• 제목/요약/키워드: ECG parameters

검색결과 138건 처리시간 0.022초

Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering

  • Goo, Hyun Woo
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1031-1041
    • /
    • 2018
  • Objective: To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. Materials and Methods: Eighty-six children (${\leq}3$ years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. Results: There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 ($1.13{\pm}0.09mGy$) and group 2 ($1.07{\pm}0.12mGy$, p < 0.02). Among image quality parameters, significantly higher image noise ($3.8{\pm}0.7$ Hounsfield units [HU] vs. $3.3{\pm}0.6HU$, p < 0.001), significantly lower signal-to-noise ratio ($105.0{\pm}28.9$ vs. $134.1{\pm}44.4$, p = 0.001) and contrast-to-noise ratio ($84.5{\pm}27.2$ vs. $110.1{\pm}43.2$, p = 0.002), and significantly less diaphragm motion artifacts ($3.8{\pm}0.5$ vs. $3.7{\pm}0.4$, p < 0.04) were found in group 1 compared with group 2. Image quality grades of cardiac structures, coronary arteries, ascending aorta, pulmonary trunk, lung markings, and chest wall showed no significant difference between groups (p > 0.05). Conclusion: In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.

새로운 비관혈적 태아 저산소증 진단 방법개발에 관한 연구 (Development of a New Non-invasive Fetal Hypoxia Diagnosis System)

  • 이전;이경중
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권11호
    • /
    • pp.495-501
    • /
    • 2006
  • Diagnostics of unborn baby is mainly aimed at prediction and detection of occurrence of intrauterine hypoxia. Consequences resulting from fetal hypoxia appear in its heart activity. In this study, we have developed a new non-invasive system for fetal hypoxia diagnosis which provides systolic time interval(STI) parameters on the basis of analysis of electrical and mechanical heart activity together. For this we have worked on 1) the proper lead system for the acquisition of abdominal ECG, 2) the independent component analysis based signal processing and fetal ECG separation, 3) the development of a hardware which consists of an abdominal ECG amplifying module and an ultrasound module and 4) the detection of characteristic points of FECG and Doppler signal and the extraction of diagnostic parameters. The developed system was evaluated by the clinical experiments in which 33 subjects were participated. The acquired STI by the system were distributed within the ranges from the well-established invasive results of other researchers. From this, we can conclude that the developed non-invasive fetal hypoxia diagnosis system is useful.

휴대용 Intelligent QT 분석기의 개발에 관한 연구 (A Study on the Development of the Portable Intelligent QT Analyzer)

  • 이경중;민혜정
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.57-64
    • /
    • 1990
  • This study describes the design of the portable intelligent QT analyzer which can record and analyze the ambulatory ECG data. System hardware is consisted of the one chip microcomputer(80C31) , A/D, ROM, RAM, LCD display and preamplifier. ECG data were processed by the differentiator and the digital filter. The de- tection of the parameters-QT, QTP and RR interval-was accomplished by the software algorithm using the slope and the amplitude of the processed data. Using this system, the trends of the parameters obtained during the long term could be observed.

  • PDF

조명의 색온도에 따른 작업자의 피로도 평가 (1) - 주관평가와 ECG 파라미터의 상관관계분석 - (Evaluation of Fatigue by Lighting color temperature (1) - Analysis of relation between subjective rating score and ECG parameters-)

  • 임석기;고한우;양희경;윤용현;김묘향
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 춘계학술대회 논문집
    • /
    • pp.186-189
    • /
    • 2001
  • 본 연구에서는 2종류의 색온도(4000 K, 2700 K)조건 하에서 작업자의 피로도를 평가하기 위하여 피험자에게 검색작업을 부가하고 주관평가 및 생리신호를 측정하였다. 주관평가는 ME(Magnitude Estimation)법의 설문지를 사용했으며, 생리신호는 ECG, 맥파, 피부전도도, 피부온도, 호흡, 뇌파를 측정하여 그중 ECG신호를 분석하였다. ECG신호 파라미터로서 IBI, BPM, 평균 BPM, LF/HF, CSI, CVI, CV-RR를 분석한 결과, 특히 CSI, CVI, CV-RR가 피로도와 상관관계가 높았다.

  • PDF

시-주파수 분석을 이용한 심실세동시 심전도 분석을 통한 제세동 예측에 관한 연구 (Prediction of Defibrillation Success of Ventricular Fibrillation ECG Signals using Time-Frequency Analysis)

  • 성홍모;신재우;이현숙;황성오;윤영로
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권4호
    • /
    • pp.181-188
    • /
    • 2006
  • The purpose of this study is to predict the defibrillation success of a ventricular Fibrillation ECG signal using time-frequency analysis. During CPR, coronary perfusion pressure and electrocardiogram were measured. Parameters extracted from time-frequency domain were served as predictor of resuscitation success. Time frequency distribution(TFD) of ECG signals was estimated from the smoothed pseudo Wigner-Ville distribution(SPWVD). Median frequency, peak frequency, 1/f slope, frequency band ratios$(2{\sim}4Hz,\;4{\sim}6Hz,\;6{\sim}8Hz,\;8{\sim}10Hz,\;10{\sim}12Hz,\;12{\sim}15Hz)$ were extracted from each TFD as function of time. Paired t-test was used to determine the differences in ROSC and non-ROSC groups. In the statistical results, we selected four significant parameters - median frequency, 1/f slope, $2{\sim}4Hz$ band ratio, $8{\sim}10Hz$ band ratio. We made an attempt to predict defibrillation success by combining features extracted from time frequency distribution. Independent t-test was used to determine the differences ROSC and non-ROSC groups. Consequently, we selected four significant parameters-median frequency, 1/f slope, $2{\sim}4Hz$ band ratio, $8{\sim}10Hz$ band ratio. The relationship between coronary perfusion pressure and ECG parameters was analyzed with linear regression analysis. R-square value was 55%. 1/f slope and $8{\sim}10Hz$ band ratio had the significant relationship with coronary perfusion pressure.

무구속적 방법으로 측정된 심전도의 신뢰도 판별 (Quality Level Classification of ECG Measured using Non-Constraint Approach)

  • 김윤재;허정;박광석;김성완
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.161-167
    • /
    • 2016
  • Recent technological advances in sensor fabrication and bio-signal processing enabled non-constraint and non-intrusive measurement of human bio-signals. Especially, non-constraint measurement of ECG makes it available to estimate various human health parameters such as heart rate. Additionally, non-constraint ECG measurement of wheelchair user provides real-time health parameter information for emergency response. For accurate emergency response with low false alarm rate, it is necessary to discriminate quality levels of ECG measured using non-constraint approach. Health parameters acquired from low quality ECG results in inaccurate information. Thus, in this study, a machine learning based approach for three-class classification of ECG quality level is suggested. Three sensors are embedded in the back seat, chest belt, and handle of automatic wheelchair. For the two sensors embedded in back seat and chest belt, capacitively coupled electrodes were used. The accuracy of quality level classification was estimated using Monte Carlo cross validation. The proposed approach demonstrated accuracy of 94.01%, 95.57%, and 96.94% for each channel of three sensors. Furthermore, the implemented algorithm enables classification of user posture by detection of contacted electrodes. The accuracy for posture estimation was 94.57%. The proposed algorithm will contribute to non-constraint and robust estimation of health parameter of wheelchair users.

ECG 특징추출을 위한 하드웨어시스템의 설계 (Design of a hardware system for ECG feature extraction)

  • 이경중;윤형로;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.697-700
    • /
    • 1988
  • This paper describes the design of a hardware system for ECG feature extraction based on pipeline processor consisting of three computers. ECG data is acquisited by 12 bit A/D converter with hardware QRS triggred detector. Four diagnostic parameters-heart, axis, and ST axis, and ST segment are used for the classification and the diagnosis of arrhythmia. The functions of the main CPU were distributed and processed with three microcomputers. Therefore the effective data process and the real time process using microcomputer can be obtained. The interconnection structure consisting of two common memory units is designed to decrease the delay time caused by data transfer between processors and designed by which the delay time can be taken 1% of one clock period.

  • PDF

웨이브렛 변환과 적응 프랙탈 보간을 이용한 심전도 데이터 압축 (ECG data compression using wavelet transform and adaptive fractal interpolation)

  • 윤영노;이우희
    • 전자공학회논문지B
    • /
    • 제33B권12호
    • /
    • pp.45-61
    • /
    • 1996
  • This paper presents the ECG data compression using wavelet transform (WT) and adaptive fractal interpolation (AFI). The WT has the subband coding scheme. The fractal compression method represents any range of ECG signal by fractal interpolation parameters. Specially, the AFI used the adaptive range sizes and got good performance for ECG data cmpression. In this algorithm, the AFI is applied into the low frequency part of WT. The MIT/BIH arhythmia data was used for evaluation. The compression rate using WT and AFI algorithm is better than the compression rate using AFI. The WT and AFI algorithm yields compression ratio as high as 21.0 wihtout any entropy coding.

  • PDF

ECG-NIBP 환자감시장치 개발 (Development of ECG-NIBP Patient Monitoring System)

  • 김남현;심원흠;이건기;라상원;김경하
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.315-318
    • /
    • 1997
  • The ECG-NIBP patient monitor consist of Noninvasive Blood Pressure(NIBP) module that have micro controller inside. This module transfer data by serial communication to the main processor. This system apply the fuzzy inflating method to reduce the blood pressure measuring time, and moving artifact removing algorithm, several parameters used or more accurate measurement. The ECG monitor use the Digital Signal Processor(DSP) or digital filtering, peak detection, heart rate calculation. This system also offer convenient user interface by rotary key, menu bar. With 7" CRT display, auxiliary TFT LCD display adapted to display information on wide screen.

  • PDF

웨이브렛 변환과 적응 프랙탈 보간을 이용한 심전도 데이터 압축 (ECG Data Compression Using Wavelet Transform and Adaptive Fractal Interpolation)

  • 이우희;윤영로;박세진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.221-224
    • /
    • 1996
  • This paper presents the ECG data compression using wavelet transform(WT) and adaptive fractal interpolation(AFI). The WT has the subband coding scheme. The fractal compression method represents any range of ECG signal by fractal interpolation parameters. Specially, the AFI used the adaptive range sizes and got good performance for ECG data compression. In this algorithm, the AFI is applied into the low frequency part of WT. The MIT/BIH arrhythmia data was used for evaluation. The compression rate using WT and AFI algorithm is better than the compression rate using AFI. The WT and AFI algorithm yields compression ratio as high as 21.0 without any entroy coding.

  • PDF