• 제목/요약/키워드: E-TAP

검색결과 160건 처리시간 0.03초

Effect of intracanal medications on the interfacial properties of reparative cements

  • Pereira, Andrea Cardoso;Pallone, Mariana Valerio;Marciano, Marina Angelica;Cortellazzi, Karine Laura;Frozoni, Marcos;Gomes, Brenda P.F.A.;de Almeida, Jose Flavio Affonso;de Jesus Soares, Adriana
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.21.1-21.8
    • /
    • 2019
  • Objectives: The purpose of the present study was to evaluate the effect of calcium hydroxide with 2% chlorhexidine gel (HCX) or distilled water (HCA) compared to triple antibiotic paste (TAP) on push-out bond strength and the cement/dentin interface in canals sealed with White MTA Angelus (WMTA) or Biodentine (BD). Materials and Methods: A total of 70 extracted human lower premolars were endodontically prepared and randomly divided into 4 groups according to the intracanal medication, as follows: group 1, HCX; group 2, TAP; group 3, HCA; and group 4, control (without intracanal medication). After 7 days, the medications were removed and the cervical third of the specimens was sectioned into five 1-mm sections. The sections were then sealed with WMTA or BD as a reparative material. After 7 days in 100% humidity, a push-out bond strength test was performed. Elemental analysis was performed at the interface, using energy-dispersive spectroscopy. The data were statistically analyzed using analysis of variance and the Tukey test (p < 0.05). Results: BD presented a higher bond strength than WMTA (p < 0.05). BD or WMTA in canals treated with calcium hydroxide intracanal medications had the highest bond strength values, with a statistically significant difference compared to TAP in the WMTA group (p < 0.05). There were small amounts of phosphorus in samples exposed to triple antibiotic paste, regardless of the coronal sealing. Conclusions: The use of intracanal medications did not affect the bond strength of WMTA and BD, except when TAP was used with WMTA.

초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구 (Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier)

  • 김성아;김지현;이민주;김자연;정우식;박준홍
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.227-235
    • /
    • 2021
  • This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

심근보호에 대한 임상적 고찰 (Clinical study of myocardial preservation)

  • 조재일;이영균
    • Journal of Chest Surgery
    • /
    • 제17권4호
    • /
    • pp.557-564
    • /
    • 1984
  • Of the valve replacement patients operated between 1983 and June, 1984, 75 patients need more than 60 minutes of aortic cross-clamping time. 42 patients performed single valve replacement [35 MVR, 7 AVR with or without TAP] and remainder needs double valve replacement with or without TAP. The average aortic clamping time was 95.1 minutes. They need 30 minutes more extra-corporeal circulation time than aortic clamping time. The patients were divided into two groups by usage of cardioplegic solution. Group I [n=31] with Bretschneider solution and group II with potassium cardioplegic solution [M.G.H. modification] were analyzed by extra-corporeal circulation data,/CG and Echocardiography findings, and clinical data. There was no difference between two groups in Bivon addition amounts [cc/kg] and E.F. and S.F. by echocardiography, group I need 1 more electrocardioversion to convert sinus rhythm postoperatively. Also no difference could be found in patients whose preoperative C.I. was above 2.0 between two group. But significant postoperative decrease in E.F. was found in group I whose preoperative C.I. was below 2.0. Relatively longer ECC time was also needed in same group. Ischemic changes in ECG and low cardiac output syndrome was, however more prevalent in groupII. As a whole, the clinical data was satisfactory with both cardioplegic solution in clinical practice.

  • PDF

전자혀 및 다변량 분석법을 활용한 먹는물의 구별 방법 (Discrimination of the drinking water taste by potentiometric electronic tongue and multivariate analysis)

  • 김은주;황태문;구재욱;송재용;박홍경;남숙현
    • 상하수도학회지
    • /
    • 제37권6호
    • /
    • pp.425-435
    • /
    • 2023
  • Organoleptic parameters such as color, odor, and flavor influence consumer perception of drinking water quality. This study aims to evaluate the taste of the selected bottled and tap water samples using an electronic tongue (E-tongue) instead of a sensory test. Bottled and tap water's mineral components are related to the overall preference for water taste. Contrary to the sensory test, the potentiometric E-tongue method presented in this study distinguishes taste by measuring the mineral components in water, and the data obtained can be statistically analyzed. Eleven bottled water products from various brands and one tap water from I city in Korea were evaluated. The E-tongue data were statistically analyzed using multivariate statistical tools such as hierarchical clustering analysis (HCA), principal component analysis (PCA), and partial least squares discriminant analysis (PLS-DA). The results show that the E-tongue method can clearly distinguish taste discrimination in drinking water differing in water quality based on the ion-related water quality parameters. The water quality parameters that affect taste discrimination were found to be total dissolved solids (TDS), sodium (Na+), calcium (Ca2+), magnesium (Mg2+), sulfate (SO42-), chloride (Cl-), potassium (K+) and pH. The distance calculation of HCA was used to quantify the differences between 12 different types of drinking water. The proposed E-tongue method is a practical tool to quantitatively evaluate the differences between samples in water quality items related to the ionic components. It can be helpful in quality control of drinking water.

5-Tap Adaptive PRML Architecture for High-Density Optical Disc Channel

  • Choi, Goang-Seog
    • 한국멀티미디어학회논문지
    • /
    • 제10권12호
    • /
    • pp.1585-1590
    • /
    • 2007
  • This paper introduces adaptive PRML (Partial Response Maximum Likelihood) architecture with PR (a,b,c,d,e) channel type for the improved readability of high-density optical discs with capacity greater than 30GB. The proposed PRML architecture consists of an adaptive equalizer, a Viterbi detector and a channel identifier. Detailed description for each component is included. The architecture is implemented in chip and also confirmed its performance on the test board mounting the chip. Test results show that the proposed 5-tap PRML architecture is well operated, and less than $2{\times}10^{-4}$ of BER (Bit Error Rate) is achieved with radial and tangential tilt margin of ${\pm}0.6^{\circ}$ on self-made 30GB BD at 1x speed.

  • PDF

광반응기와 Euglena gracilis Z를 이용한 이산화탄소 고정화 공정의 거동 특성 (The Behavior of a $CO_2$Fixation Process by Euglena Gracilis Z with a Photobioreactor)

  • 신항식;채소용;황응주;임재림;남세용
    • KSBB Journal
    • /
    • 제15권6호
    • /
    • pp.644-648
    • /
    • 2000
  • Biological fixation of carbon dioxide using microalgae is known as an effective CO$_2$reduction technology. However, many environmental factors influence microalgal productivity. Optimal cultivation factors were determined for the green alga, Euglena gracilis Z, which offers high protein and vitamin E content for animal fodder. In batch culture in a photovioreactor, it was found that theinitial pH, temperature, CO$_2$concentration in air, and light intensity during the optimal cultivating conditions were 3.5, 27$^{\circ}C$, 5-10% and 520 ${\mu}$mol/㎡/s, respectively. When tap water and freshwater were used as cultivating media unsterilized tap water was found to be effective. A kinetic model was considered to determine the relationship between the specific growth rate and the light intensity. The half-velocity coefficient (K(sub)I) in the Monod model under photoautotrophic conditions was 978.9 ${\mu}$mol/㎡/s.

  • PDF

수돗물 부식성 제어를 통한 수도관 부식방지기술: 석회수 분산화장치를 이용한 미네랄 공급 효과와 영향 분석 (Corrosion control technology in water pipes by adjusting the corrosivity of drinking water : effect and impact of the lime dispersion system)

  • 한금석;박영복;김성재;김현돈;최영준;박주현;우달식;홍성호
    • 상하수도학회지
    • /
    • 제32권3호
    • /
    • pp.235-242
    • /
    • 2018
  • Corrosion inhibitors including calcium hydroxide have been used to prevent corrosion in the pipes for tap water supply. The corrosion index (i.e., Langelier Index) differs by area and water quality. The corrosion indices of the areas studied differed by more than 2.0. The 'homogenized' calcium hydroxide was added to the treated water at the K water treatment plant, in order to increase the value of the corrosion index and the concentration of calcium. As the result, the concentration of calcium was increased while the turbidity and pH changed little. The corrosion rate of the tap water with the 'homogenized' calcium hydroxide could be slowed down pretty much. The results suggested that the technology of 'homogenization' of calcium hydroxide can applied to tap water and desalinated water to prevent corrosion in water pipes even in corrosive pipes.

공공청사의 운영비용에 영향을 미치는 요인과 요인별 영향력 분석 (Analysis of Factors and it's Effectiveness to Maintenance Cost of Public Buildings)

  • 고규진;조상욱;황정하;이찬식
    • 한국건설관리학회논문집
    • /
    • 제16권2호
    • /
    • pp.29-37
    • /
    • 2015
  • 공동주택은 장기수선충당금제도 등에 따라 중 장기적인 관점에서 효율적인 유지관리가 수행되고 있는 반면, 공공청사는 과거 유지관리비 실적자료 부족과 비효율적인 예산산정 등의 문제로 인해 유지관리가 체계적으로 이루어지지 않고 있다. 본 연구에서는 인천지역의 공공청사를 대상으로 운영비의 영향요인을 분석하고, 이를 검증하기 위해 상관관계 분석 및 다중회귀 분석을 실시하였다. 공공청사의 전기, 가스, 수도요금에 대한 경과년수, 연면적, 직원 수의 영향력을 분석한 결과, 전기요금은 직원 수와 높은 상관성을 보였으며 가스, 수도요금은 연면적과 상관성이 있는 것으로 나타났다. 다중회귀 분석을 통해 상관관계 분석결과를 검증하였으며, 회귀 방정식을 통해 운영비용의 추정모형을 제시하였다.

전압 불안정시 PSS/E 사용자 정의모델로 구현된 거리계전기 응동 특성 (Operating Characteristic of a User Defined Distance Relay Model in PSS/E during Voltage Instability)

  • 이동규;강상희;양정재;오화진;장병태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.82-84
    • /
    • 2003
  • This paper presented a method to develop a relay model by the user-written model function of PSS/E. As for the voltage instability, although generator current limiters, transformer's tap-changers and dynamic loads have been considered as the dominant components, the protection system is also very important because it may influence the system's dynamic behaviour. Hence a distance relay model implemented with the suggested method was added, and then the operating characteristics of the distance relay under the voltage instability condition were investigated.

  • PDF

Performance Evaluation and Convergence Analysis of a VEDNSS LMS Adaptive Filter Algorithm

  • Park, Chee-Hyun;Hong, Kwang-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • 제27권2E호
    • /
    • pp.64-68
    • /
    • 2008
  • This paper investigates noise reduction performance and performs convergence analysis of a Variable Error Data Normalized Step-Size Least Mean Square(VEDNSS LMS) algorithm. Adopting VEDNSS LMS results in higher system complexity, but noise is reduced providing fast convergence speed Mathematical analysis demonstrates that tap coefficient misadjustment converges. This is confirmed by computer simulation with the proposed algorithm.