• Title/Summary/Keyword: EEG measurement

Search Result 165, Processing Time 0.03 seconds

Development and Practical Application of a Psychological Skill Training Program for National Wheelchair Curling Players -Frontal EEG Asymmetry (휠체어컬링 국가대표선수의 경기력 향상을 위한 심리기술훈련 프로그램의 개발 및 적용 -EEG 뇌파활용 연구)

  • Kim, Sung-Woon;Choi, Seok Lip;Kim, Han-Cheol
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.3
    • /
    • pp.275-290
    • /
    • 2019
  • The present study aimed to develop a sports psychological skill training program and to test its applicability to improve the performance of national wheelchair curling players. A total of 4 participants completed the study. Subjects have been to 12 sessions of 6 different psychological skills training programs (routine training, attentional focus training, writing practice training in diary, relation training, self-control training, and positive self-talk training). The effectiveness of psychological skills training has been evaluated with 6 questionnaires and EEG measurement. The result was that psychological skills training had improved coping with adversity, peaking under pressure, and concentration, self-management and reduced anxiety of Korean national wheelchair curling player. The result was that the EEG inter-hemispheric asymmetry index showed negative emotional states before psychological skill training but positive emotional states after. The result implies that psychological skill training plays an important mediating role in bringing about positive effects in the psychological elements and competitiveness in national wheelchair curling players.

1/f scaling exponent of EEG depending on different sensitivities of behavioral activation and inhibition systems for young and elderly groups (청년층과 노인층의 행동활성화체계 및 행동억제체계 민감도에 따른 뇌파의 1/f 스케일링 분석)

  • Jin Seung-Hyun;Kim Wuon-Shik;Noh Gi-Young
    • Science of Emotion and Sensibility
    • /
    • v.8 no.4
    • /
    • pp.415-422
    • /
    • 2005
  • The purpose of the present study was to investigate the differences of nonlinear characteristics of electroencephalogram (EEG) depending on different sensitivities of behavioral activation system (BAS) and behavioral inhibition system (BIS) of young and elderly groups. The EEGs from Fpl and Fp2 electrodes were recorded during resting condition. The young and elderly groups consisted of 19 and 31 healthy right-handed volunteers, respectively. We estimated 1/f scaling exponent which reflects the nonlinear dynamical complexity of EEG. As results, we found the differences of 1/f scaling exponent between young ant elderly BAS sensitive groups. The 1/f scaling exponent of young BAS sensitive group showed significantly higher values than those of elderly BAS sensitive group at the left prefrontal area (Fpl). The young BAS sensitive group had also a tendency to higher 1/f scaling exponent at the right prefrontal area (Fp2). Decrease of the 1/f scaling exponent indicates the increase of complexity and the decrease of the amount of information related to the statistical distribution. Therefore, the elderly BAS sensitive group has higher complexity than young BAS sensitive group, though they were all classified as BAS sensitive group by BAS/BIS scale. Our results suggest the possibility of correlation between BAS sensitivity an4 age.

  • PDF

The effects of Fire point(LR2).Water point(LR8) through Reinforcement-Reduction acupuncture stimulation on ANS & EEG (족궐음간경(足厥陰肝經)의 화혈(火穴)과 수혈(水穴)의 침보사(針補瀉)가 자율신경계와 뇌파에 미치는 영향)

  • Kang, Hee-Chul;Lee, Seung-Gi
    • Journal of Oriental Neuropsychiatry
    • /
    • v.21 no.2
    • /
    • pp.87-101
    • /
    • 2010
  • Objectives : The aim of this experiment was to investigate the influences of Autonomic Nervous System and EEG by conducting Reinforcement-Reduction(補瀉) acupuncture stimulation to compare the changes in acupoints on the body before and after treatment of acupuncture at Xingjian(LR2) being referred as Fire-point(火穴) and Ququan(LR8) being referred as Water-point(水穴) of Yin Liver Meridian(足厥陰肝經). Methods : This study was carried out on 30 healthy female volunteers in their 20's. There were four tests conducted throughout and the period for each test was between 2 to 5days. HRV and EEG were measured for 5 minutes before acupuncture stimulation was conducted on LR2-Reinforcement, LR2-Reduction, LR8-Reinforcement and LR8-Reduction at random. During the 20 minutes of acupuncture treatment, same subjects were measured simultaneously to observe any significant changes in acupoints. Again, the same subjects were measured for 5 minutes after removing the acupuncture in order to perform a comparative analysis. Results : The measurement of HRV showed that LF, LFnorm and LF/HF ratio increased significantly(p<0.05) while HF, HF norm decreased significantly in case of LR2-Reinforcement & LR8-Reduction. Both LR2-Reduction and LR8-Reinforcement induced a significant increase in HFnorm. EEG measurement indicated low $\alpha$ wave decreased and high $\beta$ wave increased significantly at LR2-Reinforcement during post-acupuncture period compared with acupuncture stimulation period. Both LR2-Reduction and LR8-Reinforcement developed significantly low $\alpha$ wave and high $\alpha$ wave. High $\beta$ wave increased significantly at LR8-Reduction during the acupuncture stimulation in comparison with pre-acupuncture period. Conclusions : The manipulation of acupuncture stimulation at LR2-Reinforcement and LR8-Reduction enhanced the activity of sympathetic nerves and the state of arousal while that of para sympathetic nerves declined. On the other hand, LR2-Reduction and LR8-Reinforcement developed the levels of para sympathetic nerves and relaxation.

The development of a bluetooth based portable wireless EEG measurement device (블루투스 기반 휴대용 무선 EEG 측정시스템의 개발)

  • Lee, Dong-Hoon;Lee, Chung-Heon
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.16-23
    • /
    • 2010
  • Since the interest of a brain science research is increased recently, various devices using brain waves have been developed in the field of brain training game, education application and brain computer interface. In this paper, we have developed a portable EEG measurement and a bluetooth based wireless transmission device measuring brain waves from the frontal lob simply and conveniently. The low brain signals about 10~100${\mu}V$ was amplified into several volts and low pass, high pass and notch filter were designed for eliminating unwanted noise and 60Hz power noise. Also, PIC24F192 microcontroller has been used to convert analog brain signal into digital signal and transmit the signal into personal computer wirelessly. The sampling rate of 1KHz and bluetooth based wireless transmission with 38,400bps were used. The LabVIEW programing was used to receive and monitor the brain signals. The power spectrum of commercial biopac MP100 and that of a developed EEG system was compared for performance verification after the simulation signals of sine waves of $1{\mu}V$, 0~200Hz was inputed and processed by FFT transformation. As a result of comparison, the developed system showed good performance because frequency response of a developed system was similar to that of a commercial biopac MP100 inside the range of 30Hz specially.

EEG Recording Method for Quantitative Analysis (정량적 분석을 위한 뇌파 측정 방법)

  • Heo, Jaeseok;Chung, Kyungmi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.397-405
    • /
    • 2019
  • Quantitative electroencephalography (QEEG) has been widely used in research and clinical fields. QEEG has been widely used to objectively document cerebral changes for the purpose of identifying the electrophysiological biomarkers across various clinical symptoms and for the stimulation of specific cortical regions associated with cognitive function. In electroencephalography (EEG), the difference in quantitative and qualitative analyses is discriminated not by its measurement methods and relevant clinical or research environments, but by its analysis methods. When performing a qualitative analysis, it is possible for a medical technologist or experienced researchers to read the EEG waveforms to exclude artifacts. However, the quantitative analysis is still based on mathematical modeling, and all EEG data are included for the analysis, leading the results to be affected by unexpected artifacts. In the hospital setting, the case that the medical technologists in charge of the EEG test perform academic research has been little reported, compared to other clinical physiological measurement-based research. This is because there are few laboratories specialized in clinical physiological research. In this respect, this study is expected to be utilized as a basic reference material for medical technologists, students, and academic researchers, all of whom would like to conduct a quantitative analysis.

Interval estimate of physiological fluctuation of peak latency of ERP waveform based on a limited number of single sweep records

  • Nishida, Shigeto;Nakamura, Masatoshi;Suwazono, Shugo;Honda, Manabu;Nagamine, Takashi;Shibasaki, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.1.1-5
    • /
    • 1994
  • In the single sweep record of event-related potential (ERP), the peak latency of P300, which is one of the most prominent positive peaks in the ERP record, might fluctuate according to the recording conditions. The fluctuation of the peak latency (measurement fluctuation) is the summation of the fluctuation caused by physiological factor (physiological fluctuation) and one by noise of background EEG (noise fluctuation). We propsed a method for estimating the interval of the physiological fluctuation based on a limited number of single sweep records. The noise fluctuation was estimated by using the relationship between the signal-to-noise (SN) ratio and the noise fluctuation based on the P300 model and the background EEG model. The interval estimate of the physiological fluctuation were obtained by subtracting the interval estimate of the noise fluctuation from that of the measurement fluctuation. The proposed method was tested by using simulation data of ERP and applied to actual ERP and data of normal subjects, and gave satisfactory results.

  • PDF

Practical Use Technology for Robot Control in BCI Environment based on Motor Imagery-P300 (동작 상상-P300 기반 BCI 환경에서의 로봇 제어 실용화 기술)

  • Kim, Yong-Honn;Ko, Kwang-Eun;Park, Seung-Min;Sim, Kwee-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.227-232
    • /
    • 2013
  • BCI (Brain Computer Interface) is technology to control external devices by measuring the brain activity, such as electroencephalogram (EEG), so that handicapped people communicate with environment physically using the technology. Among them, EEG is widely used in various fields, especially robot agent control by using several signal response characteristics, such as P300, SSVEP (Steady-State Visually Evoked Potential) and motor imagery. However, in order to control the robot agent without any constraint and precisely, it should take advantage of not only a signal response characteristic, but also combination. In this paper, we try to use the fusion of motor imagery and P300 from EEG for practical use of robot control in BCI environment. The results of experiments are confirmed that the recognition rate decreases compared with the case of using one kind of features, whereas it is able to classify each both characteristics and the practical use technology based on mobile robot and wireless BCI measurement system is implemented.

Measurement of EEG and Analysis of Stress Change in Space Using Virtual Reality - Focus on the Hitler's residence - (가상현실을 활용한 공간에서의 뇌파 측정과 스트레스 변화량 분석 - 히틀러 총통관저를 중심으로 -)

  • Kim, Sun-Uk;Kang, Se-Yeon;Ji, Seung-Yeul;Jun, Han-Jong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.8
    • /
    • pp.73-79
    • /
    • 2019
  • The purpose of this study is to analyze the stress variation according to Hitler's residence using EEG data. Hitler's residence, one of the most monumental buildings, is designed as a grand and overbearing space, giving the visitor a sense of psychological pressure when moving from a high space to low space. Based on the above background, this paper constructs Hitler's residence using virtual reality and measure the changes of the beta waves which are known to be related with stress when the floor level moves from high to low space in Hitler's residence built in virtual space. The results of the experiment are as follows; when moving from high to low space, the subjects' stress was high and at the same time brain waves variation was increased greatly due to changes in space.

The Effect of Manual Acupuncture on the Waves of the Electroencephalogram -Typical Electrodes and Correlation Analysis between Wave Form- (자침수기가 뇌파에 미치는 영향 -대표도자 및 파형 간의 상관관계 분석을 중심으로-)

  • Yoon, Ga-Young;Lee, Seung-Deok;Han, Seung-Moo;Kim, Tae-Min;Seon, Jong-In;Kang, Jung-Won;Nam, Dong-Woo;Choi, Do-Young;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.28 no.3
    • /
    • pp.131-142
    • /
    • 2011
  • Objectives : The primary purpose of this study was to examine the effect of manual acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ on normal human EEG (Electroencephalogram). And the secondary purpose of this study was to analyze the relationships between the change of EEG wave form using correlation analysis. Methods : 32 channel EEG measurement was carried out in 25 healthy participants (23 males and 2 females). EEG was measured for 21 minutes including 15 minutes of retention time. In this study, power spectrum was used as a measure of complexity. Statistical analysis was performed using Spearman correlation. Results : The results were as follows; 1. In C4, O1, Fz, Pz, Cz, FCz, CP4, FC4, TP7, FT7 among 32 electrodes, ${\delta}$, $\theta$ and ${\beta}$ wave increased during 0-3 time intervals, and especially in case of TP7, FT7 ${\alpha}$ wave spontaneously decreased during 12~15 time intervals in manipulation group. 2. Between $\theta$ and ${\beta}$ wave and $\theta$ and ${\delta}$ wave, there was statistically significant positive correlation in C4, O1, Fz, Pz, Cz, FCz, CP4, FC4, TP7, FT7 according to Spearman correlation analysis. 3. Between ${\alpha}$ and ${\beta}$ wave, there was statistically significant positive correlation in TP7, FT7 according to Spearman correlation analysis. Conclusions : These results suggest that TP7 and FT7 could be typical electrodes representing change of EEG after manipulated acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$. The relationships between the change of EEG wave form appear to have statistically significant positive correlation between $\theta$ and ${\beta}$ wave, $\theta$ and ${\delta}$ wave and ${\alpha}$ and ${\beta}$ wave.