• Title/Summary/Keyword: Dust cleaning

Search Result 115, Processing Time 0.026 seconds

A Basic Research for the Development of Cleaning Agent for Stone Made Cultural Property (석조 문화재 보존 처리용 세정제 개발에 관한 기초연구)

  • Cho, Heon-young;Xia, Yong-mei
    • Journal of Conservation Science
    • /
    • v.11 no.1 s.14
    • /
    • pp.28-37
    • /
    • 2002
  • The cleaning in conservation treatment of cultural heritage is very important process. For the best conservation treatment of cultural heritage, except having a good detergency, the cleaning agent must be able to keep the heritage from the secondary deposition and re-soiling, damage and etc. In this paper, the dust (lichen, algae, dust, etc.) on the surface of stone made heritage was treated with some kinds of solvents and analyzed with FT-IR to develop a cleaning agent for stone made cultural heritage. And the cleaning ability to the dust and the corrosion ratio to the granite of the cleaning agent was investigated. Nonionic surfactants were good for treatment of stone-made cultural heritage. The reason is that nonionic surfactants are stable in acidic solution, and possess low reactivity with the compound of stone and low possibility to the second contamination, and build up the reactivities of acids and oxidants. A new cleaning agent composed with $H_2O_2/HF/NP-10$ shows a good cleaning ability for the conservation treatment of stone made cultural heritage.

  • PDF

Investigation of Job Satisfaction and Hazardous Factors of Aircraft Cleaning Worker (항공기 청소 노동자의 작업 만족도 및 유해인자 조사)

  • Choi, Yeonhak;Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.174-184
    • /
    • 2020
  • Objectives: The purpose of this study was to improve the working environment by identifying the work satisfaction of the cleaning workers of the aircraft and measuring and assessing the harmful factors of the cleaning process. Methods: We asked 23 cleaning companies for questionnaires and got 100 answers from 5 companies. The A-E Airline health manager has been contacted to establish a site survey schedule. The in-flight and lounge were measured using direct reading equipment. The harmful factor to be measured are noise, dust, temperature, volatile organic compound, total airborne bacteria, and total airborne bacteria. Results: Uncomfortable positions when replacing blanket, cleaning the table, and cleaning the floor have been identified as factor that reduce work satisfaction. Noise when replacing newspapers and cleaning toilets has been identified as a factor that lowers work satisfaction. Temperature and humidity were found to reduce work satisfaction during in-flight disinfection. Measurements of aircraft cabin and lounge with direct read equipment have shown that none of the items exceed the exposure criteria. Conclusions: As a result of measuring direct-reading equipment, no items exceeded the exposure criteria for each harmful factor. A clear survey of the working environment is required based on the results, and additional research is needed using personal sample measurement.

A Study on the Oil-mist/Smoke Collecting Module for the Pure Energy Recycling (청정에너지 회수용 유증기/매연 포집모듈에 관한 연구)

  • Kim, Myung-Soo;Ohkura, Shigenobu;Ham, Koung-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.279-284
    • /
    • 2009
  • Traditionally, so-called "industrial waste gases", such ad exhaust from boilers at industrial installations and a large quantity of soot discharged from power station, before their release into the atmosphere, have been on occasion subjected to an air cleaning process to remove fine particles that may pollute the atmosphere (such as mist and dust containing various powdery or oily substances and moisture from industrial waste gases). The release of industrial waste gases containing these particles directly into the atmosphere poses a serious threat to the earth environment; and recovery of these noxious substances is required by law in some countries and local governments. in urban areas, air pollution from automobile exhaust and others creates a serious condition. Some homes are equipped with and use indoor air purifiers. In many of the kitchens of restaurants, smoke generated during cooking and otherwise contaminated air are cleansed by air purifiers before being released outside or recycled inside. For the dust collecting devices to recover the fine particles contained in contaminated air, the cause for air pollution and how to purify air, many types based on various principles are known. Specifically, classified based on theories of particle collection, filtration, gravity, inertia, centrifugation, electricity, and cleaning types are cited as available processes. Among them, an appropriate type is selected according to the size or type of fine particles to be collected and conditions for installation. For the efficiency of dust collection, a filtration system (by using bag filters and others) and electric system are particularly outstanding and are therefore used widely in various areas of industry. In this research, rotary type high performance oil mist and smoke collecting system with self auto cleaning device equipped with the cleaning fluid spraying section is investigated.

  • PDF

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

A Study on the Effect of Dust Precharging on Filtration Performance

  • Park, Y.O;Park, S.J.;Lee, J.H.;Kim, S.D.;Park, H.S.;Park, H.K.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.53-59
    • /
    • 2001
  • A hybrid dust-collector combining electrostatic charging with fabric filtration method was developed, and its performance characteristics were evaluated in this study. Charged particles build porous dendritic structure on the surfaces of filter by electrostatic attraction, increasing the collection efficiency of dust particles and reducing the pressure drop through the deposited dust layer and filter media. The cleaning performance of the dust layer is improved because the dendritic structured dust layer can be removed more easily by pulse jet cleaning flow. The results of the experiment showed a reduction of fine particle emission of 37% and the energy saving of 13% by precharging dust particles before filtration.

  • PDF

Preparation and Evaluation of Self-cleaning Fabrics using Photocatalyst and Superhydrophobic Finishing (광촉매와 초발수 처리를 이용한 셀프클리닝 섬유의 제조 및 평가)

  • Jeong, Euigyung;Woo, Heejoo;Cho, Seungbin;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.30 no.4
    • /
    • pp.288-293
    • /
    • 2018
  • This study reported the dual functional self-cleaning PET fabrics prepared from $TiO_2$ and hexadecyltrimethoxysilane treatment, which have photodegradation and superhydrophobicity on the fabric surface. Phodegradation and superhydrophobicity of the resulting fabric were compared with $TiO_2$ or silane treated fabrics. The dual functional self-cleaning PET fabric showed less photodegradation than the $TiO_2$ treated fabric. However, the dual functional self-cleaning fabrics showed superior superhydrophobicity to silane treated fabric with increased water contact angle and significantly decreased roll-off angle. This suggested that the dual functional PET fabric has a great potential to be the commercialized self-cleaning fabric because it is repellent to soil or dust and even if soil or dust is adsorbed on the fabric surface, it can be removed by water rolling off on the surface or photodegradation by the photocatalyst.

3-Dimensional Finite Element Analysis for Collecting Structure of Combustible Metal Dust During Explosion (가연성 금속분진 폭발시 저장 및 포집용 구조물에 대한 3차원 유한요소 해석)

  • Jang, Chang-Bong;Yong, Jong-Won;Baek, Jong-Bae;Kwon, Hyuck-Myun;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.5
    • /
    • pp.19-24
    • /
    • 2011
  • Due to the latest industrial flow comes mainly switch to high-tech industries, combustible metals as Al, Mg, Li, Zn more require to use for the aircraft, car, cell phones, electronics and others. As a result, Increasing the processing of combustible metals due to increase in amount of combustible metals giving rise dust explosions also. Most Explosions caused by combustible metal dust, occurred in air cleaning device of local exhaust ventilation to capture and store the combustible dust. Therefore, this study was conducted to present and analyze technically that deformation and rupture shape of air cleaning device structure by Finite Element Analysis(FEA) rather than a simple prediction, in case of explosion occurs in an air cleaning device.

A Study on Airborne Dust and Asbestos Concentrations in Subway Stations in Seoul Area (서울시 지하철 구내의 공기중 분진 농도에 관한 연구)

  • 백남원;박두용;장익선;신용철;이정인
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.2
    • /
    • pp.1-12
    • /
    • 1988
  • Airborne dust and asbestos fiber concentrations were determined in subway stations located in Seoul area. Two stations, such as Eulchiro 4-Ka Station of Line #2, constructed during a period of 1980-1984 and Hyehwa Station of Line #4, opened in 1985, were selected. The results of the study are as follows. 1. Daily time-weighted average (TWA) concentrations of airborne dusts from 07:00 to 20:00 hours in Line #2 and Line #4 were 0.43$\pm$0.08 mg/m$^3$ and 0.37$\pm$0.12 mg/m$^3$, respectively. Thus, the dust levels in Line #2 were significantly higher than the levels in Line #4 (p < 0.05). 2. Dust levels in the morning (07:00-11:00 hours), noon (11:00-16:00 hours) and in the evening (16:00-20:00 hours) in Line #2 were 0.47$\pm$0.17 mg/m$^3$, 0.37$\pm$0.08 mg/m$^3$, and 0.46$\pm$0.07 mg/m$^3$ respectively. Thus, dust levels in the morning and evening (i.e., during rush hours) were significantly higher than levels in the noon (p < 0.02). However, there was no such difference in dust levels by time in Line #4. 3. Airborne total dust concentrations were well below the occupational health standard of 10 mg/m$^3$, however, the levels were exceeding the ambient air standard recommended by the Korean Environment Administration. 4. All of airborne asbestos fiber concentrations were equal to or below 0.005 fibers/cc. The levels are within both occupational health standards and U.S. EPA criteria. 5. A consideration should be given to the improvements of cleaning methods (such as use of vacuum cleaning instead of brushing) and the existing ventilation (such as more air change and filtration of supply air) for a reduction of dust levels. 6. It is recommended that routine monitoring of airborne dusts and asbestos fibers be conducted because more dusts and asbestos fibers can be produced in the air due to the deterioration of facilities by age and water damage in future.

  • PDF

Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System (원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교)

  • Kim Sang-Do;Park Young-Ok;Kang Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

Cleanup Quantification Method for Evaluation of Window Cleaning Work (유리창 청소작업 평가를 위한 청결도 정량화 방안)

  • Kim, Kyoon-Tai;Jun, Young-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.320-321
    • /
    • 2018
  • In the past, the results of window cleaning work have been judged subjective and complaints about cleaning results are being raised. In this study, we tried to quantify the evaluation of the cleaning result. For the quantification of the evaluation, a colorimeter was selected and the basic experiment was carried out. In addition, this study examined the use of standard dust powder for artificial production of contaminants in glasses. Further evaluation and analysis will be carried out to quantify the evaluation criteria of the cleaning results.

  • PDF