• Title/Summary/Keyword: Dynamic shear strength

Search Result 268, Processing Time 0.023 seconds

상온 재활용 아스팔트 혼합물의 적정 유화아스팔트 함량 선정 연구 (Study on the Proper Emulsified-Asphalt Content for a Cold-Recycling Asphalt Mixture)

  • 양성린;손정탄;이강훈
    • 한국도로학회논문집
    • /
    • 제20권1호
    • /
    • pp.47-58
    • /
    • 2018
  • PURPOSES : The purpose of this study is to evaluate the mechanical properties of a cold-recycling asphalt mixture used as a base layer and to determine the optimum emulsified-asphalt content for ensuring the mixture's performance. METHODS : The physical properties (storage stability, mixability, and workability) of three types of asphalt emulsion (CMS-1h, CSS-1h, and CSS-1hp) were evaluated using the rotational viscosity test. Asphalt emulsion residues, prepared according to the ASTM D 7497-09 standard, were evaluated for their rheological properties, including the $G*/sin{\delta}$and the dynamic shear modulus (${\mid}G*{\mid}$). In addition, the Marshall stability, indirect tensile strength, and tensile-strength ratio (TSR) were evaluated for the cold-recycling asphalt mixtures fabricated according to the type and contents of the emulsified asphalt. RESULTS : The CSS-1hp was found to be superior to the other two types in terms of storage stability, mixability, and workability, and its $G*/sin{\delta}$ value at high temperatures was higher than that of the other two types. From the dynamic shear modulus test, the CSS-1hp was also found to be superior to the other two types, with respect to low-temperature cracking and rutting resistance. The mixture test indicated that the indirect tensile strength and TSR increased with the increasing emulsified-asphalt content. However, the mixtures with one-percent emulsified-asphalt content did not meet the national specification in terms of the aggregate coverage (over 50%) and the indirect tensile strength (more than 0.4 MPa). CONCLUSIONS : The emulsified-asphalt performance varied greatly, depending on the type of base material and modifying additives; therefore, it is considered that this will have a great effect on the performance of the cold-recycling asphalt pavement. As the emulsified-asphalt content increased, the strength change was significant. Therefore, it is desirable to apply the strength properties as a factor for determining the optimum emulsified-asphalt content in the mix design. The 1% emulsified-asphalt content did not satisfy the strength and aggregate coverage criteria suggested by national standards. Therefore, the minimum emulsified-asphalt content should be specified to secure the performance.

축력과 반복수평력을 받는 격자강판 내진보강벽의 구조거동에 관한 실험적 연구 (An Experimental Study on the Structural Behavior of Steel Grid Shear Wall subjected to Axial Force and Cyclic Lateral Load)

  • 박정우;심기철;박진영;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제25권6호
    • /
    • pp.525-532
    • /
    • 2012
  • 근래에 지어진 건축물의 경우 지진에 대한 안전성을 확보하고 있지만 1983년 개정이전의 건축물은 내진설계가 미반영 되어 있어 지진에 대해 매우 취약하다. 본 연구에서는 내진성능이 부족한 기존 건축물의 지진 발생 시의 안전성 확보를 위한 내진보강 방안으로 격자강판 내진보강벽을 제안한다. 축력과 반복수평력을 받는 성능실험을 수행하였으며, 실험체는 벤치마크 용도로 순수 철근콘크리트 프레임(BM-RC)과 프레임 내부에 격자강판 내진보강벽(SW-RC)을 설치한 2개의 실험체를 제작하여 실험을 수행하였고, 축력과 횡하중 가력을 위하여 500kN용량의 엑츄에이터 2대와 2,000kN용량의 엑츄에이터 1대를 사용하였다. 실험결과를 통해 벤치마크 실험체와 비교하여 강도, 강성, 연성 및 에너지소산능력을 평가하였다.

철근 콘크리트와 강판 콘크리트 간 이질접합부로 구성된 구조물의 휨 및 전단거동 특성 연구 (A Study on Flexural and Shear Behavior of the Structure with Steel Plate Concrete to Reinforced Concrete Member's Connection)

  • 황경민;이경진;이종보;원덕희
    • 대한토목학회논문집
    • /
    • 제32권5A호
    • /
    • pp.267-275
    • /
    • 2012
  • 본 연구에서는 철근 콘크리트 벽과 강판 콘크리트 벽이 이질접합 형태로 만나는 구조물의 휨 및 전단거동 특성을 검토하기 위하여 L형과 I형 타입의 실험체를 제작하고 구조실험을 수행하였다. 실험 시, 지진하중 등에 대한 실험체의 동적특성을 확인하기 위하여 Push 및 Pull을 반복하는 싸이클 하중을 구현하고자 하였다. L형 실험체에 대한 면외 휨 실험결과, 실험체의 공칭강도를 초과하는 휨 성능을 발휘하였으며, 이에 따라 설계에 적용된 수직철근의 미겹침 이음길이의 타당성을 확인할 수 있었다. 한편, 강판 콘크리트 벽 내에 수평철근의 배근 유무를 변수로 구성한 두 개의 I형 실험체에 대한 면내 전단 실험결과, 수평철근의 배근 유무에 상관없이 공칭강도를 초과하는 전단 성능을 보였다.

Seismic performance assessment of the precast concrete buildings using FEMA P-695 methodology

  • Adibi, Mahdi;Talebkhah, Roozbeh
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.55-67
    • /
    • 2022
  • The precast reinforced concrete frame system is a method for industrialization of construction. However, the seismic performance factor of this structural system is not explicitly clarified in some existing building codes. In this paper, the seismic performance factor for the existing precast concrete building frame systems with cast-in-situ reinforced shear walls were evaluated. Nonlinear behavior of the precast beam-column joints and cast-in-situ reinforced shear walls were considered in the modeling of the structures. The ATC-19's coefficient method was used for calculating the seismic performance factor and the FEMA P-695's approach was adopted for evaluating the accuracy of the computed seismic performance factor. The results showed that the over-strength factor varies from 2 to 2.63 and the seismic performance factor (R factor) varies from 5.1 to 8.95 concerning the height of the structure. Also, it was proved that all of the examined buildings have adequate safety against the collapse at the MCE level of earthquake, so the validity of R factors was confirmed. The obtained incremental dynamic analysis (IDA) results indicated that the minimum adjusted collapse margin ratio (ACMR) of the precast buildings representing the seismic vulnerability of the structures approximately equaled to 2.7, and pass the requirements of FEMA P-695.

현행 내진설계 규준의 수평강도 요구에 대한 평가 (Evaluation of the Strength Required in Current Seismic Design Code)

  • 한상환;오영훈;이리형
    • 전산구조공학
    • /
    • 제10권4호
    • /
    • pp.281-290
    • /
    • 1997
  • 현행 내진설계 규준에서 사용하고 있는 반응수정계수는 설계지진하중과 유사한 지진발생시 구조물이 비선형 거동을 하도록 탄성응답에서 요구되는 밑면전단력 값을 낮추는 계수라 할 수 있다. 따라서 반응수정계수는 하중저감계수(force reduction factor)라고 할 수 있으며, 이러한 값들은 경험적으로 결정된 것이어서 예상지진에 대하여 구조설계자가 설계한 건물이 어느정도의 비선형 거동을 할지는 예측하기가 힘들다. 본 연구에서는 목표가 되는 연성비(target ductility ratio)에 따라 요구되는 밑면전단력의 값을 구하고 이를 규준에서 요구하는 값과 비교할 것이다. 만약 요구되는 값이 규준 값 보다 크다면 이는 구조물이 가지는 부가강도(overstrength)나 잉여력(redundancy)이 담당해야 한다. 모멘트연성골조 건물을 설계한 후 이를 push-over 해석에 의하여 부가강도를 찾아 보아 요구강도와 비교할 것이다.

  • PDF

Analysis of behavioral characteristics of liquefaction of sand through repeated triaxial compression test and numerical analysis

  • Hyeok Seo;Daehyeon Kim
    • Geomechanics and Engineering
    • /
    • 제38권2호
    • /
    • pp.165-177
    • /
    • 2024
  • Liquefaction phenomenon refers to a phenomenon in which excess pore water pressure occurs when a dynamic load such as an earthquake is rapidly applied to a loose sandy soil ground where the ground is saturated, and the ground loses effective stress and becomes liquid. The laboratory repetition test for liquefaction evaluation can be performed through a repeated triaxial compression test and a repeated shear test. In this regard, this study attempted to evaluate the effects of the relative density of sand on the liquefaction resistance strength according to particle size distribution using repeated triaxial compression tests, and additional experimental verification using numerical analysis was conducted to overcome the limitations of experimental equipment. As a result of the experiment, it was confirmed that the liquefaction resistance strength increased as the relative density increased regardless of the classification of soil, and the liquefaction resistance strength of the SP sample close to SW was quite high. As a result of numerical analysis, it was confirmed that the liquefaction resistance strength increased as the confining pressure increased under the same relative density, and the liquefaction resistance strength did not decrease below a certain limit even though the confining pressure was significantly reduced at a relatively low relative density. This is judged to be due to a change in confining pressure according to the depth of the ground. As a result of analyzing the liquefaction resistance strength according to the frequency range, it was confirmed that there was no significant difference from the laboratory experiment results in the basic range of 0.1 to 1.0 Hz.

대규모 지하굴착시 쐐기파괴로 인하여 발생하는 토압에 관한 연구 (A Study on the Rock Pressure Wedge Failure During Ground Excavation)

  • 이승호
    • 지질공학
    • /
    • 제11권1호
    • /
    • pp.1-11
    • /
    • 2001
  • 우리나라 지질의 특성은 토층의 두께가 얇아서 보통 10m이상만 굴착해도 암반층이 나타나므로 대규모 지하굴착 공사시 암반층에서의 토압분포 산정방법이 절실하게 요구되고 있는 실정이다. 그러나, 암반층 암압산정시 기존의 경험식인 Terzaghi-Peck, Tschebotarioff식 등을 그대로 적용하는 것은 암반층의 점착력을 대부분 무시하게 되므로 실제 강도를 과소 평가하게 된다. 따라서 암반에서의 절리경사각, 절리면 전단강도, 지반 상재하중등을 고려한 쐐기형 블럭(Wedge Block)의 수평활동력을 산정하는것이 실제 암반층 토류구조물에 작용하는 암압과 근접할 것으로 판단된다. 본 연구에서는 뒷채움 흙이 점착력을 갖는 흙인 경우 쐐기형상으로 파괴가 일어난다고 가정하여 Coulomb 토압이론을 확장하여 힘의 평형 조건을 이용해 Prakash-Saran(1963)이론과 절리면의 전단강도 결정공식 $\tau$=c+$\sigma$tan $\Phi$를 적용해서 암반층에 작용하는 암압을 산정하였다. 산정된 이론식을 이용하여 절리면 충전물의 상태 변화에 따른 절리면 전단 강도와 절리경사각을 바꿔가면서 해석해 본 결과, 암반층은 자체의 점착력과 내부마찰각이 크므로 절리방향과 경사각이 굴착면을 향해 어떻게 정해지느냐에 따라서 토압이 작용하기도 하고 작용하지 않을 수도 있다. 본 연구에서 산정된 이론식은 향후 절리면 전단강도 산정시 필요한 강도정수, 절리면의 방위와 상태, 과잉측압, 동적하중, 지진을 비롯한 많은 지반정수(Parameter)들을 보다 엄밀히 산정하고, 특히 암반층에 작용하는 지하수위 효과등을 고려하여, 실제 현장에서 계측된 많은 자료와의 분석을 통해 그 적용성이 검토되어야 할 것으로 판단된다.

  • PDF

Effects of thermal aging on mechanical properties of laminated lead and natural rubber bearing

  • Kim, Dookie;Oh, Ju;Do, Jeongyun;Park, Jinyoung
    • Earthquakes and Structures
    • /
    • 제6권2호
    • /
    • pp.127-140
    • /
    • 2014
  • Laminated rubber bearing is very popular base isolation of earthquake engineering pertaining to the passive structural vibration control technologies. Rubber used in fabricating NRB and LRB can be easily attacked by various environmental factors such as oxygen, heat, light, dynamic strain, and organic liquids. Among these factors, this study carried out thermal aging test to investigate the effect of thermal aging on the mechanical properties of laminated rubber bearings in accelerated exposure condition of $70^{\circ}C$ temperature for 168 hours. The compressive-shear test was carried out to identify the variation of compressive and shear properties of the rubber bearings before and after thermal aging. In contrast to tensile strength and elongation tests, the hardness of rubber materials showed the increasing tendency dependent on exposure temperature and period. Based on the test results, the property changes of rubber bearing mainly aged by heat are quantitatively presented.

Ball Grid Array 보드 어셈블리의 동적굽힘 신뢰성에 미치는 언더필의 영향 (Effects of Underfills on the Dynamic Bending Reliability of Ball Grid Array Board Assembly)

  • 장재원;방정환;유세훈;김목순;김준기
    • 한국재료학회지
    • /
    • 제21권12호
    • /
    • pp.650-654
    • /
    • 2011
  • In this paper, the effects of conventional and newly developed elastomer modified underfill materials on the mechanical shock reliability of BGA board assembly were studied for application in mobile electronics. The mechanical shock reliability was evaluated through a three point dynamic bending test proposed by Motorola. The thermal properties of the underfills were measured by a DSC machine. Through the DSC results, the curing condition of the underfills was selected. Two types of underfills showed similar curing behavior. During the dynamic bending reliability test, the strain of the PCB was step increased from 0.2% to 1.5% until the failure circuit was detected at a 50 kHz sampling rate. The dynamic bending reliability of BGA board assembly using elastomer modified underfill was found to be superior to that of conventional underfill. From mechanical and microstructure analyses, the disturbance of crack propagation by the presence of submicron elastomer particles was considered to be mainly responsible for that result rather than the shear strength or elastic modulus of underfill joint.

다층구조형 아크릴 점착제의 분자량 및 피착재 종류에 따른 접착특성 (Adhesion Properties on the Molecular Weight and Various Substrates of Multi-layered Structural Acrylic Adhesive)

  • 김동복
    • 폴리머
    • /
    • 제39권3호
    • /
    • pp.514-521
    • /
    • 2015
  • 본 연구는 자동차, 건축, 디스플레이 부품 접합 등에 사용되는 다층구조형 양면 점착테이프에 대한 것으로 UV 경화에 의해 제조된 아크릴폼 기재에 용제 건조형 점착제(AD)를 양면에 붙이고 피착제 종류에 따른 박리강도와 전단접착강도를 고찰하였다. AD 종류와 기재 조성에 따른 접착력 변화 및 피착재로 사용한 플라스틱에 대한 접착력을 고찰한 결과, AD의 분자량(MW)이 증가할수록 박리강도 및 전단접착강도가 증가하였으나 약 65만 이상의 MW를 가진 AD는 접착력이 감소하는 거동을 보였다. 양면 점착테이프에 사용된 AD층 두께가 얇을수록 온도감소와 함께 높은 물성 값을 보였다. 기재와 AD와의 계면접합 특성은 MW 615000(AD-4)을 사용한 것이 가장 우수하였으며, MW가 615000보다 낮으면 기재인 아크릴 폼과의 계면이 분리되는 결과를 보였다. 따라서 본 연구에서 검토한 다층구조형 양면 점착테이프는 표면에너지가 낮은 플라스틱 부품 및 곡면 부위에 적용가능한 산업분야에 유용하게 사용될 수 있을 것으로 판단된다.