• Title/Summary/Keyword: EDGE

Search Result 10,780, Processing Time 0.046 seconds

Position of maxillary central incisor and intercanine width in Korean adults (한국 유치악 성인의 상악 중절치 위치 및 견치간 거리에 관한 연구)

  • Yang, Dong-Hun;Lee, Jee-Yun;Ban, Jae-Sam;Oh, Gye-Jeong;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.147-152
    • /
    • 2013
  • Purpose: The aim of this study was to propose the position of maxillary anterior teeth and intercanine width measurements based on the incisive papilla in accordance with the cephalic type and gender of dentate Korean adult with normal teeth alignment. Materials and methods: 42 students with Class I normal occlusion, without crowding or spacing, were selected from the Chonnam National University School of Dentistry. The lateral skull radiographs of the subjects were taken and were classified as different cephalic types, based on their PFH / AFH ratios. 42 casts of their maxilla were prepared and both the distance between the upper central incisors and the middle of the incisor papilla was measured with a vernier caliper (A) and the distance between the maxillary canine cusp tips (B) were measured. Statistical analysis was performed using SPSS version 15 and their significance was investigated. Results: For dolichocephalic group, the mean values for A and B were 8.43 (SD: 0.61) and 36.73 (SD: 2.17), respectively. The mean value for A was 8.51 (SD: 1.27) for the mesocephalic group and 8.76 (SD 1.03) for the brachycephalic group. The mean value for B was 35.91 (SD: 1.86) for the mesocephalic group and 37.34 (SD: 2.23) for the brachycephalic group. For the male group, the mean A value was 8.86 (SD: 1.04) and the mean B value was 37.60 (SD: 0.24). For the female group, the mean A value was 8.41 (SD: 0.93) and the mean B value was 36.18 (SD: 2.01). The difference between male and female group in A values were not statistically significant (P>.05). The B values of the male subjects were greater than those of the female subjects and was statistically significant (P<.05). Conclusion: 42 students with normal dentition and occlusion in korea, the distance from the incisive papilla and the incisal edge of maxillary central incisors had no difference in cephalic type or gender. However, the distance between the cusp tip of both canines had significant difference in gender where the male showed higher values than the female, while having no difference in cephalic types.

Effects of Surface Finishes on the Low Cycle Fatigue Characteristics of Sn-based Pb-free Solder Joints (금속패드가 Sn계 무연솔더의 저주기 피로저항성에 미치는 영향)

  • Lee, Kyu-O;Yoo, Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.3
    • /
    • pp.19-27
    • /
    • 2003
  • Surface finishes of PCB laminates are important in the solder joint reliability of flip chip package because the types and thicknesses of intermetallic compound(IMC), and compositions and hardness of solders are affected by them. In this study, effects of surface finishes of PCB on the low cycle fatigue resistance of Sn-based lead-free solders; Sn-3.5Ag, Sn-3.5Ag-XCu(X=0.75, 1.5), Sn-3.5Ag-XBi(X=2.5, 7.5) and Sn-0.7Cu were investigated for the Cu and Au/Ni surface finish treatments. Displacement controlled room temperature lap shear fatigue tests showed that fatigue resistance of Sn-3.5Ag-XCu(X=0.75, 1.5), Sn-3.5Ag and Sn-0.7Cu alloys were more or less the same each other but much better than that of Bi containing alloys regardless of the surface finish layer used. In general, solder joints on the Au/Ni finish showed better fatigue resistance than those on the Cu finish. Cross-sectional fractography revealed microcracks nucleation inside of the interfacial IMC near the solder mask edge, more frequently on the Cu than the Au/Ni surface finish. Macro cracks followed the solder/IMC interface in the Bi containing alloys, while they propagated in the solder matrix in other alloys. It was ascribed to the Bi segregation at the solder/IMC interface and the solid solution hardening effect of Bi in the $\beta-Sn$ matrix.

  • PDF

The Clinical Analysis of Sulcus Vocalis (성대구증에 관한 임상적 고찰)

  • 김광문;서장수;오혜경;최홍식;김기령
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.11.2-12
    • /
    • 1982
  • The major advancement in phonosurgery due to recent development of laryngomicrosurgery enabled more accurate diagnosis and treatment of patient with voice disorders. Among large proportion of voice disordered patients, prominent linear furrow running parallel along the free edge of vocal cord extending from the vocal process to anterior commissure can be seen as well as incomplete closure during phonation. These cases were illustrated and coined as sulcus vocalis by Salvi in 1901, since then other similar paper was reported in Europe and Japan, but has not been reported in Korea. The exact etiology and therapeutic methods of sulcus vocalis has not been elaborated. At Department of Otolaryngology of Yonsei University College of Medicine a series of voice analysis were performed among those 35 patients with sulcus vocalis visited to Vocal Dynamics Laboratory from May, 1981 to March, 1982. Following is the result of clinical statistical investgation and therapeutic modality. 1) The incidance of sulcus vocalis among 290 patients with voice disorder visited to Vocal Dynamics Laboratory was approximately 12%(35 cases). 2) Onset of this voice disorder was most frequent among patient under 10 year-old groups; 19 cases (54%) followed by second decade, third decade groups in decreasing frequency respectably. 3) The etiology of sulcus vocalis was mostly unknown. The sequelae after measle (4 cases) and severe upper respiratory infection (3 cases) and congenital deformity (2 cases) were the possible causes of sulcus vocalis. 4) These patients were involved bilaterally in 25 cases (71%), left side only in 8 cases (23%) and right side only in 2 cases (6%). 5) Almost all patients complained hoarseness and 7 patients were suffering from chronic laryngitis. 6) In aerodynamic analysis, Maximal Phonation Time was decreased in 20 cases (57%), Phonation Quotient was increased in 22 cases (63%) and Mean Air Flow Rate was increased in 23 cases (66%). 7) Among them, 33 cases were analyzed with stroboscopy. The findings were as follows; incomplete glottic closure during phonation in 31 cases (93%), regular vocal cord movement in whole cases, asymmetric cord movement in 4 cases (12%), decreased amplitude in 5 cases (21%) and small mucosal wave in 24 cases (73%). 8) Intracordal Teflon injection in 5 cases and Sulcusectomy in 1 cases were performed as therapeutic management, however, the therapeutic results were not effective except one case with Teflon injection.

  • PDF

Annual Occurrent Pattern of Scirtothrips dorsalis (Thysanoptera: Thripidae) on Citrus Trees and Surrounding Host Plants (감귤원과 그 주변 기주식물에서 볼록총채벌레의 연중발생 양상)

  • Song, Jeong Heub;Kim, Chang Seog;Yang, Young Taek;Hong, Soon Yeong;Lee, Shin Chan
    • Korean journal of applied entomology
    • /
    • v.52 no.3
    • /
    • pp.185-191
    • /
    • 2013
  • The damage of citrus by Scirtothrips dorsalis Hood appears to have increased since 2007 in Jeju, although the characteristics of seasonal abundance are not clear. This study was conducted to investigate the relationship between host plants and the seasonal abundance of S. dorsalis, observing plants distributed around citrus orchards. The host plants of S. dorsalis surrounding citrus orchards were determined to include 32 families, 54 species: 39 woody plant species and 15 herbaceous plant species. The host plants which related to the occurrence of 1st generation of S. dorsalis were Lonicera japonica, Clematis apiifolia, Hedera rhombea, and Viburnum awabuki. The occurrence of 1st generation S. dorsalis was estimated to be due to overwintered female adults having laid eggs into those plants from late March to early April, and the new adults having emerged from late April to late May. The host plants which were associated with fruit damage of citrus were Mallotus japonicus, and Camellia japonica, as well as creeping plants such as Clematis apiifolia, Paederia scandens and Cayratia japonica. The adult phase density of S. dorsalis caught on yellow-color sticky traps placed on the citrus trees on the edge of the citrus orchard. S. dorsalis were predominantly 3rd generation from late of June to early of July, and 6th generation from late of August to early of September, and their numbers were directly related to the degree of damage caused to the citrus fruit. The density of S. dorsalis depended on the number of new growing shoots of host plants, which indicated that the immigration of adults of S. dorsalis to the citrus was based in the suitability of host plants surrounding the orchards.

Performance of Collaboration Activities upon SME's Idiosyncrasy (중소기업 특성에 따른 외부 협업 활동이 혁신성과에 미치는 영향)

  • Lee, Hye Sun;Oh, Junseok;Lee, Jaeki;Lee, Bong Gyou
    • Journal of Internet Computing and Services
    • /
    • v.14 no.6
    • /
    • pp.95-105
    • /
    • 2013
  • Recently, SME's Collaboration activities have become one of a vital factor for sustaining competitive edge. This is because of the rapidly changing and competitive market environment, and also to leverage performance by overcoming obstacles of having limited internal resources. Discussing about the effects and relationships of the firm's collaboration activities and its outputs are not new. However, as ICT and various technologies have been diffused into the traditional industries, boundaries and practice capabilities within the industries are becoming ambiguous. Thus contents of the products/services and their development methods are also go and come over the industries. Although many researchers suggested the relations of SME's collaboration activities and innovation performances, most of the previous literatures are focusing on broad perspectives of firm's environmental factors rather than considering various SME's idiosyncrasy factors such as their major product and customer types at once. Therefore, the purpose of this paper is to analyze how SME(Small Medium Enterprise)'s external collaboration activities by their idiosyncrasy act as an input to types of innovation performance. In order to analyze collaboration effects in detail, we defined factors that can represent the SME's business environment - Perceived importance of using external resources, Perceived importance of external partnership, Collaboration and Collaboration levels of Major Product types, Customer types and lastly the Firm Sizes. We have also specifically divided the performance of innovation types as product innovation and process innovation based on existing research. In this study, the empirical analysis is based on Probit Regression Model to observe the correlations with the impact of each SME's business environment and their activities. For the empirical data, 497 samples were collected which, this sample data was extracted from the 'Korean Open Innovation Survey' performed by ETRI(Korean Electronics Telecommunications Research Institute) in 2010. As a result, empirical test results indicated that the impact of collaboration varies depend on the innovation types (Product and Process Innovation). The Impact of the collaboration level for the product innovation tend to be more effective when SMEs are developing for a final product, targeting on for individual customers (B2C). But on the other hand, the analysis result of the Process innovation tend to be higher than the product innovation, when SMEs are developing raw materials for their partners or to other firms targeting on for manufacturing industries(B2B). Also perceived importance of using external resources has effected to both product and process innovation performance. But Perceived importance of external partnership was statistically insignificant. Interesting finding was that the service product has negative effects on for the process innovation performance. And Relationship between size of the firms and their external collaboration activities with their performance of the innovations indicated that the bigger firms(over 100 of employees) tend to have better for both product and process innovations. Finally, implications of the results can be suggested as performance of innovation can be varied depends on firm's unique business idiosyncrasy as well as levels of external collaboration activities. The Implication of this research can be considered for firms in selecting an appropriate strategy as well as for policy makers.

Optical properties of $ZnIn_2Se$ and $ZnIn_2Se_4$:Co single crystals ($ZnIn_2Se_4$$ZnIn_2Se_4$:Co 단결정의 광학적 특성)

  • 최성휴;방태환;박복남
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.129-135
    • /
    • 1997
  • Undoped and Co-doped $ZnIn_2Se_4$ single crystals crystallized in the tetragonal space group 142m, with lattice constants a=5.748 $\AA$ and c=11.475 $\AA$, and a=5.567 $\AA$ and c=11.401 $\AA$. The optical absorption measured near the fundamental band edge showed that the optical energy band structure of these compounds had an indirect band gap, the direct and the indirect energy gaps of these compounds decreased as temperature changed from 10 to 300 K. The temperature coefficients of the direct energy gaps were found to be $\alpha=3.71\times10^{-4}$eV/K and $\beta$=519 K for $\alpha=3.71\times10^{-4}$eV/K and $\beta$=421K for $ZnIn_2Se_4$: Co. The temperature coefficients of the indirect energy gaps were also found to be $\alpha=2.31\times10^{-4}$ eV/K and $\beta$=285 K for $ZnIn_2Se_4$, and $\alpha=3.71\times10^{-4}$eV/K and $\beta$=609 K for $ZnIn_2Se_4$:Co, respectively. Six impurity optical absorption peaks due to cobalt are observed in $ZnIn_2Se_4$:Co single crystal. These impurity optical absorption peaks can be attibuted to the electronic transitions between the split energy levels of$CO^{2+}$ ions located at Td symmetry site of $ZnIn_2Se_4$ host lattice. The 1st order spin-orbit coupling constant ($\lambda$), Racah parameter (B), and crystal field parameter (Dq) ARE GIVEN AS -$243\textrm{cm}^{-1}, 587\textrm{cm}^{-1}, \;and\;327\textrm{cm}^{-1}$, respectively.

  • PDF

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

Design Evaluation Model Based on Consumer Values: Three-step Approach from Product Attributes, Perceived Attributes, to Consumer Values (소비자 가치기반 디자인 평가 모형: 제품 속성, 인지 속성, 소비자 가치의 3단계 접근)

  • Kim, Keon-Woo;Park, Do-Hyung
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.4
    • /
    • pp.57-76
    • /
    • 2017
  • Recently, consumer needs are diversifying as information technologies are evolving rapidly. A lot of IT devices such as smart phones and tablet PCs are launching following the trend of information technology. While IT devices focused on the technical advance and improvement a few years ago, the situation is changed now. There is no difference in functional aspects, so companies are trying to differentiate IT devices in terms of appearance design. Consumers also consider design as being a more important factor in the decision-making of smart phones. Smart phones have become a fashion items, revealing consumers' own characteristics and personality. As the design and appearance of the smartphone become important things, it is necessary to examine consumer values from the design and appearance of IT devices. Furthermore, it is crucial to clarify the mechanisms of consumers' design evaluation and develop the design evaluation model based on the mechanism. Since the influence of design gets continuously strong, various and many studies related to design were carried out. These studies can classify three main streams. The first stream focuses on the role of design from the perspective of marketing and communication. The second one is the studies to find out an effective and appealing design from the perspective of industrial design. The last one is to examine the consumer values created by a product design, which means consumers' perception or feeling when they look and feel it. These numerous studies somewhat have dealt with consumer values, but they do not include product attributes, or do not cover the whole process and mechanism from product attributes to consumer values. In this study, we try to develop the holistic design evaluation model based on consumer values based on three-step approach from product attributes, perceived attributes, to consumer values. Product attributes means the real and physical characteristics each smart phone has. They consist of bezel, length, width, thickness, weight and curvature. Perceived attributes are derived from consumers' perception on product attributes. We consider perceived size of device, perceived size of display, perceived thickness, perceived weight, perceived bezel (top - bottom / left - right side), perceived curvature of edge, perceived curvature of back side, gap of each part, perceived gloss and perceived screen ratio. They are factorized into six clusters named as 'Size,' 'Slimness,' 'No-Frame,' 'Roundness,' 'Screen Ratio,' and 'Looseness.' We conducted qualitative research to find out consumer values, which are categorized into two: look and feel values. We identified the values named as 'Silhouette,' 'Neatness,' 'Attractiveness,' 'Polishing,' 'Innovativeness,' 'Professionalism,' 'Intellectualness,' 'Individuality,' and 'Distinctiveness' in terms of look values. Also, we identifies 'Stability,' 'Comfortableness,' 'Grip,' 'Solidity,' 'Non-fragility,' and 'Smoothness' in terms of feel values. They are factorized into five key values: 'Sleek Value,' 'Professional Value,' 'Unique Value,' 'Comfortable Value,' and 'Solid Value.' Finally, we developed the holistic design evaluation model by analyzing each relationship from product attributes, perceived attributes, to consumer values. This study has several theoretical and practical contributions. First, we found consumer values in terms of design evaluation and implicit chain relationship from the objective and physical characteristics to the subjective and mental evaluation. That is, the model explains the mechanism of design evaluation in consumer minds. Second, we suggest a general design evaluation process from product attributes, perceived attributes to consumer values. It is an adaptable methodology not only smart phone but also other IT products. Practically, this model can support the decision-making when companies initiative new product development. It can help product designers focus on their capacities with limited resources. Moreover, if its model combined with machine learning collecting consumers' purchasing data, most preferred values, sales data, etc., it will be able to evolve intelligent design decision support system.

Error Analysis of Delivered Dose Reconstruction Using Cone-beam CT and MLC Log Data (콘빔 CT 및 MLC 로그데이터를 이용한 전달 선량 재구성 시 오차 분석)

  • Cheong, Kwang-Ho;Park, So-Ah;Kang, Sei-Kwon;Hwang, Tae-Jin;Lee, Me-Yeon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.332-339
    • /
    • 2010
  • We aimed to setup an adaptive radiation therapy platform using cone-beam CT (CBCT) and multileaf collimator (MLC) log data and also intended to analyze a trend of dose calculation errors during the procedure based on a phantom study. We took CT and CBCT images of Catphan-600 (The Phantom Laboratory, USA) phantom, and made a simple step-and-shoot intensity-modulated radiation therapy (IMRT) plan based on the CT. Original plan doses were recalculated based on the CT ($CT_{plan}$) and the CBCT ($CBCT_{plan}$). Delivered monitor unit weights and leaves-positions during beam delivery for each MLC segment were extracted from the MLC log data then we reconstructed delivered doses based on the CT ($CT_{recon}$) and CBCT ($CBCT_{recon}$) respectively using the extracted information. Dose calculation errors were evaluated by two-dimensional dose discrepancies ($CT_{plan}$ was the benchmark), gamma index and dose-volume histograms (DVHs). From the dose differences and DVHs, it was estimated that the delivered dose was slightly greater than the planned dose; however, it was insignificant. Gamma index result showed that dose calculation error on CBCT using planned or reconstructed data were relatively greater than CT based calculation. In addition, there were significant discrepancies on the edge of each beam while those were less than errors due to inconsistency of CT and CBCT. $CBCT_{recon}$ showed coupled effects of above two kinds of errors; however, total error was decreased even though overall uncertainty for the evaluation of delivered dose on the CBCT was increased. Therefore, it is necessary to evaluate dose calculation errors separately as a setup error, dose calculation error due to CBCT image quality and reconstructed dose error which is actually what we want to know.

A STUDY OF INTRAORAL ANATOMIC LANDMARKS OF KOREAN ADULT-UPPER JAW (성인 유치악자 상악골의 악궁과 치열궁의 형태에 관한 조사)

  • Oh, Yu-Ree;Lee, Sung-Bok;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.753-768
    • /
    • 1995
  • For accurate impression taking of dental patient and esthetic denture treatment of ednetulous patient, measuring between intraoral anatomic landmarks is useful.In this study the subjects selected at a random were two-jundred forty persons with a mean age 22.5(range 21-24) and were taken impression of by irreversible hydrocolloid impression material(Alginate). On the study model made by dental stone, each individual tray was made and final impresion was taken by border moilding. On final model measurings were performed with 3-dimensional measuring device and the values were analyzed by t-test The results is following : ABOUT THE MEASURED VALUES. 1. The width between maxillary right and left canine cusp tip was average 36.44mm(s.d. 2.48), man 36.67mm, woman 35.83mm(p<0.05). 2. The width between labial height of contour of maxillary right and left canine was average 40.08mm(s.d. 2.42), man 40.29mm, woman 39.52mm(p<0.05). 3. The width between mesio-lingual cusps of maxillary first molar was average 43.14mm(s.d. 3.33), man 43.56mm, woman 42.05mm(p<0.05). 4. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary first molar was average 64.89mm(s.d. 3.88), man 65.58mm, woman 62.92mm(p<0.05). 5. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary second molar was average 68.58mm(s.d. 3.91), man 69.29mm, woman 66.30mm (p<0.05). 6. The width between right and left hamular notch was average 49.80mm(s.d. 3.96), man 50.70mm, woman 48.20mm(p<0.05). 7. The length from labial heigth of contour of maxillary central incisor to center of incisive papilla was average 9.52mm(s.d. 1.18), man 9.46mm, woman 9.63mm(p>0.05). 8. The length from labial heigth of contour of maxillary central incisor to palatine fovea was average 53.27mm(s.d. 2.93), man 53.93mm, woman 52.08mm(p<0.05). 9. The center of incisive papilla ws located posterior to intercanine line at 0.40mm(s.d. 1.16), man 0.51mm, woman 0.11mm(p<0.05). 10. The height from incisal edge of maxillary central incisor to the labial vestibule was average 21.84mm(s.d. 1.38), man 22.01mm, woman 21.00mm(p<0.05). 11. The height from mesiolingual cusp of maxillary first molar to buccalvestible was average 17.45mm(s.d. 1.42), man 17.56mm, woman 17.08mm(p>0.05). 12. The height from hamular notch to standard occlusal plane was average 6.84mm(s.d. 1.06), man 6.91mm, woman 6.70mm(p>0.05). 13. The height from the deepest point of palatal vault to standard occlsalplane was average 19.95 mm(s.d. 2.03), man 20.19mm, woman 19.12mm(p<0.05). ABOUT THE ARCH FORM 1. The arch form was able to classify into four typr by the rate of the measured values. Each arch form distribution was that the 1 group had 32.46% the 2 group 2.19%, the 3 group 52.83%, the 4 group 12.72%. The sexual composition was that in 1 group man had 73.5%, woman 26.5%, in 2 group man had 40.0%, woman 60.0%, in 3 group man had 83.3%, woman 16.7%, and in 4 group man had 55.17%, woman 44.83%. 2. When canine cusp tip was marked as point O, the intersection point between labial height of contour of maxillary central incisor and intermaxillary suture as point A, height of contour of maxillary second molar buccal alveolar ridge as B point, ${\angle}$AOB was measured $133.8^{\circ}$for the 1 group, $133.0^{\circ}$for the 2 group, $132.3^{\circ}$for the 3 group, $128.9^{\circ}$for the 4 group.

  • PDF