• Title/Summary/Keyword: Duty control

Search Result 857, Processing Time 0.031 seconds

A Study on the Ecosystem Conservation based on Natural Environment Investigation of Jinhae Area Troops (진해지역부대 자연환경조사를 통한 생태계 보전에 관한 연구)

  • Jang, Cheol-Hyeon;Yu, Jong-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.733-738
    • /
    • 2014
  • Within the scope that does not interfere with the performance of basic duty, the military has been actively supporting the national policy for the conservation of the natural environment in accordance with the "military environmental protection guidelines". Since there is a lack of information regarding inhabitation for wild fauna and flora, field investigations of the natural environment at Jinhae local unit were performed three times in 2003. As a result of the investigation, lycoris sanguinea as flora, marten, otter, and leopard cat as mammalia, and accipiter soloensis, accipiter gentilis schvedow, accipiter gularis, buteo hemilasius, falco tinnunculus and terpsiphone atrocaudata as bird were confirmed to inhabit. For the conservation of the natural ecosystem, the expansion of research for natural ecosystems within the military unit is required. Additionally, environmental pollution can be prevented through the proper maintenance of basic environmental facilities including sewage treatment facilities, soil pollution control facilities, and waste storage facilities. In cooperation with local governments and private organizations, the natural cleansing action and sustainable wildlife conservation should be expanded.

HYBRID LIGHT DUTY VEHICLES EVALUATION PROGRAM

  • Trigui, R.;Badin, F.;Jeanneret, B.;Harel, F.;Coquery, G.;Lallemand, R.;Ousten, JP.;Castagne, M.;Debest, M.;Gittard, E.;Vangraefshepe, F.;Morel, V.;Baghli, L.;Rezzoug, A.;Labbe, J.;Biscalia, S.
    • International Journal of Automotive Technology
    • /
    • v.4 no.2
    • /
    • pp.65-75
    • /
    • 2003
  • A HEV evaluation program, funded by ADEME, was carried out by a group of Laboratories of different specialties in order to evaluate and compare consumption, emission and component technologies of the three first HEVs put on the market (Toyota Prius, Nissan Tino and Honda Insight). This paper presents the results obtained until now. These results show good consumption and emission performance of the tested vehicles compared to conventional ones. The energy management seems to be globally the same for the three vehicles excepting for cold stans where the Insight allows a very earlier stop of the engine compared to the Tino and especially to the Prius. A mapping of the engine consumption of the Prius and the Insight was performed in order to furnish data for the simulation models. The Permanent Magnet motors of the Prius and Tino have different number of pair poles and then different emf at a given speed. The low emf values of the Prius allow operation at high speed with less field weakening control than for the Tino. The inverters of the Prius and the Tino, controlled by a PWM at respectively 5 kHz and 7 kHz switching frequency, are made of IGBTs with high commutation performances.

Congruent LiNbO3 Crystal Periodically Poled by Applying External Field (외부전계 인가에 의한 조화용융조성 LiNbO3 결정의 주기적 분극반전)

  • Kwon, Soon-Woo;Yang, Woo-Seok;Lee, Hyung-Man;Kim, Woo-Kyung;Lee, Han-Young;Yoon, Dae-Ho;Song, Yo-Seung
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.11 s.282
    • /
    • pp.749-752
    • /
    • 2005
  • When an electric field higher than a characteristic coercive field is applied to a ferroelectric such as $LiNbO_3$, the orientation of the spontaneous polarization is reversed, which causes the reversal of the sign of odd-rank tensor properties such as electro-optic and nonlinear optic coefficients. A fabrication process of insulator and periodic external field assisted poling of a z-cut $LiNbO_3$ have been optimized for a periodic $180^{\circ}$ phase inversion along z-axis. The poling jig and the poling control system, fully controlled by a computer, for high quality and reproducible PPLN fabrication have been devised. Periodically polarization reversed PPLN was adjusted based on the fabricated thickness of insulator. The poling structure of PPLN was observed under a microscope after etching PPLN samples by an etching solution ($HF:HNO_3$ = 1 : 2) for about 15 min.

Field Study of Effects of Night Shifts on Cognitive Performance, Salivary Melatonin, and Sleep

  • Kazemi, Reza;Motamedzade, Majid;Golmohammadi, Rostam;Mokarami, Hamidreza;Hemmatjo, Rasoul;Heidarimoghadam, Rashid
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.203-209
    • /
    • 2018
  • Background: Night shift work is associated with many problems such as sleep deprivation, sleepiness, decreased cognitive performance, increased human errors, and fatigue. This study set out to measure cognitive performance, melatonin rhythms, and sleep after different consecutive night shifts (7 vs. 4) among control room operators (CORs). Methods: The participants included 60 CORs with a mean age of 30.2 years (standard deviation, 2.0) from a petrochemical complex located in Southern Iran. Cognitive performance was assessed using the n-back task and continuous performance test. To evaluate melatonin, saliva was collected and tested by enzyme-linked immunosorbent assay. To assess sleep and sleepiness, the Pittsburgh Sleep Quality Index and Karolinska Sleepiness Scale were used, respectively. Results: Individuals who worked 7 consecutive night shifts had a significantly better cognitive performance and sleep quality than those who worked 4 consecutive night shifts. However, salivary melatonin profile and sleepiness trend were not affected by shift type. Conclusion: The main duty of CORs working night shifts at the studied industry included managing safety-critical processes through complex displays; a responsibility that demands good cognitive performance and alertness. It is suggested that an appropriate number of consecutive night shifts in a rotating shift system should be planned with the ultimate aim of improving CROs performance/alertness and enhancing safety.

Etch Characteristics of $SiO_2$ by using Pulse-Time Modulation in the Dual-Frequency Capacitive Coupled Plasma

  • Jeon, Min-Hwan;Gang, Se-Gu;Park, Jong-Yun;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.472-472
    • /
    • 2011
  • The capacitive coupled plasma (CCP) has been extensively used in the semiconductor industry because it has not only good uniformity, but also low electron temperature. But CCP source has some problems, such as difficulty in varying the ion bombardment energy separately, low plasma density, and high processing pressure, etc. In this reason, dual frequency CCP has been investigated with a separate substrate biasing to control the plasma parameters and to obtain high etch rate with high etch selectivity. Especially, in this study, we studied on the etching of $SiO_2$ by using the pulse-time modulation in the dual-frequency CCP source composed of 60 MHz/ 2 MHz rf power. By using the combination of high /low rf powers, the differences in the gas dissociation, plasma density, and etch characteristics were investigated. Also, as the size of the semiconductor device is decreased to nano-scale, the etching of contact hole which has nano-scale higher aspect ratio is required. For the nano-scale contact hole etching by using continuous plasma, several etch problems such as bowing, sidewall taper, twist, mask faceting, erosion, distortions etc. occurs. To resolve these problems, etching in low process pressure, more sidewall passivation by using fluorocarbon-based plasma with high carbon ratio, low temperature processing, charge effect breaking, power modulation are needed. Therefore, in this study, to resolve these problems, we used the pulse-time modulated dual-frequency CCP system. Pulse plasma is generated by periodical turning the RF power On and Off state. We measured the etch rate, etch selectivity and etch profile by using a step profilometer and SEM. Also the X-ray photoelectron spectroscopic analysis on the surfaces etched by different duty ratio conditions correlate with the results above.

  • PDF

A Multi-Load Shoring Characteristic Using Novel Buck-Boost Chopper Circuit (새로운 승·강압 초퍼 회로를 이용한 부하 다분할 특성)

  • Suh, Ki-Young;Mun, Sang-Pil;Kwon, Soon-Kurl;Lee, Hyun-Woo;Jung, Sang-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.42-48
    • /
    • 2005
  • A DC-DC converter is being widely used for various household appliances and for industry applications. The DC-CC converter is powered from single battery, and the voltage is varied according to the purpose. In the vehicle, various accessories whose electric power is different are being un4 Thus, plural number of DC-DC converter should be provided, so these situations bring complicated circuits, and accordingly, higher cost. Under such backgrounds, in this paper, we propose a novel buck-boost chopper circuit with simply configuration which can supply to two or more different output loads. The propose chewer circuit can control output voltages by controlling duty ratio by using typically two switching devices, which is composed by single boost-switch and single buck-switch. The output voltage can be controlled widely. A few modified circuits developed from the fundamental circuit are represented including the general multi-load circuit. And all this merits and appropriateness was proved by computer simulation and experience.

An Improved Process System to File a Claim in Construction Projects (건설공사 시 클레임 제기를 위한 프로세스 시스템 개선 방안)

  • Bang, Taewon;Lee, Jaeseob
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.3
    • /
    • pp.22-32
    • /
    • 2017
  • Judging from the past cases, the contractor has frequently suffered losses caused by disapproved requests or reduced payments since it has not known the conditions of the contract or it has filed a claim to the owner without any proper claim system. Therefore, the existing claim process needs to be reformed. In order to reform the claim process, the contractor should consolidate the organizational structure, grant accurate duty assignments to the claims manager, implement regular staff training on how to deal with claims. In addition to this reformation, the contractor needs to improve the management of construction period and process control, and manage related documents thoroughly. Regular meetings are also necessary in claims. This study attempts to prove the effectiveness of the reformed process applied to Project "A", where the owner was responsible for the delayed supply of materials, inaccurate oral instructions, insufficient information on the work, and frequent changes of design. The project was completed in 96 months, which was extended by 34 months from the initial construction period of 62 months. The reformed claim process is expected to be of great help not only to largescale construction works but also to smallscale ones.

Privacy Protection Scheme of Healthcare Patients using Hierarchical Multiple Property (계층적 다중 속성을 이용한 헬스케어 환자의 프라이버시 보호 기법)

  • Shin, Seung-Soo
    • Journal of Digital Convergence
    • /
    • v.13 no.1
    • /
    • pp.275-281
    • /
    • 2015
  • The recent health care is growing rapidly want to receive offers users a variety of medical services, can be exploited easily exposed to a third party information on the role of the patient's hospital staff (doctors, nurses, pharmacists, etc.) depending on the patient clearly may have to be classified. In this paper, in order to ensure safe use by third parties in the health care environment, classify the attributes of patient information and patient privacy protection technique using hierarchical multi-property rights proposed to classify information according to the role of patient hospital officials The. Hospital patients and to prevent the proposed method is represented by a mathematical model, the information (the data consumer, time, sensor, an object, duty, and the delegation circumstances, and so on) the privacy attribute of a patient from being exploited illegally patient information from a third party the prevention of the leakage of the privacy information of the patient in synchronization with the attribute information between the parties.

Health Behavior and Perception of Therapeutic Restrictions in Chronically Ill Children and Their Parents (만성질환 아동과 부모의 치료적 제한에 대한 인식과 건강행위)

  • Park, Eun-Sook;Im, Yeo-Jin;Im, Hye-Sang;Oh, Won-Oak
    • Child Health Nursing Research
    • /
    • v.12 no.3
    • /
    • pp.405-416
    • /
    • 2006
  • Purpose: The purpose of this study was to explore health behavior and perception of therapeutic restrictions in chronically ill children and their parents in Korea. Method: Nine children with chronic disease and of six of their parents were interviewed using semi-structured a questionnaire. The data were analyzed using explorative content analysis. Results: Health behaviors related to therapeutic restrictions was classified into four domains, and the perceptions of therapeutic restrictions into two domains. The domains regarding compliance in health behavior with therapeutic restrictions included control-centered restrictions (maintaining food limitations, avoiding harmful environments, restriction on physical activity, restriction on social activity, restriction on learning activity), and everyday pursuit of balance(preference for healthy diet, maintaining a regular life style, maintaining a standard body weight, pursuing psychological well-being, family participation). Domains regarding perception of therapeutic restrictions included obstacles to growth and development (bridled life, opportunity deprivation, prevented from playing proper role), origin of conflict (tenacity, conflict, stressor, cover-up), task for normal life (doing proper duty), and everyday affairs (becoming ordinary, familiarity). Conclusion: This study will help to enhance understanding the behavior and perception of therapeutic restrictions by chronically ill children and their families and to establish educational programs and counseling for these children and their families.

  • PDF

A Novel Prototype of Duty Cycle Controlled Soft-Switching Half-Bridge DC-DC Converter with Input DC Rail Active Quasi Resonant Snubbers Assisted by High Frequency Planar Transformer

  • Fathy, Khairy;Morimoto, Keiki;Suh, Ki-Young;Kwon, Soon-Kurl;Nakaoka, Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.89-97
    • /
    • 2007
  • This paper presents a new circuit topology of active edge resonant snubbers assisted half-bridge soft switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed half-bridge high frequency PWM inverter with a high frequency planar transformer link in addition to input DC busline side power semiconductor switching devices for PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC buslines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, a high switching frequency IGBTs can be actually selected in the frequency range of 60 kHz under the principle of soft switching. The performance evaluations of the experimental setup are illustrated practically. The effectiveness of this new converter topology is proved for such low voltage and large current DC-DC power supplies as DC bus feeding from a practical point of view.