• 제목/요약/키워드: E-M Analysis

검색결과 3,728건 처리시간 0.03초

3d-PD 패턴과 VHF/UHF PD 신호의 고찰 (The Analysis of VHF/UHF PD and 3d-PD Pattern)

  • 임장섭;박용석;최병하;한석균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.75-78
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

Purification and Characterization of Cop, a Protein Involved in the Copy Number Control of Plasmid pE194

  • Kwak, Jin-Hwan;Kim, Jung-Ho;Kim, Mu-Yong;Choi, Eung-Chil
    • Archives of Pharmacal Research
    • /
    • 제21권3호
    • /
    • pp.291-297
    • /
    • 1998
  • Cop protein has been overexpressed in Escherichia coli using a T7 RNA polymerase system. Purification to apparent homogeneity was achieved by the sequential chromatography on ion exchange, affinity chromatography, and reverse phase high performance liquid chromatography system. The molecular weight of the purified Cop was estimated as 6.1 kDa by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). But the molecular mass of the native state Cop was shown to be 19 kDa by an analytical high performance size exclusion chromatography, suggesting a trimer-like structure in 50 mM Tris-HCI buffer (pH 7.5) containing 100 mM NaCl. Cop protein Was calculated to contain $39.1% {\alpha}-helix, 16.8% {\beta}-sheet$, 17.4% turn, and 26.8% random structure. The DNA binding property of Cop protein expressed in E. coli Was preserved during the expression and purification process. The isoelectric point of Cop was determined to be 9.0. The results of amino acid composition analysis and N-terminal amino acid sequencing of Cop showed that it has the same amino acid composition and N-terminal amino acid sequence as those deduced from its DNA sequence analysis, except for the partial removal of N-terminal methionine residue by methionyl-aminopeptidase in E. coli.

  • PDF

Development of Main Steam Line Break Mass and Energy Release Analysis with RETRAN-3D Code

  • Park, Young-Chan;Kim, Yoo
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.93-100
    • /
    • 2003
  • An estimation methodology of the mass and energy (M/E) release due to the main steam line break (MSLB) has been developed with the RETRAN-3D code. In the case of equipment qualification (EQ), the over-estimated temperature would exceed the design limits of some cables or valves. In order to have a more flexible EQ profiles from the MSLB M/E release, the methodology with the best-estimated code was used. The major conditions affecting the MSLB M/E were found to be the initial SG level, heat transfer between primary and secondary sides, power level, operable protection system, main or auxiliary feedwater availability, and break conditions. The RETRAN-3D models were developed for the Kori unit 1 (KRN-1) which is typical two loop Westinghouse (WH) designed plant. Particularly, a detailed model of the steam generators was developed to estimate a more realistic two-phase heat transfer effect of the steam flow. After the modeling, the methodology has been developed through the sensitivity analyses. The M/E release data generated from the analyses have been used as the input to the inside containment pressure and temperature (P/T) analysis. According to the results at the point of view containment P/T, the Kori unit 1 can have more margin of 5∼15 ㎪ in pressure and 8∼15$^{\circ}C$ in temperature.

LiNbO$_3$ 광 도파로의 전계분포 및 설계에 관한 연구 (A Study on the electric field distribution of design of LiNbO$_3$ optical waveguide)

  • 강기성;소대화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.288-293
    • /
    • 2000
  • BPM simulation was used in order to fabricate the LiNbO$_3$optical waveguide with optical source of He-Ne laser(λ=0.6328[$\mu$m]). we observed electric field E$_{x}$, E$_{y}$ in the x,y-direction are simulated at the LiNbO$_3$substrate (X1 55[$\mu$m]$\times$Z1 5000[$\mu$m]), where the depth, width and buffer layer of waveguide are 0.2[$\mu$m],4[$\mu$m] and 0.02[$\mu$m] respectively. By applying these parameters of single waveguide to simulate a X-switch, we have chosen index change of 0.002, width of 3[$\mu$m] and angle of 0.4$^{\circ}$~0.6$^{\circ}$of optical waveguide and under these conditions, optical beam propagates cross-side at 0.4$^{\circ}$. When applied switching voltage of 25[V], optical beam of X-switch turns cross-side to bar-side at intersection angle 0.4$^{\circ}$, index change of 0.002, waveguide width of 3[$\mu$m], electrode gap 2[$\mu$m]. By the above results, we can obtain design conditions of theoretical analysis of an X-switch optical waveguide.e.e.

  • PDF

유한 요소법에 의한 속응 여자 초전도 발전기의 과도 특성 해석 (Transient Characteristic Analysis of Quick Response Extraction Type Superconducting Generator by Finite Element Method)

  • 김정철;한성진
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.26-31
    • /
    • 2000
  • This paper deals with finite element analysis of 2GVA superconducting generator which has slitted electrothermal shield in d-axis (SES). Three phase fault is considered torque of the S.C.G. Using the result, generator parameters are calculated by F.E.M. The results are compared with superconducting generator having conventional electrothermal shield (CES). The result shows that quick response excitation could be applied to superconducting generator with slitted electrothermal shield.

  • PDF

유한 요소법을 이용한 하모닉 모터(Harmonic side drive motor)의 토오크 특성 해석 (Finite Element Analysis of Torque Characteristics of Harmonic Side Drive Motor)

  • 윤서진;이은웅;이동주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.58-60
    • /
    • 1998
  • This paper analyzes the torque characteristics with the structure of harmonic side drive motor using by F.E.M and conformal mapping method. F.E.M and conformal analysis result are almost same. Through the results, we investigate how do design parameters variation affect torque characteristics.

  • PDF

갈랑가 뿌리 추출물의 항산화, 항노화 효과 및 W/O형 에멀젼에서 항산화 효과의 보존성 (Antioxidant and anti-aging effects of Alpinia galanga L. rhizome extracts and preservation of antioxidant effects in W/O type emulsion)

  • 윤선영;김봉환;장영아;김세기
    • Journal of Applied Biological Chemistry
    • /
    • 제66권
    • /
    • pp.424-435
    • /
    • 2023
  • 본 연구 결과 DPPH 라디칼 소거 활성은 갈랑가 뿌리 70% 에탄올 추출물(AG.E) 100 ㎍/mL 농도에서 81.8%이었으며 ABTS+ 라디칼 소거 활성은 AG.E 50 ㎍/mL의 낮은 농도에서 L-Ascorbic acid (AA)와 유사한 99.8%로 확인되었다. 항노화 활성을 측정하기 위하여 collagenase와 elastase 저해 활성을 측정한 결과 둘 모두에서 AG.E는 50 ㎍/mL의 낮은 농도부터 epigallocatechin (EGCG)보다 더 높은 저해 효과를 나타내었다. 특히 500 ㎍/mL 농도에서 EGCG 대비 3배 이상의 저해 효과를 보였다. CCD-986sk 세포내에서 AG.E의 항노화 효과를 검증하기 위해 UVB로 자극한 다양한 실험에서도 우수한 항노화 효과가 얻어졌다. RT-PCR을 통한 유전자 발현 분석 실험에서 COL1A mRNA 발현량은 AG.E 20 ㎍/mL 저농도에서 무첨가 대비 2.90배 증가시키는 결과가 얻어져 항노화관련 우수한 기능성 소재로 개발 가능성이 확인되었다. 제형에 소재의 적용 시 생리활성의 경시적 보전성에 대한 기초 연구로서 AG.E 및 AA등을 안정한 W/O type emulsion에 첨가하여 25 ℃ 항온조에 보관하면서 1일차, 30일차, 60일차에 DPPH와 ABTS+ 라디칼소거 활성을 측정한 결과 모두 경시적으로 항산화 효과가 높은수준 유지됨을 확인하였다.

운용된 전력케이블의 진단기술에 대한 와이블 분포해석 (The Analysis of Weibull Distribution on the Diagnosis Technology of Used Power Cable)

  • 임장섭;노성호;김지선;이재봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.47-47
    • /
    • 2010
  • 배전계통의 사고예방 기술은 전력수요 및 증설이 증가하고 있는 상황에서 시급히 확립되어야 한다. 특히 현장에서 시공되는 케이블은 시공과정의 관리가 쉽지 않을 뿐 아니라, 시공 중 발생될 수 있는 결함들을 검출하는 방법도 제한되어 있다. 본 연구에서는 국내에 도입된 진단방법을 통계적 방법으로 분석하고 효과적으로 점검할 수 있는 방법에 관한 검토하고자 한다.

  • PDF

유한 요소법에 의한 End-ring을 고려한 초고속 유도전동기의 설계 및 성능해석 (Design and Performance Analysis of High Speed Induction Motor considering end-ring by F.E.M.)

  • 정현호;김경호;구대현;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1007-1009
    • /
    • 2004
  • This paper describes the design and the performance analysis of high speed induction motor considering end-ring using F.E.M.. To investigate the flux distribution, the induced rotor current, the designed high speed induction motor is analyzed by 3-D F.E.M.. Also, to identify the design specification, the performance characteristic is analyzed and estimated into the torque, the current and the output power at the static and the transient state.

  • PDF

파일럿 규모의 하수 처리 공정별 E-screen Assay에 의한 에스트로겐 활성과 내분비계 장애물질의 농도 평가 (Estimation of Estrogenic Activity by E-screen Assay and Stepwise Analysis of Endocrine Disruptors in Pilot Sewage Treatment Plant)

  • 이지호;박종열;나진성;;이병천;김상돈
    • 대한환경공학회지
    • /
    • 제28권7호
    • /
    • pp.697-703
    • /
    • 2006
  • 물 재이용 목적으로 설계한 pilot scale의 하수 처리공정에서 배출되는 방류수 중 내분비계 장애물질을 GC/MS로 분석하였고, 처리 공정별로 제거율을 비교하였다. 각 처리 공정별 방류수에서 nonylphenol이 주로 검출되었고, 평균 $0.36{\sim}0.94$ ${\mu}g/L$으로 높게 검출되었으나, E2와 EE2는 처리수에서 정량 이하로 검출되었다. 내분비계 장애물질은 처리 공정별로 $50{\sim}100%$의 제거율을 보여주었다. E-screen assay에 의해 얻어진 양-반응 곡선에서 E2의 EC50값은 $9.0{\times}10^{-3}$ M로 bisphenol A와 p-octylphenol의 EC50값인 $2.736{\times}10^{-5}$ M, $9.760{\times}10^{-6}$ M에 비해 매우 높았다. 이는 알킬페놀류가 E2에 대한 상대적인 에스트로겐 활성도가 매우 낮음을 보여주었다. 환경 호르몬 농도와 이 물질의 상대적인 에스트로겐 활성도에 근거하여 계산된 에스트로겐 활성도(ng-EEQ/L)는 E-screen assay에 의해 실측한 총 에스트로겐 활성도(ng-EEQ/L)에 비해 평균 2배의 높은 활성도를 보여 주었다. 각 처리 공정별 방류수의 에스트로겐 활성도는 1 ng-EEQ/L 이하의 매우 낮은 활성도를 보여주었다.