원 배출특성에 관한 연구)

  • Park Sung-Chun;Oh Chang-Ryol;Jin Young-Hoon;Kim Dong-Soo
    • Journal of Environmental Science International
    • /
    • v.14 no.11
    • /
    • pp.1057-1062
    • /
    • 2005
  • The present study investigated runoff characteristics of non-point pollutants and discharge load amount according to the land utilization in Yeinam river basin. The land utilization of target basin was divided into paddy field, dry field, forest, residential area and composition area. The study on the runoff characteristics of non-point pollutants by rainfall-runoff process showed that COD, SS and T-P had the first-flushing effect with relatively high concentration in early-stage of the rainfall-runoff process, but the T-P revealed similar runoff characteristics. Event Mean Concentration(EMC) of BOD and COD according to the land utilization revealed the range of $3.11\~15.50mg/L$ and $3.37\~33.42mg/L$, and the highest concentration of EMC corresponding to BOD and COD was detected in the paddy field. The EMC of SS showed $1.7\~305.02mg/L$ and it's highest concentration was found in the dry field. The EMC of T-N and T-P represented the highest concentration in the paddy field and dry field with range of $0.91\~8.76mg/L$ and $0.02\~0.44mg/L$.

An Analysis on Situation of Broadcasting and Telecommunication Equipment EMC Test Market and Way of Government Intervention (방송통신기자재 전자파 시험 시장의 현황 분석 및 정부 개입 방안)

  • Lee, Yong-Kyu;Kim, Young-Rae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.753-762
    • /
    • 2013
  • This paper forecast that, if the EMC test market for broadcasting and communication materials and equipment reaches a saturated state, such will give rise to adverse effects such as capture phenomenon, rent seeking phenomenon, and stiff test price competition; this in turn will eventually wield a negative impact on our society. Thus, to determine the saturation level of EMC test markets, the size of test markets and test capabilities of the designated laboratories were surveyed. As a result, the operation rate of equipment in the EMC test markets was revealed to be 78 %, suggesting market saturation. Moreover, the wireless, wire, and SAR equipment operation rates reached 65 %, 3 %, and 10 %, respectively, suggesting market saturation. Thus, maintaining the strictness of testing requires limiting the designation of new test laboratories; in light of practices and implementation of laws, however, the relevant administrative agency has difficulty rejecting applications for the designation of laboratories.

Evaluation of KOMPSAT-2 System in the Conducted EMC Environment (전도성 전자파환경에서의 다목적실용위성 2호 시스템 설계 검증)

  • Kim, Tae-Youn;Lim, Seong-Bin;Choi, Seok-Weon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.138-144
    • /
    • 2004
  • Satellite generates a complex electromagnetic noise by conducted and radiated coupling effect of the various electrical instruments. This noise may cause serious problems on the satellite system. To minimize the electromagnetic coupling effects and maintain the system safety margin, system noise reduction technique should be applied from the beginning of the system design. The KOMPSAT-2 system is evaluated by measuring the conducted noise on system electrical power leads and verifying a 6dB system safety margin under the complex noise environment with current injection. This paper describes the KOMPSAT-2 system evaluation result performed on ETB(Electrical Test Bed) and the analysed noise element, the analysed result will be reflected on FM(Flight Model) EMC test.

Characteristics of Non-Point Pollution Discharge of Urban Area According to Land Use (토지이용도에 따른 도시하천의 비점오염원 유출특성)

  • Park, Sung-Chun;Oh, Chang-Ryol;Kim, Jung-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1229-1233
    • /
    • 2005
  • 본 연구는 도시지역의 강우-유출로 인한 비점오염물질의 유출특성 및 배출부하량을 조사하기 위하여 영산강권역의 풍영정천을 대상으로 조사하였다. 대상 유역의 토지이용별 구분은 논지역, 하류공단 및 논$\cdot$산지 복합 토지 이용특성, 공단 지역, 도시 분류식 지역, 소유역 출구지역으로 구분하였다. 시료의 채취는 강우시 4회에 걸쳐 조사하였으며, 매회 시료 채취 주기는 강우유출이 발생하기 전부터 시작하여 첨두유출량이 발생때까지 $1\~2$시간 간격으로 채취한 후 강우 종료 후 유출량 변화가 없을 때까지 $9\~12$단계로 세분하여 유출량과 pH, DO, BOD, COD, SS, T-N, T-P의 농도를 측정 하였다. 토지이용별 비점오염물질의 유량가중평균농도(EMC : Event Mean Concentration)를 살펴보면, BOD의 EMC는 $4.43\~14.22mg/{\ell}$의 분포를 보였으며, 도시 합류식 토지이용 특성을 지닌 P-4지점에서 가장 큰 농도를 보였을 뿐만 아니라 타 토지이용 특성에 비하여 두드러지게 초기 오염물질 유출 현상을 나타내었다. COD의 EMC는 $8.27\~18.81mg/{\ell}$의 분포를 보였으며, BOD 수질농도와 같이 P-4 지점에서 가장 큰 농도를 갖는 것으로 나타났다. SS의 EMC는 $35.76\~358.86mg/{\ell}$의 분포를 보였으며, 소유역의 중간지점이면서 논$\cdot$산지$\cdot$공단지역의 토지이용 특성을 지닌 P-2 지점에서 가장 큰 농도를 나타내었다. 이는 조사기간(Event 1, Event2) 동안 상류의 자연형하천 제방공사로 인한 토사유출로 인하여 다소 높게 나타난 것으로 판단된다. 또한, 대상유역 전반적으로 초기 오염물질 유출 현상을 보였으며, BOD와 COD 수질농도의 분포양상과는 다르게 강우량 및 강우강도에 많은 영향을 받는 것으로 나타났다. T-N의 EMC는 $1.61\~7.13mg/{\ell}$의 분포를 보였으며, T-P는 $0.03\~0.46mg/{\ell}$의 분포를 갖는 것으로 나타났다.

  • PDF

Determination of Pollutant EMCs and Loadings of Runoff in Paved Areas (포장지역내 강우유출수의 EMCs 및 부하량 산정)

  • Gil, Kyung-Ik;Wee, Seung-Kyung;Park, Moo-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.119-122
    • /
    • 2008
  • The paved area like a road or bridge where having high impermeable rates were accumulated various non-point sources(NPS) by passing vehicles during dry season periods. They are flowed in the river continuous when it rains and could negative impact on environment. Therefore, this study monitoring NPS for two years and determinating for each pollutant EMCs and mass loading. The result shows that the EMC ranges are 11.60$\sim$230.90 mg/L for TSS, 4.58$\sim$31.90 mg/L for BOD, 1.86$\sim$9.20 mg/L for TN and 0.14$\sim$1.55 mg/L for TP. Also, the ranges of washed-off mass loading are determined to 0.78$\sim$18.01 kg/day for TSS, 0.47$\sim$1.17 kg/day for BOD, 0.00$\sim$0.01 kg/day for Pb and 0.01$\sim$0.06 kg/day for Zn.

Effect of the Chemical Treatment and Fiber Length of Kenaf on Physical Properties of HDPE/Kenaf/Expandable Microcapsule (HDPE/케나프/열팽창성 마이크로 캡슐의 물성에 미치는 섬유 길이 및 화학처리 영향)

  • Ku, Sun Gyo;Lee, Jong Won;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.27 no.3
    • /
    • pp.270-275
    • /
    • 2016
  • High density polyethylene (HDPE)/kenaf fiber (KF) composites included two types of KF with different lengths were fabricated by using a twin screw extruder. A thermally expandable microcapsule (EMC) was used to form HDPE/KF. The KF lengths were 0.3 mm and 3 mm. The contents of KF and EMC were fixed at 20 wt% and 5 wt%, respectively. From FT-IR data of KF, which underwent chemical treatment, peaks around 1700 and $1300cm^{-1}$ decreased. This might be caused by the reduction of lignin and hemicellulose due to the chemical treatment of KF. Based on the specific gravity, thermal stability and tensile property, physical properties of the composites with a 3 mm fiber were good. However, if the fiber is longer, poor appearance might be caused due to the thermal degradation during processing. Thus, the adequate length of KF should be chosen to maintain the appearance and physical properties for industrial applications of HDPE/KF/EMC composites. The tensile strength for 0.3 mm fiber treated with chemicals increased slightly.

Annual Variation in Temperature, Relative Humidity and Equilibrium Moisture Content of Wood in Indoor (옥내(屋內)의 온도(溫度), 상대습도(相對濕度)와 목재(木材) 평형함수율(平衡含水率)의 연중(年中) 변이(變異))

  • Jung, Hee-Suk;Lee, Nam-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.4
    • /
    • pp.540-544
    • /
    • 1994
  • Equilibrium moisture contents(EMC) were calculated based on temperature and relative humidity of atmosphere and actual EMCs were measured at intervals of ten days in previous air-dried wood samples for seven different species including Douglas fir and oaks in four indoor locations in central region for one year. Mean annual air temperature and relative humidity were $23.3^{\circ}C$ and 54.9% in bedroom, $22.4^{\circ}C$ and 59.5% in living room of apartment, $20.1^{\circ}C$ and 57.0% in office room and 19.4 and 64.0% in living room of tile-roofed house, respectively. Mean annual calculated and actual EMCs were 10.2 and 9.7% in bedroom, 11.1 and 10.2% in living room of apartment, 10.7 and 10.4% in office room, and 12.1 and 12.5% in living room of tile-roofed, house, respectively. Actual EMC of kasai were higher than average value of EMC for seven species. However, those of sycamore and apitong were lower than average value.

  • PDF

Determination of EMC and MFFn Rainfall Runoff in Songcheon, Doam Lake Watershed (도암호 유역 송천에서의 강우유출수 분석을 통한 EMC와 초기세척비율 (MFFn) 산정)

  • Kwon, Hyeokjoon;Kim, Jonggun;Lim, Kyoungjae;Kim, Dongjin;Hong, Eunmi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.13-22
    • /
    • 2020
  • The Doam Lake watershed has a significant impact on the downstream water system due to nutrients and sediment outflow during rainfall caused by steep slopes, soil losses, and fertilization. These non-point sources are unclear in the discharge area and are affected by land use patterns, soil characteristics, and topographical features of the watershed. Therefore, this study conducted rainfall monitoring from July to October 2019 in Songcheon upstream of the Doam Lake watershed, one of the non-point pollution source management areas. Then, after analyzing rainfall runoff, Event Mean Concentration (EMC) and Mass First Flush ratio (MFFn) were calculated to compare and analyze the characteristics of rainfall and the non-point pollutant discharge. As a result of the analysis, it showed various non-point pollutant emission characteristics for each rainfall event. In addition, the concentration of EMC and the MFFn were affected by the average rainfall intensity and the maximum rainfall intensity, and were not significantly affected by the number of antecedent drying days. In the future, it is expected that effective non-point source reduction measures and management measures according to rainfall intensity through continuous monitoring and analysis will be needed.

Management Plan on EMC for Functional Safety of the ISO26262 (자동차 기능 안전성(ISO26262)에 관한 EMC 관리계획)

  • Shin, Jaekon;Chung, Yeonchoon;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.10
    • /
    • pp.1020-1027
    • /
    • 2014
  • ISO 26262 is applied to vehicle and electrical/electronic component manufacturers for minimizing car accidents and life damage by the extended use of electronic control equipments and their malfunctions. In this standard, safety requirements are required to be applied from the early stage of development upto manufacture and disposal stages throughout the total lifecycle of the full vehicular system, and electromagnetic compatibility must be also managed as an important consideration factor. Therefore, it is nowadays very necessary to research and develop EFS(EMC for Functional Safety) to be applied in each stage of the design, manufacture, accreditation, use, maintenance stages of cars. In this paper, how EFS can be applied for the application of ISO 26262 is described. By the enforcement of this suggestions into the legal requirement or New Car Assessment Program(NCAP) test items, it is necessary that car manufacturer have to perform some procedures for ensuring car safety by themselves.