• 제목/요약/키워드: Dynamic voltage stability

검색결과 169건 처리시간 0.029초

Dynamic Element Matching을 적용한 Sigma Delta ADC에 관한 연구 (A Study on Sigma Delta ADC using Dynamic Element Matching)

  • 김화영;유장우;이용희;성만영;김규태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1222-1225
    • /
    • 2004
  • This paper presents multibit Sigma-Delta ADC using noise-shaped dynamic element matching(DEM). 5-bit flash ADC for multibit quantization in Sigma Delta modulator offers the following advantages such as lower quantization noise, more accurate white-noise level and more stability over single quantization. For the feedback paths consisting of DAC, the DAC element should have a high matching requirement in order to maintain the linearity performance which can be obtained by the modulator with a multibit quantizer. The DEM algorithm is implemented in such a way as to minimize additional delay within the feedback loop of the modulator Using this algorithm, distortion spectra from DAC linearity errors are shaped. Sigma Delta ADC achieves 82dB signal to noise ratio over 615H7z bandwidth, and 62mW power dissipation at a sampling frequency of 19.6MHz. This Sigma Delta ADC is designed to use 0.25um CMOS technology with 2.5V supply voltage and verified by HSPICE simulation.

  • PDF

에너지저장시스템을 이용한 전력계통의 과도안정도 향상 (Transient Stability Enhancement of Power System by Using Energy Storage System)

  • 서규석
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.26-31
    • /
    • 2017
  • 전력계통의 과도안정도를 향상시키기 위해 종래에는 무효전력 보상장치를 설치하는 방법을 주로 사용하였다. 전통적인 무효전력 보상장치 중 SVC(Static Var Compensator), 변압기의 탭 변환기는 값이 싸고 기계적 스위칭으로 동작하여 속도가 느리다는 단점이 있고, 전력전자기술을 바탕으로 하는 STATCOM(Static Synchronous Compensator)은 고속으로 동작할 수 있는 장점이 있어 최근에 각광을 받고 있지만 고가의 장치라는 단점이 있다. 또한, 무효전력 보상장치에 기반한 전통적인 방법은 무효전력만을 공급하여 과도안정도를 향상시키기에 대형 전동기의 트립에 의한 급격한 전압붕괴를 막을 수 없다. 반면에 에너지 저장시스템은 무효전력과 유효전력을 동시에 공급할 수 있다. 즉, 선로사고로 인하여 부하에 유효전력의 공급이 감소하는 것을 ESS을 통한 유효전력을 공급함과 동시에 적절한 무효전력의 공급을 통하여 과도안정도를 향상시킬 수 있다. 전력계통의 사고 시 유효전력의 빠른 공급은 과도안정도 향상에 매우 중요한 역할을 한다. 본 논문에서는 대형 전동기 부하와 같은 큰 동적부하를 가지는 전력계통에 대하여 에너지저장시스템을 사용한 과도안정도 향상방법을 제시한다. 또한, 유효전력과 무효전력을 보상하는 방법이 기존의 방법보다 더 효과적으로 과도안정도를 향상시킴을 확인하였다.

풍력터빈 발전기가 연계된 전력계통에서 에너지저장시스템이 과도안정도에 미치는 영향 (Transient Stability Enhancement of Power System by Using Energy Storage System)

  • 서규석
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.592-597
    • /
    • 2019
  • 전력계통의 과도안정도를 향상시키기 위한 종래의 방법은 STATCOM(Static Synchronous Compensator), SVC(Static Var Compensator)와 같은 무효전력 보상장치를 이용하는 것이다. 하지만 무효전력 보상장치에 기반한 전통적인 방법은 대형 전동기의 트립에 의한 급격한 전압붕괴를 막을 수 없다. 반면에 에너지 저장시스템은 무효전력과 유효전력을 동시에 공급할 수 있다. 전력계통의 사고 시 유효전력의 빠른 공급은 과도안정도 향상에 매우 중요한 역할을 한다. 본 논문에서는 대형 전동기부하와 같은 큰 동적부하를 가지는 전력계통에 대하여 에너지저장시스템을 사용한 과도 안정도 향상방법을 제시한다. 또한 유효전력과 무효전력을 보상하는 방법이 기존의 방법보다 더 효과적으로 과도 안정도를 향상시킴을 확인하였다.

복합전력계통 신뢰도평가에 있어서 확률론적 안전도연구 (Probabilistic Security Analysis in Composite Power System Reliability)

  • 김형철;차준민;김진오;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.46-48
    • /
    • 2005
  • This paper discusses a probabilistic method for power system security assessment. The security analysis relates to the ability of the electric power systems to survive sudden disturbances such as electric short circuits or unanticipated loss of system elements. It consists of both steady state and dynamic security analyses, which are not two separate issues but should be considered together. In steady state security analysis including voltage security analysis, the analysis checks that the system is operated within security limits by OPF (optimal power flow) after the transition to a new operating point. Until now, many utilities have difficulty in including dynamic aspects due to computational capabilities. On the other hand. dynamic security analysis is required to ensure that the transition may lead to an acceptable operating condition. Transient stability, which is the ability of power systems to maintain synchronism when subjected to a large disturbance. is a principal component in dynamic security analysis. Usually any loss of synchronism may cause additional outages and make the present steady state analysis of the post-contingency condition inadequate for unstable cases. This is the reason for the need of dynamic studies in power systems. Probabilistic criterion can be used to recognize the probabilistic nature of system components while considering system security. In this approach. we do not have to assign any predetermined margin of safety. A comprehensive conceptual framework for probabilistic static and dynamic assessment is presented in this paper. The simulation results of the Western System Coordinating Council (WSCC) system compare an analytical method with Monte-Carlo simulation (MCS).

  • PDF

The Design and Simulation of a Fuzzy Logic Sliding Mode Controller (FLSMC) and Application to an Uninterruptible Power System Control

  • Phakamach, Phongsak;Akkaraphong, Chumphol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.389-394
    • /
    • 2004
  • A Fuzzy Logic Sliding Mode Control or FLSMC for the uninterruptible power system (UPS) is presented, which is tracking a sinusoidal ac voltage with specified frequency and amplitude. The FLSMC algorithm combines feedforward strategy with the Variable Structure Control (VSC) or Sliding Mode Control (SMC) and fuzzy logic control. The control function is derived to guarantee the existence of a sliding mode. FLSMC has an advantage that the stability of FLSMC can be proved easily in terms of VSC. Furthermore, the rules of the proposed FLSMC are independent of the number of system state variables because the input of the suggested controller is fuzzy quantity sliding surface value. Hence the rules of the proposed FLSMC can be reduced. The simulation results illustrate that the purposed approach gives a significant improvement on the tracking performances. It has the small overshoot in the transient and the smaller chattering in the steady state than the conventional VSC. Moreover, its can achieve the requirements of robustness and can supply a high-quality voltage power source in the presence of plant parameter variations, external load disturbances and nonlinear dynamic interactions.

  • PDF

실 변수 엘피트주의 유전알고리즘을 이용한 SVC 계통의 안정화 장치의 설계 (A Design of Power System Stabilization for SVC System Using a RVEGA)

  • 정형환;허동렬;이정필;왕용필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권7호
    • /
    • pp.324-332
    • /
    • 2001
  • In this paper, it is suggested that the selection method of parameter of Power System Stabilizer(PSS) with robustness in low frequency oscillation for Static VAR Compensator(SVC) using a Real Variable Elitism Genetic Algorithm(RVEGA). A SVC, one of the Flexible AC Transmission System(FACTS), constructed by a fixed capacitor(FC) and a thyristor controlled reactor(TCR), is designed and implemented to improve the damping of a synchronous generator, as well as controlling the system voltage. The proposed PSS parameters are optimized using RVEGA in order to maintain optimal operation of generator under the various operating conditions. To decrease the computational time, real variable string is adopted. To verify the robustness of the proposed method, we considered the dynamic response of generator speed deviation and generator terminal voltage by applying a power fluctuation and three-phase fault at heavy load, normal load and light load. Thus, we prove the usefulness of proposed method to improve the stability of single machine-infinite bus with SVC system.

  • PDF

광역 전력계통 감시를 위한 상위 Master System 설계 (Design and Development of Master System for Monitoring Wide Area Power System)

  • 김상태;이정현;김지영;이동철;문영환;김태현;윤재영;김동준;이병준;한상욱;남해곤;심관식;이승재;진보건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.243-245
    • /
    • 2006
  • In this paper, the master system of Wide Area Monitoring System in order to prevent reaching a fault influence toward power system is proposed. This system has three real time algorithms and a on-line one using i-piu transfer data and provides operators with various understandable monitoring viewers in HMI based on raw data and algorithm results.

  • PDF

전력시스템 안정도 향상을 위한 SVC용 GA-LQ 제어기 설계 (Design of GA-LQ Controller in SVC for Power System Stability Improvement)

  • 허동렬;박인표;정문규;정형환;안병철;김해재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.226-228
    • /
    • 2002
  • This paper presents a new control approach for designing a coordinated controller for static VAR compensator system. A SVC constructed by a Fixed Capacitor and a Thyristor Controlled Reactor is designed and implemented to improve the damping of a synchronous generator, as well as controlling the system voltage. A design of linear quadratic controller based on optimal controller depends on choosing weighting matrices. A coordinated optimal controller is achieved by minimizing a quadratic performance index using dynamic programming techniques. The selection of weighting matrices is usually carried out by trial and error which is not a trivial problem. We proposed a efficient method using GA of finding weighting matrices for optimal control law. Thus, we prove the usefulness of proposed method to improve the stability of single machine-infinite bus with SVC system.

  • PDF

A Study on Single-bit Feedback Multi-bit Sigma Delta A/D converter for improving nonlinearity

  • Kim, Hwa-Young;Ryu, Jang-Woo;Jung, Min-Chul;Sung, Man-Young
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.57-60
    • /
    • 2004
  • This paper presents multibit Sigma-Delta ADC using Leslie-Singh Structure to Improve nonlinearity of feedback loop. 4-bit flash ADC for multibit Quantization in Sigma Delta modulator offers the following advantages such as lower quantization noise, more accurate white-noise level and more stability over single quantization. For the feedback paths consisting of DAC, the DAC element should have a high matching requirement in order to maintain the linearity performance which can be obtained by the modulator with a multibit quantizer. Thus a Sigma-Delta ADC usually adds the dynamic element matching digital circuit within feedback loop. It occurs complexity of Sigma-Delta Circuit and increase of power dissipation. In this paper using the Leslie-Singh Structure for improving nonliearity of ADC. This structure operate at low oversampling ratio but is difficult to achieve high resolution. So in this paper propose improving loop filter for single-bit feedback multi-bit quantization Sigma-Delta ADC. It obtained 94.3dB signal to noise ratio over 615kHz bandwidth, and 62mW power dissipation at a sampling frequency of 19.6MHz. This Sigma Delta ADC is fabricated in 0.25um CMOS technology with 2.5V supply voltage.

  • PDF

시화호 조력발전소 신설에 따른 전력계통 특성 및 경제적 이득 분석 (A Study on Power System Characteristics and Economic Benefit by Operating the New SIHWA Tidal Power Plant)

  • 김규호;송경빈;김상민;이성무;최홍석
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.791-796
    • /
    • 2012
  • This paper presents the various analysis of the power system for operating the new SIHWA tidal power plant. In the analysis of the power system, summer load condition of 2011 is used. Especially, power flow, fault current, voltage and contingency of SIHWA tidal power plant area are analyzed by using PSS/E and there is no problem for the dynamic stability simulation. The new SIHWA tidal power plant is located in near metropolitan area where about 43% amount of the system load is consumed. Therefore, transmission losses are reduced. In addition, system marginal price can be lowered by generating the new SIHWA tidal power plant. The generation pattern of the SIHWA tidal plant is analyzed and the changes of generation are presented for various water levels by control of the rotor angle alpha and beta in water wheel generator.