• Title/Summary/Keyword: Duty effectiveness

Search Result 114, Processing Time 0.021 seconds

Alternating Pressure Profile Characteristics of Powered Pressure Ulcer Preventing Devices (동력형 욕창예방제품의 교대부양 압력 프로파 특성)

  • Won, Byeong-Hee;Song, Chang-Seop
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.639-646
    • /
    • 2010
  • The APAM's quantitative effectiveness and comparative study in preventing and treating pressure ulcer has not been sufficiently evaluated mainly because of uncertainty of pressure load input and lack of interpretation of dynamic perfusion recovery characteristics of soft tissue. The purpose of this paper was to quantify and analyze the alternating pressure characteristics of APAM as a preventive measure for pressure ulcers. To quantify the alternating load to human body, we introduced alternating pressure profile concept and developed parametric model of the profile. Regarding pressure level and cycle time, 3 global and 7 local periodic parameters were used to define the profile such as light, standard, typical and heavy duty profile shape. Pressure impulse ratio of light duty is the lowest but pressure fluctuation is significantly high. For the same duty shape, contact conditions are changed with alternating cycle time and more dramatically in shorter alternating cycle time conditions. We can conclude that if we use shorter alternating cycle time on APAM's operation we can get more positive effects regarding to inflated contact time condition. We proposed the quantitative methods on tissue viability study of external loading by simultaneous measurement of interface pressure and tissue perfusion with proper alternating pressure profile conditions.

The Evaluation on the Extent of Dieticians' Application of the Curriculum of the Food and Nutrition Department to their Work (충청북도 지역의 학교급식과 산업체급식 영양사의 직무 수행시 식품영양학전공 교과내용의 활용도 평가)

  • Kim, Gi-Nam;Lee, Myeong-Sun;Lee, Yeong-Eun
    • Journal of the Korean Dietetic Association
    • /
    • v.11 no.4
    • /
    • pp.430-439
    • /
    • 2005
  • The purposes of this study were to evaluate the extent of dieticians' application of the curriculum of the food and nutrition major to their work and to suggest improvement measures for more efficiently applicable curriculum. A questionnaire survey of 552 dieticians at school food service and industry food service operations in Korea was conducted and 178 completed questionnaires were available for the purpose of the statistical evaluation. Statistical analyses were made of raw data by way of using the SPSS/win 7.2 program. The main results of this study were summarized as follows : Dietitian’s job could be categorized into 11 duties and 92 task elements. The application level was ranked at a level between 3 point and 4 pont(out of 5 scale) in the most area of the 92 task elements. Out of 11 duties, duty of sanitation management was applied at the highest level, while duty of nutrition education and duty of consultation management were utilized at the lowest level. Compared with the industry food service dieticians, dieticians at school food service operations employed the curriculum at the higher level. The effectiveness of experiments and practicum curriculum was ranked at the lower level than 3 point(out of 5 scale).

  • PDF

A Study of Design Single Phase Boost Converter Controller for Compensated Load Current and Duty (부하전류와 듀티를 보상하는 단상 PFC 부스트 컨버터 제어기 설계)

  • Lim, Jae-Uk;Lee, Seung-Tae;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.527-534
    • /
    • 2017
  • This paper proposes a new DC link voltage controller for a single-phase power factor correction (PFC) boost converter. The load current of the PFC boost converter affects the capacitor current, whereas the load current changes the output voltage. However, previous works that compensate output current have failed to consider the relationship between load current and duty. Thus, they also fail to maintain a constant output voltage if the load fluctuates under the conditions of a non-rated input voltage. By considering the duty in the load current compensation, the proposed method improves the load transient response regardless of the input voltage. To demonstrate its effectiveness, the proposed method is compared with other control methods by conducting PSM simulations and experiments under a rapidly changing load.

A Modularized Charge Equalizer Using the Magnetizing Energy of the Multi-Winding Transformer (다권선 변압기의 자화 에너지를 이용한 모듈화 전하 균일 장치)

  • Lim, Chang-Soon;Hyun, Dong-Seok;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.393-400
    • /
    • 2012
  • The modularized equalizers normally use additional components among the modules in the long series-connected lithium-ion battery string. In these approaches, the overall systems are heavy, bulky, and high-priced. Furthermore, the losses related to additional components decrease the system efficiency. To avoid these problems, a modularized equalizer, which has no additional components among the modules, is required. This paper proposes a novel control scheme using the magnetizing energy of the multi-winding transformer for the module equalization. In this scheme, the high duty cycle is applied to the module where the voltage is higher than the reference voltage and the low duty cycle is applied to the module where the voltage is lower than the reference voltage. Due to the different duty cycle, more electric charges are transferred from high voltage module to the low voltage module during the turn-off switching interval. Using the proposed control scheme, the equalizer system does not suffer from the size, cost, and loss related to the modularization. The experimental results are provided to verify the effectiveness of the proposed modularized equalizer.

A Sensorless MPPT Control Using an Adaptive Neuro-Fuzzy Logic for PV Battery Chargers (태양광 배터리 충전기를 위한 적응형 신경회로망-퍼지로직 기반의 센서리스 MPPT 제어)

  • Kim, Jung-Hyun;Kim, Gwang-Seob;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.349-358
    • /
    • 2013
  • In this paper, the sensorless MPPT algorithm is proposed where the performance of varied duty ratio change has been improved using multi-layer neuro-fuzzy that aligns with neuro-fuzzy based optimized membership function. Since the change of duty ratio of sensorless MPPT is varied by using the neuro-fuzzy, the MPPT response speed is faster than the convectional method and is able to reduce the steady-state ripple. The neuro fuzzy controller has the response characteristics which is superior to the existing fuzzy controller, because of the usage of the optimal width of the fuzzy membership function. The effectiveness of the proposed method has been verified by simulations and experimental results.

Model-Based Predictive Control for Interleaved Multi-Phase DC/DC Converters (다상 인터리브드 DC/DC 컨버터를 위한 모델기반의 예측 제어기법)

  • Choi, Dae-Keun;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.415-421
    • /
    • 2014
  • This study proposes a model-based predictive control for interleaved multi-phase DC/DC converters. The power values necessary to adjust the output voltage in the succeeding are predicted using a converter model. The output power is controlled by selecting the optimal duty cycle. The proposed method does not require controller loops and modulators for converter switching. This method can control the converter by calculating the optimal duty cycle, which minimizes the error between the reference and actual output voltage. The effectiveness of the proposed method is verified through simulations and experiments.

High Step-Up Converter with Hybrid Structure Based on One Switch

  • Hwu, K.I.;Peng, T.J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1566-1577
    • /
    • 2015
  • A novel high step-up converter is presented herein, which combines the conventional buck-boost converter, the charge pump capacitor and the coupling inductor. By doing so, a quite high voltage conversion ratio due to not only the turns ratio but also the duty cycle, so as to increase design feasibility. It is noted that the denominator of the voltage conversion ratio is the square of one minus duty cycle. Above all, there is no voltage spike across the switch due to the leakage inductance and hence no passive or active snubber is needed, and furthermore, the used switch is driven without isolation and hence the gate driving circuit is relatively simple, thereby upgrading the industrial application capability of this converter. In this paper, the basic operating principles and the associated mathematical deductions are firstly described in detail, and finally some experimental results are provided to demonstrate the effectiveness of the proposed high step-up converter.

A Study on the Effects for the Job Satisfaction in the Special Duty of the Private Security (특수경비원의 직무만족 영향요인에 관한 연구)

  • Ahn, Hwang-Kwon
    • Korean Security Journal
    • /
    • no.7
    • /
    • pp.213-231
    • /
    • 2004
  • This paper is concerned with the influence in the job satisfaction by the organization, the job specialty and the self-devotion in the special duty of private security. Today's society is required more intensive security in the diversity, the complexity and the uncertainty, but the public security service could not supply enough for what the society requires. In this circumstance more specialized and special trained security services are demanded from private security industry. With the concerns, this study is based on actual survey. The study is telling us that there is much relationship in job satisfaction between each element. Which means that 1) there is some different from personality, 2) there is much influence in self-devotion by job specialty, 3) there some effectiveness in job satisfaction by job specialty, 4) there is some influence in job satisfaction by self-devotion, and 5) job satisfaction is affected by job specialty and self-devotion.

  • PDF

A Study on Development of Balanced ScoreCard Personnel Assessment Using of Safety Duty Using National Competency Standards (국가직무능력표준을 활용한 안전직무의 BSC 인사평가 시스템 개발)

  • Yang, Kwang Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.27-34
    • /
    • 2015
  • If examining utilization by completion of National Competency Standards development, efforts are made so as to organize curriculum matched to education or training and perform subjects based on competence unit educationally in specialized high schools, colleges and university. However, National Competency Standards is insignificantly utilized in enterprises and on the spot due to characteristics of occupation type and diversity of process. This thesis intended to measures of safety efficiency improvement of final enterprise through the human resources assessment system of National Competency Standards based enterprise. Therefore, various methodologies were introduced and results of analysis by Balanced ScoreCard method were suggested for policy measures improving final safety efficiency. The results of this analysis are expected to make contribution to improving the effectiveness of the government's industrial safety and health policies through the establishment of systematic safety and health systems according to the risk level of individual business.

A Simple Grid-Voltage-Sensorless Control Scheme for PFC Boost Converters

  • Nguyen, Cong-Long;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.712-721
    • /
    • 2014
  • This paper introduces a simple grid-voltage-sensorless control scheme for single-phase power factor correction (PFC) boost converters. The grid voltage waveform is obtained based on the dc output voltage, the switching duty ratio, and a phase-lead compensator. In addition, the duty ratio feedback is utilized to obtain the unity input power factor and the zero harmonic current. The proposed control scheme is designed and mathematically analyzed based on a small-signal model of PFC boost converters. To verify the effectiveness of the proposed control scheme, several simulations and experiments are carried out in two applications: an industrial power system with a 60 Hz grid frequency and a commercial aircraft application with a 400 Hz grid frequency.