• Title/Summary/Keyword: ECG monitoring system

Search Result 187, Processing Time 0.026 seconds

Wireless Three-Pad ECG System: Challenges, Design, and Evaluations

  • Cao, Huasong;Li, Haoming;Stocco, Leo;Leung, Victor C.M.
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.113-124
    • /
    • 2011
  • Electrocardiography (ECG) is a widely accepted approach for monitoring of cardiac activity and clinical diagnosis of heart diseases. Since cardiologists have been well-trained to accept 12-lead ECG information, a huge number of ECG systems are using such number of electrodes and placement configuration to facilitate fast interpretation. Our goal is to design a wireless ECG system which renders conventional 12-lead ECG information.We propose the three-pad ECG system (W3ECG). W3ECG furthers the pad design idea of the single-pad approach. Signals obtained from these three pads, plus their placement information, make it possible to synthesize conventional 12-lead ECG signals.We provide one example of pad placement and evaluate its performance by examining ECG data of four patients available from online database. Feasibility test of our selected pad placement positions show comparable results with respect to the EASI lead system. Experimental results also exhibit high correlations between synthesized and directly observed 12-lead signals (9 out of 12 cross-correlation coefficients higher than 0.75).

Zigbee based 1-ch ECG device with activity monitoring function (지그비를 기반으로 한 운동감시 기능을 가진 1채널 ECG장치 개발)

  • Hong, Joo-Hyun;Kim, Nam-Jin;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.41-43
    • /
    • 2005
  • PDA-based monitoring is used to acquire continuously the patient's vital signs, including electrocardiography, activity, heart rate and $SpO_2$. In this paper, A biomedical signal acquisition device was designed using 3-axial MEMS accelerometer and 1-ch ECG amplifier, to have the function of monitoring activity and electrocardiography. The proposed system is composed of transmitter and receiver. Through the Zigbee communication, subject's biosignals can be transmitted in real-time to receiver, and transmitted data confirmed using PDA. The packet size used in this device was set not to exceed a maximum payload size of 116 byte. One packet consists of two segments. The transmission speed was 21 packet per second, 420 ECG samples per second, and 42 acceleration samples per second. The proposed method can be used to develop Activities of Daily Living(ADL} monitoring devices for the elderly or movement impaired people and enables patients to be monitored without any constraints. Also, this method will reduce medical costs in the aged society.

  • PDF

A Study on the Implementation of Ambulatory Monitoring System Using Wireless Data Communication Network (무선 데이터 통신망을 이용한 보행형 감시 시스템 개발에 관한 연구)

  • Go, Seong-Il;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.75-80
    • /
    • 1999
  • Since a Holter monitor records a patients' ECG when he is in motion, it can monitor complex heart disease effectively. But it can not handle a sudden heart disease because the diagnosis process will be done only after 24 hours. So in this study, a model of ambulatory monitoring system using wireless data communication network is proposed. And a mobile ECG equipment and a doctors' terminal are developed for the proposed system implementation. As a result, we can evaluate that the proposed ambulatory monitoring system is suitable for the management of ambulatory patients who may be at risk form sudden cardiac abnormalities.

  • PDF

A compact and low-power consumable device for continuous monitoring of biosignal (소형화 및 저전력소모를 구현한 실시간 생체신호 측정기 개발)

  • Cho, Jung-Hyun;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.334-340
    • /
    • 2006
  • A compact biosignal monitoring device was developed. Electrodes for electrocardiogram (ECG) and a LED and silicon detector for photoplethysmogram (PPG) were used. A lead II type was arranged for ECG measurement and reflected light was measured at the finger tip for PPG. A single chip microprocessor (model ADuC812, Analog Device) controlled a measurement protocol and processed measured signals. PPG and ECG had a sampling rate of 300 Hz with 8-bit resolution. The maximum power consumption was 100 mW. The microprocessor computed pulse transit time (PTT) between the R-wave of ECG and the peak of PPG. To increase the resolution of PTT, analog peak detectors obtained the peaks of ECG and PPG whose interval was calculated using an internal clock cycle of 921.6 kHz. The device was designed to be operated by 3-volt battery. Biosignals can be measured for $2{\sim}3$ days continuously without the external interruptions and data is stored to an on-board memory. Our system was successfully tested with human subjects.

A Cell Phone-based ECG, Blood Pressure Monitoring System for Personal Healthcare Applications using Wireless Sensor Network Technology

  • Toh, Sing-Hui;Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.505-508
    • /
    • 2008
  • Electrocardiogram (ECG) and blood pressure (BP) are main vital signs which are the standards in most medical settings in assessing the most basic body functions. Multi parameters are desired in providing more information for health professionals in order to detect or monitor medical problems of patients more precisely. This study urges us to develop a robust wireless healthcare monitoring system which has multiple physiological signs measurements on real time that applicable to various environments which integrates wireless sensor network technology and code division multiple access (CDMA) network with extended feature of locally standalone diagnosis algorithms that implemented in tell phone. ECG signal and BP parameter of the patients are routinely be monitored, processed and analyzed in details at cell phone locally to produce useful medical information to ease patients for tracking and future reference purposes. Any suspected or unknown patterns of signals will be immediately forwarded to hospital server using cell phone for doctors' evaluation. This feature enables the patients always recognize the importance of self-health checking so that the preventive actions can be taken earlier through this analytic information provided by this monitoring system because "Prevention is better than Cure".

  • PDF

Power Efficient Classification Method for Sensor Nodes in BSN Based ECG Monitoring System

  • Zeng, Min;Lee, Jeong-A
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9B
    • /
    • pp.1322-1329
    • /
    • 2010
  • As body sensor network (BSN) research becomes mature, the need for managing power consumption of sensor nodes has become evident since most of the applications are designed for continuous monitoring. Real time Electrocardiograph (ECG) analysis on sensor nodes is proposed as an optimal choice for saving power consumption by reducing data transmission overhead. Smart sensor nodes with the ability to categorize lately detected ECG cycles communicate with base station only when ECG cycles are classified as abnormal. In this paper, ECG classification algorithms are described, which categorize detected ECG cycles as normal or abnormal, or even more specific cardiac diseases. Our Euclidean distance (ED) based classification method is validated to be most power efficient and very accurate in determining normal or abnormal ECG cycles. A close comparison of power efficiency and classification accuracy between our ED classification algorithm and generalized linear model (GLM) based classification algorithm is provided. Through experiments we show that, CPU cycle power consumption of ED based classification algorithm can be reduced by 31.21% and overall power consumption can be reduced by 13.63% at most when compared with GLM based method. The accuracy of detecting NSR, APC, PVC, SVT, VT, and VF using GLM based method range from 55% to 99% meanwhile, we show that the accuracy of detecting normal and abnormal ECG cycles using our ED based method is higher than 86%.

Real -Time ECG Signal Acquisition and Processing Using LabVIEW

  • Sharma, Akshay Kumar;Kim, Kyung Ki
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.162-171
    • /
    • 2020
  • The incidences of cardiovascular diseases are rapidly increasing worldwide. The electrocardiogram (ECG) is a test to detect and monitor heart issues via electric signals in the heart. Presently, detecting heart disease in real time is not only possible but also easy using the myDAQ data acquisition device and LabVIEW. Hence, this paper proposes a system that can acquire ECG signals in real time, as well as detect heart abnormalities, and through light-emitting diodes (LEDs) it can simultaneously reveal whether a particular waveform is in range or otherwise. The main hardware components used in the system are the myDAQ device, Vernier adapter, and ECG sensor, which are connected to ECG monitoring electrodes for data acquisition from the human body, while further processing is accomplished using the LabVIEW software. In the Results section, the proposed system is compared with some other studies based on the features detected. This system is tested on 10 randomly selected people, and the results are presented in the Simulation Results section.

The R-R interval detection system for ECG analysis (ECG 분석을 위한 R-R interval 탐지 시스템)

  • Kim, Young-Seop;Hong, Sung-Ho;Chi, Yong-Seok;Lee, Myeong-Seok;Noh, Hack-Youp
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.11 no.2
    • /
    • pp.29-33
    • /
    • 2012
  • ECG widely used in cardiac function test is a graph that is recorded by measuring the electrical impulses occurred in the heart. Normal ECG has the form of similar sections that are repeated, and each section has the information occurred in a heart beat. Thus, In order to make the correct diagnosis, correct grasp of the sections and formed analysis must be done. In this research, a system that detects the sections of ECG is proposed. The system is based on ECG stored in the form of files. The ECG can easily have a noise caused by an outside factor. The noise of ECG is easily caused by external factors. Through a band-pass filter, it can be removed. and then, to get this ECG without a noise, interval detection algorithm using R-peak is applied. The clean, intuitive interface will help the above functions to be used without any difficulties.

  • PDF

A Research for Removing ECG Noise and Transmitting 1-channel of 3-axis Accelerometer Signal in Wearable Sensor Node Based on WSN (무선센서네트워크 기반의 웨어러블 센서노드에서 3축 가속도 신호의 단채널 전송과 심전도 노이즈 제거에 대한 연구)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.137-144
    • /
    • 2011
  • Wireless sensor network(WSN) has the potential to greatly effect many aspects of u-healthcare. By outfitting the potential with WSN, wearable sensor node can collects real-time data on physiological status and transmits through base station to server PC. However, there is a significant gap between WSN and healthcare. WSN has the limited resource about computing capability and data transmission according to bio-sensor sampling rates and channels to apply healthcare system. If a wearable node transmits ECG and accelerometer data of 4 channel sampled at 100 Hz, these data may occur high loss packets for transmitting human activity and ECG to server PC. Therefore current wearable sensor nodes have to solve above mentioned problems to be suited for u-healthcare system. Most WSN based activity and ECG monitoring system have been implemented some algorithms which are applied for signal vector magnitude(SVM) algorithm and ECG noise algorithm in server PC. In this paper, A wearable sensor node using integrated ECG and 3-axial accelerometer based on wireless sensor network is designed and developed. It can form multi-hop network with relay nodes to extend network range in WSN. Our wearable nodes can transmit 1-channel activity data processed activity classification data vector using SVM algorithm to 3-channel accelerometer data. ECG signals are contaminated with high frequency noise such as power line interference and muscle artifact. Our wearable sensor nodes can remove high frequency noise to clear original ECG signal for healthcare monitoring.

A Study of Electrode Locations for Design of ECG Monitoring Smart Clothing based on Body Mapping (심전도 모니터링 스마트 의류 디자인을 위한 바디매핑 기반 전극 위치 연구)

  • Cho, Hakyung;Cho, Sang woo
    • Fashion & Textile Research Journal
    • /
    • v.17 no.6
    • /
    • pp.1039-1049
    • /
    • 2015
  • The increase in the need for a 24 hour monitoring of biological signals has been accompanied by an increasing interest in wearable systems that can register ECG at any time and place. ECG-monitoring clothing is a wearable system that records heart function continuously, but there have been difficulties in making accurate measurements due to motion artifacts. Although various factors may cause noise in measurements due to motion, the variations in the body surface and clothing during movements that cause eventual the shifting and displacement of the electrodes is particularly noteworthy. Therefore, this study used biomedical body mapping and a motion-capture system to measure and analyze the changes in the body surface and garment during movements. It was deduced that the area where the friction and separation between the garment and skin is the lowest would be the appropriate location to place the ECG electrodes. For this study, 5 male and 5 female in their 20s were selected as subjects, and through their selected body movements, the changes in the garment and skin were analyzed using the motion-capture system. As a result, the area below the chest circumference and the area below the shoulder blades were proposed as the optimal location of electrode for ECG monitoring.