• Title/Summary/Keyword: E Field Distribution

Search Result 486, Processing Time 0.033 seconds

PSF Deconvolution on the Integral Field Unit Spectroscopy Data

  • Chung, Haeun;Park, Changbom
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.58.4-58.4
    • /
    • 2019
  • We present the application of the Point Spread Function (PSF) deconvolution method to the astronomical Integral Field Unit (IFU) Spectroscopy data focus on the restoration of the galaxy kinematics. We apply the Lucy-Richardson deconvolution algorithm to the 2D image at each wavelength slice. We make a set of mock IFU data which resemble the IFU observation to the model galaxies with a diverse combination of surface brightness profile, S/N, line-of-sight geometry and Line-Of-Sight Velocity Distribution (LOSVD). Using the mock IFU data, we demonstrate that the algorithm can effectively recover the stellar kinematics of the galaxy. We also show that lambda_R_e, the proxy of the spin parameter can be correctly measured from the deconvolved IFU data. Implementation of the algorithm to the actual SDSS-IV MaNGA IFU survey data exhibits the noticeable difference on the 2D LOSVD, geometry, lambda_R_e. The algorithm can be applied to any other regular-grid IFS data to extract the PSF-deconvolved spatial information.

  • PDF

A Study on the electric field distribution of design of LiNbO$_3$ optical waveguide (LiNbO$_3$ 광 도파로의 전계분포 및 설계에 관한 연구)

  • 강기성;소대화
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.288-293
    • /
    • 2000
  • BPM simulation was used in order to fabricate the LiNbO$_3$optical waveguide with optical source of He-Ne laser(λ=0.6328[$\mu$m]). we observed electric field E$_{x}$, E$_{y}$ in the x,y-direction are simulated at the LiNbO$_3$substrate (X1 55[$\mu$m]$\times$Z1 5000[$\mu$m]), where the depth, width and buffer layer of waveguide are 0.2[$\mu$m],4[$\mu$m] and 0.02[$\mu$m] respectively. By applying these parameters of single waveguide to simulate a X-switch, we have chosen index change of 0.002, width of 3[$\mu$m] and angle of 0.4$^{\circ}$~0.6$^{\circ}$of optical waveguide and under these conditions, optical beam propagates cross-side at 0.4$^{\circ}$. When applied switching voltage of 25[V], optical beam of X-switch turns cross-side to bar-side at intersection angle 0.4$^{\circ}$, index change of 0.002, waveguide width of 3[$\mu$m], electrode gap 2[$\mu$m]. By the above results, we can obtain design conditions of theoretical analysis of an X-switch optical waveguide.e.e.

  • PDF

Ana1ysis of Temperature Distribution in Oil-immersed Self-cooled Transformer with Radiator (방열기를 갖는 유입자냉식 변압기의 온도분포 해석)

  • Kim, Joong-Kyoung;Hahn, Sung-Chin;Oh, Yeon-Ho;Park, Kyoung-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.755-756
    • /
    • 2006
  • This paper presents the temperature distribution of the oil-immersed self-cooled transformer with radiator performed by coupled magneto-fluid-thermal analysis. Particularly, 3D temperature distribution of cooling oil and sub-components under the natural convection is obtained by computational fluid dynamics analysis, while heat sources are predetermined by magnetic field analysis using F.E.M. The predicted temperature distribution of the power transformer model is compared with the measured data for verifying the validity of the proposed analysis.

  • PDF

Calculation of the Electromagnetic Wave Ields Near Electric Power Lines (전력선로 근방의 전자파 전자계 계산)

  • Kang, Dae-Ha;Lee, Young-Sik;Park, Jung-Eun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.79-88
    • /
    • 2008
  • In this study electromagnetic fields near electric power lines were derived by dipole antenna theory and electromagnetic fields near 3 phase power lines with vertical configurations were formulated and could be computed easily using these formula. It seems that those formula could be applicable to the consideration of electromagnetic fields during the design of transmission and distribution lines. Those formulated equations on elements of electromagnetic fields were applied to the model of a transmission-line system and were calculated by Matlab programs. The calculation results are follows. For variation of horizontal distance profiles of $E_y$ and $B_z$ are same each other, and also those of $B_y$ and $E_z$ are same each other. This means that coupled elements of E and B are perpendicular each other and have the propagation direction of the right-hand system such as $x{\rightarrow}E_y{\rightarrow}B_z$. Resultant electric field E is dominated by the element $E_y$ and resultant magnetic field B is dominated by the element $B_z$.

The Characteristic Analysis of the Ag/Bi-2223 Tape and the Flux damper in GTS Synchronous Motor through 3-Dimensional Magnetic Field Analysis Using F.E.M (3차원 자계분포해석을 이용한 고온초전도동기모터에서의 Ag/Bi-2223 Tape 및 Flux Damper의 특성해석)

  • 송명곤;윤용수;이상진;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.170-172
    • /
    • 2000
  • This paper deals with the characteristic analysis of the flux damper with respect to the load, and the stability of Ag/Bi-2223 tapes in a high-Tc superconducting (HTS) synchronous motor. To find out the magnetic field distribution in a detailed model of the actual motor, the experimentally measured currents of the armature and the field windings are used as input parameters. The simulation results show that the flux damper shields the time varying field up to 10%, reduces armature reactance during the motor operation and during load changes, improving the stable motor operation. And it was observed that the flux damper generates loss by means of leakage flux, but this is not significant and it doesn't degrade the performance of the TS synchronous motor.

  • PDF

Collection and Analysis of Automotive Field Reliability Data (자동차 필드데이터 수집 및 신뢰도 분석)

  • Kwon, Young-Il
    • Journal of Applied Reliability
    • /
    • v.8 no.1
    • /
    • pp.1-13
    • /
    • 2008
  • A methodology for collection and analysis of automotive field reliability data is presented. Automotive warranty system usually covers a pre-determined period of time and/or mileage accumulation. Therefore mileage information for the vehicles that have not experienced any failure or problems during the warranty period is not available. In this paper, a reliability analysis method using the estimated mileage distribution from an additional survey for vehicles that have not any record during the warranty period is proposed. Methods of reliability analysis using the warranty information collected under the EU and US warranty policies are also provided.

  • PDF

MRF-based Fuzzy Classification Using EM Algorithm

  • Lee, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.5
    • /
    • pp.417-423
    • /
    • 2005
  • A fuzzy approach using an EM algorithm for image classification is presented. In this study, a double compound stochastic image process is assumed to combine a discrete-valued field for region-class processes and a continuous random field for observed intensity processes. The Markov random field is employed to characterize the geophysical connectedness of a digital image structure. The fuzzy classification is an EM iterative approach based on mixture probability distribution. Under the assumption of the double compound process, given an initial class map, this approach iteratively computes the fuzzy membership vectors in the E-step and the estimates of class-related parameters in the M-step. In the experiments with remotely sensed data, the MRF-based method yielded a spatially smooth class-map with more distinctive configuration of the classes than the non-MRF approach.

Design and fabrication of race-track type field coil for the high temperature superconduction generator

  • Baik, S.K.;Jo, Y.S.;Ha, H.S.;Lee, E.Y.;Jeong, D.Y.;Kwon, Y.K.;Ryu, K.S.;Sohn, M.H.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.248-251
    • /
    • 2000
  • The fabrication and characteristics of HTS race-track type field coil for generators was carried out. Field coils are composed of 3 pancake coils wound by 37-filamental Bi-2223/Ag-alloy tapes. The winding machine is horizontal type. The critical currents (I$_c$) of the superconducting tapes were measured with variation of bending strain and external magnetic fields. I$_c$ of both whole field coils and 3 pancake coils were measured as a function of temperature. At 77K under the self-field, I$_c$ of whole field coils was 12A, while in the case of middle pancake coil, I$_c$ was 15A. The distribution of magnetic field B was obtained, using 3-D FEM. Our simulation showed that maximums of B${\bot}$A in x-y plane were locally distributed in both the upper and the lower coils. In addition, the fabrication processes and the characteristics of field coil are described.

  • PDF

Distribution characteristics of macroinvertebrates in an agricultural paddy field and irrigation pond ecosystems in a farmer's practice manual on the village of the Agricultural Environment Conservation Program (농업 환경보전 프로그램 대상마을의 논과 둠벙 생태계의 저서성대형무척추동물 분포 특성)

  • I-Chan Shin;Seung-Hyun Lee;Young-Mi Lee;Ji-Young Yoon;Sung-Jun Hong;Hyun-Jo Yoon;Sang-Goo Park;Eun-Jung Han
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.2
    • /
    • pp.148-156
    • /
    • 2022
  • Ecological occupation in irrigation ponds is a well-acknowledged fact that is essential for biodiversity conservation in agricultural ecosystems. However, there are few studies on the ecological functions and relationship between a paddy field and irrigation using macroinvertebrates in an environmentally friendly paddy field. The objective of this study is to identify the community and distribution characteristics of macroinvertebrates in an agricultural paddy field and irrigation pond ecosystems, and to provide basic data on the ecological function of an environmentally friendly paddy field. Macroinvertebrate sampling was conducted from May to September in an agricultural paddy field and irrigation pond in an environment-friendly paddy field in Boryeong city. We conducted a study to identify the distribution characteristics using macroinvertebrate species analysis, such as Functional Feeding Groups (FFGs), Habitat Oriented Groups (HOGs), rarefaction curve, and a two-way dendrogram. A total of 37 species of macroinvertebrates in 28 families, 13 orders were collected study during the period of the investigation. Dominant taxa of macroinvertebrates included Coleoptera, Hemiptera, and Odonata. In terms of FFGs, predators and gathering collectors accounted for approximately 70%, in relation to HOGs, and climbers and swimmers occupied more than 50% from both the paddy field and irrigation pond. With respect to the rarefaction curve, the irrigation pond (July) was high as E (S, 141)=18 species, while the paddy field (May) was comparatively low as E (S, 141)=9 species. In conclusion, our results revealed that macroinvertebrates, such as Notonecta triguttata, Peltodytes intermedius, Appasus major, Laccotrephes japonensis, Appasus japonicus, Sigara substriata, Enochrus simulans, and Sternolophus rufipes, were used as a habitat and spawning ground in both paddy field and irrigation pond. The irrigation pond appears to be a very important spawning ground for macroinvertebrates.

Improving Lifetime Prediction Modeling for SiON Dielectric nMOSFETs with Time-Dependent Dielectric Breakdown Degradation (SiON 절연층 nMOSFET의 Time Dependent Dielectric Breakdown 열화 수명 예측 모델링 개선)

  • Yeohyeok Yun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.4
    • /
    • pp.173-179
    • /
    • 2023
  • This paper analyzes the time-dependent dielectric breakdown(TDDB) degradation mechanism for each stress region of Peri devices manufactured by 4th generation VNAND process, and presents a complementary lifetime prediction model that improves speed and accuracy in a wider reliability evaluation region compared to the conventional model presented. SiON dielectric nMOSFETs were measured 10 times each under 5 constant voltage stress(CVS) conditions. The analysis of stress-induced leakage current(SILC) confirmed the significance of the field-based degradation mechanism in the low electric field region and the current-based degradation mechanism in the high field region. Time-to-failure(TF) was extracted from Weibull distribution to ascertain the lifetime prediction limitations of the conventional E-model and 1/E-model, and a parallel complementary model including both electric field and current based degradation mechanisms was proposed by extracting and combining the thermal bond breakage rate constant(k) of each model. Finally, when predicting the lifetime of the measured TDDB data, the proposed complementary model predicts lifetime faster and more accurately, even in the wider electric field region, compared to the conventional E-model and 1/E-model.