• 제목/요약/키워드: Dual Energy X-ray

검색결과 303건 처리시간 0.035초

골밀도 측정의 올바른 임상 적용 (Clinical Application of Bone Mineral Density Measurement)

  • 김덕윤
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.275-281
    • /
    • 2004
  • Compared with the earlier technique of dual photon absorptiometry (DPA) using $^{153}Gd$ radionuclide source, dual energy X-ray absorptiometry (DXA) has advantages of higher precision, accuracy and shorter scanning time. Despite the change from DPA to DPX, the nuclear medicine physicians has remained one of major suplier of this service due to long-standing use of DPA. Among many kinds of bone densitometries, DXA is the "gold standard" for the noninvasive diagnosis of osteoporosis. Especially there is no role for peripheral devices in the monitoring of patients on therapy. But, there are some areas of controversy related to the application of DXA, such as proper site of measurement, accurate interpritation, appropriate use of T-score, and the reference population young database. And the accuracy, precision, and quality control issues relating to bone density measurement are important subjects. To address these issues, the International Society for Clinical Densitometry (ISCD) has convened two Position Development Conferences and addressed official positions. This review deals the key elements of ISCD position paper and other important issues on the management of bone densitometry.

신생아 골밀도에 관한 연구 - 재태 연령과 출생 체중에 따른 골밀도의 차이 - (A Study on the Bone Density in Newborn Infants - Difference of the Bone Mineral Density according to the Gestational Age and the Birth Weight -)

  • 이은실;신손문;문한구;박용훈;최광해
    • Journal of Yeungnam Medical Science
    • /
    • 제14권2호
    • /
    • pp.383-392
    • /
    • 1997
  • 미숙아를 포함한 신생아에서의 재태 연령에 따른 골밀도의 차이를 관찰하여 향후 대사성 골질환의 진단을 기초 자료로 삼기 위하여, 1995년 3월 1일부터 1997년 2월 28일까지 영남대학교 의과대학 부속병원에서 출생한 신생아 중 자궁내 성장 발육 이상 소견이 없고, 생후 1주일이내에 골밀도 측정이 가능하였던 53명을 대상으로 이중에너지 X-선 흡수계측법 (dual energy X-ray absorptiometry, DXA, X-R 26, Norland, U.S.A.)을 사용하여 생후 1주일내의 요추에서의 골밀도를 측정하여 다음과 같은 결과를 얻었다. 1. 골밀도는 성별에 따른 차이는 없었고, 재태 연령군별 골밀도는 재태 연령 28-30주군의 $0.149{\pm}0.009g/cm^2$에서부터 39-41주군의 $0.229{\pm}0.034g/cm^2$까지 재태 연령의 증가에 따라 함께 증가를 보여 33-34주군과 35 - 36주군 사이를 제외한 재태 연령군별 골밀도는 유의한 차이를 보였으며 (p<0.05), 재태 연령이 28주 3일에서 41주 3일로 증가함에 따라 골밀도는 직선적인 상관관계를 나타내었다 ($Y=7.5{\times}10^{-3}X-0.082$, r=0.7018, p<0.001). 2. 출생체중별 골밀도는 1,000-1,499그람군의 골밀도는 $0.158{\pm}0.020g/cm^2$을 나타내었고, 3,500-4,000그람군의 골밀도는 $0.251{\pm}0.021g/cm^2$를 나타내어 출생 체중군별 골밀도는 1,000-1,499그람군과 1,500-1,999그람군 사이를 제외한 모든 체중군별로 유의한 차이를 나타내었다 (p<0.05). 출생체중이 1,250그람으로부터 3,880그람까지 증가하는데 따라 골밀도는 유의하게 증가하며 직선적인 상관관계를 나타내었다 ($Y=3.9{\times}10^{-5}X+0.093$, r=0.7296, p<0.001). 재태연령이 증가할수록, 출생체중이 증가할수록 골밀도가 증가하는 것을 관찰하였으며, 이는 향후 미숙아를 포함하는 신생아에 대한 골밀도 변화를 관찰하는 기초 자료가 될 수 있다고 생각된다.

  • PDF

한국 과체중 및 비만 여성의 휴식대사량 측정 및 예측값의 비교 (Comparison of Predicted and Measured Resting Energy Expenditure in Overweight and Obese Korean Women)

  • 박지숙;임정은
    • 대한지역사회영양학회지
    • /
    • 제23권5호
    • /
    • pp.424-430
    • /
    • 2018
  • Objectives: The purpose of this study was to compare predictions and measurements of the resting energy expenditure (REE) of overweight and obese adult women in Korea. Methods: The subjects included 65 overweight or obese adult women ranging in age from 20~60 with a recorded body mass index (BMI) of 23 or higher. Their height, weight, waist-hip ratio, and blood pressure were measured. The investigator also measured their body fat, body fat percentage, and body composition of total weight without fat using Dual energy X-ray absorptiometry (DXA) and measured resting energy expenditure by indirect calorimetry. Measured resting energy expenditures were compared with predictions from six methods: Harris-Benedict, Mifflin, Owen, WHO-WH, Henry-WH, and KDRI. Results: Harris-Benedict predictions showed the smallest differences from measured resting energy expenditure at an accurate prediction rate of 70%. The study analyzed regression between measured resting energy expenditure and body measurements including height, weight and age. The formula proposed by this research is as follows: Proposed REE equation for overweight and obese Korean women = $721-(1.5{\times}age)+(0.4{\times}height)+(9.9{\times}weight)$. Conclusions: These findings suggest that age is a significant variable when predicting resting energy expenditure in overweight and obese women. Therefore, prediction of resting energy expenditure should consider age when determining energy requirements in overweight and obese women.

The LaserFIB: new application opportunities combining a high-performance FIB-SEM with femtosecond laser processing in an integrated second chamber

  • Ben Tordoff;Cheryl Hartfield;Andrew J. Holwell;Stephan Hiller;Marcus Kaestner;Stephen Kelly;Jaehan Lee;Sascha Muller;Fabian Perez-Willard;Tobias Volkenandt;Robin White;Thomas Rodgers
    • Applied Microscopy
    • /
    • 제50권
    • /
    • pp.24.1-24.11
    • /
    • 2020
  • The development of the femtosecond laser (fs laser) with its ability to provide extremely rapid athermal ablation of materials has initiated a renaissance in materials science. Sample milling rates for the fs laser are orders of magnitude greater than that of traditional focused ion beam (FIB) sources currently used. In combination with minimal surface post-processing requirements, this technology is proving to be a game changer for materials research. The development of a femtosecond laser attached to a focused ion beam scanning electron microscope (LaserFIB) enables numerous new capabilities, including access to deeply buried structures as well as the production of extremely large trenches, cross sections, pillars and TEM H-bars, all while preserving microstructure and avoiding or reducing FIB polishing. Several high impact applications are now possible due to this technology in the fields of crystallography, electronics, mechanical engineering, battery research and materials sample preparation. This review article summarizes the current opportunities for this new technology focusing on the materials science megatrends of engineering materials, energy materials and electronics.

Fractal dimension analysis on CBCT scans for detecting low bone mineral density in postmenopausal women

  • Carvalho, Bruno Fontenele;de Castro, Julia Goncalves Koehne;de Melo, Nilce Santos;Figueiredo, Paulo Tadeu de Souza;Moreira-Mesquita, Carla Ruffeil;de Paula, Ana Patricia;Sindeaux, Rafael;Leite, Andre Ferreira
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.53-60
    • /
    • 2022
  • Purpose: The aim of this study was to compare the fractal dimension (FD) measured at 2 bone sites (second cervical vertebra and mandible) on cone-beam computed tomography (CBCT). The research question was whether FD could serve as an accessory tool to refer postmenopausal women for densitometric analysis. Therefore, the reliability and accuracy of FD were evaluated. Materials and Methods: In total, 103 postmenopausal women were evaluated, of whom 52 had normal bone mineral density and 51 had osteoporosis, according to dual X-ray absorptiometry of the lumbar spine and hip. On the CBCT scans, 2 regions of interest were selected for FD analysis: 1 at the second cervical vertebra and 1 located at the mandible. The correlations between both measurements, intra- and inter-observer agreement, and the accuracy of the measurements were calculated. A P value less than 0.05 was considered to indicate statistical significance for all tests. Results: The mean FD values were significantly lower at the mandibular region of interest in osteoporotic patients than in individuals with normal bone mineral density. The areas under the curve were 0.644 (P=0.008) and 0.531 (P=0.720) for the mandibular and vertebral sites, respectively. Conclusion: FD at the vertebral site could not be used as an adjuvant tool to refer women for osteoporosis investigation. Although FD differed between women with normal BMD and osteoporosis at the mandibular site, it demonstrated low accuracy and reliability.

리튬이온전지용 양극활물질 LiNi0.83 Co0.11Mn0.06O2의 전기화학적 특성에 미치는 Ce와 Nd 희토류 금속의 단독 혹은 이중 도핑효과 (Effect of Single and Dual Doping of Rare Earth Metal Ce and Nd Elements on Electrochemical Properties of LiNi0.83 Co0.11Mn0.06O2Cathode Lithium-ion Battery Material)

  • 김유영;하종근;조권구
    • 한국분말재료학회지
    • /
    • 제26권1호
    • /
    • pp.49-57
    • /
    • 2019
  • Layered $LiNi_{0.83}Co_{0.11}Mn_{0.06}O_2$ cathode materials single- and dual-doped by the rare-earth elements Ce and Nd are successfully fabricated by using a coprecipitation-assisted solid-phase method. For comparison purposes, non-doping pristine $LiNi_{0.83}Co_{0.11}Mn_{0.06}O_2$ cathode material is also prepared using the same method. The crystal structure, morphology, and electrochemical performances are characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive spectrometer (EDS) mapping, and electrochemical techniques. The XRD data demonstrates that all prepared samples maintain a typical ${\alpha}-NaFeO_2$-layered structure with the R-3m space group, and that the doped samples with Ce and/or Nd have lower cation mixing than that of pristine samples without doping. The results of SEM and EDS show that doped elements are uniformly distributed in all samples. The electrochemical performances of all doped samples are better than those of pristine samples without doping. In addition, the Ce/Nd dual-doped cathode material shows the best cycling performance and the least capacity loss. At a 10 C-rate, the electrodes of Ce/Nd dual-doped cathode material exhibit good capacity retention of 72.7, 58.5, and 45.2% after 100, 200, and 300 cycles, respectively, compared to those of pristine samples without doping (24.4, 11.1, and 8.0%).

조영증강 $^{18}F$-FDG PET/CT가 이중에너지 X-선 흡수 계측법을 이용한 골밀도 및 체성분 측정에 미치는 영향 (Effect of Contrast-Enhanced $^{18}F$-FDG PET/CT on Measurements of Whole Body Bone Mineral Density and Body Composition by Dual-Energy X-Ray Absorptiometry)

  • 김성수;이선도;이남주;신용철;모은희;이춘호
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.7-11
    • /
    • 2012
  • PET/CT에 사용되는 방사성의약품 FDG와 CT 조영제가 DXA를 이용하여 측정하는 BMC, BMD, TFM, LBM 등의 결과에 미치는 영향을 알아보고자 하였다. 2011년 12월부터 2012년 3월까지 본원 PET/CT를 시행한 환자 중 본 연구에 참여를 동의한 환자 총 22명을 대상으로 하였다. 실험은 두 집단으로 나누어 실험을 진행하였는데 첫 번째 집단은 17명으로 PET/CT 용 방사성의약품인 FDG 정맥 주사 전에 WB DXA를 시행한 다음 FDG 정맥주사 1시간 후 CT 조영제 사용 없이 PET/CT (Non-Contrast Enhancement $^{18}F$-FDG PET/CT)시행 후 즉시 다시 WB DXA를 진행하였다. 두 번째 집단은 총 5명으로 첫 번째 집단과 마찬가지로 FDG 정맥 주사 전 WB DXA를 시행한 다음 FDG 정맥 주사 1시간 후 CT 조영제 사용하여 PET/CT (Contrast Enhancement $^{18}F$-FDG PET/CT)시행 후 즉시 다시 WB DXA 진행하였다. 결과는 PET/CT 전 후 DXA에서 WB-BMC, WB-BMD, TFM 그리고 LBM 등을 측정하였고 각 항목의 변화율을 산출하여 비교하였다. Non-Contrast Enhancement $^{18}F$-FDG PET/CT 전 후의 골밀도 및 체성분의 변화율은 WB-BMC, +2.4%; WB-BMD, +1.8%; TFM, -6.8%; LBM, +2.2%였고 각 항목의 변화는 통계적으로 유의한 차이가 없었다. Contrast Enhancement $^{18}F$-FDG PET/CT 전 후의 변화율은 WB-BMC, +13.7%; WB-BMD, +9.3%; TFM, -34.1%; LBM, +13.6%였고 Contrast Enhancement $^{18}F$-FDG PET/CT 전과 후의 골밀도 및 체성분 측정치의 변화는 통계적으로 유의하였다. 본 연구에서 Non-Contrast Enhancement $^{18}F$ PET/CT 후에는 DXA 시행은 결과에 영향이 없어 가능할 것이라 생각되어지나 Contrast Enhancement $^{18}F$-FDG PET/CT검사 후에 시행한 DXA 검사의 결과는 신뢰도가 감소될 것으로 사료된다.

  • PDF

타 인종에 있어 체질과 체성분의 상관성에 관한 연구 (Association between Sasang Constitutions and Body Composition in African-American, Asian, and Caucasian Race Groups)

  • 송미연;;김재희;지상은
    • 사상체질의학회지
    • /
    • 제15권2호
    • /
    • pp.124-128
    • /
    • 2003
  • Background: Sasang Constitutional Medicine (SCM) is a component of Korean traditional medicine that classifies humans into four categories, according to their constitution (Taeyangin, Taeumin, Soyangin and Soeumin). We are unaware of previous assessments of SCM in non-Asian race groups. Objectives: To quantify body composition components in three race groups and to determine whether SCM has an independent effect on body composition components. Design: A cross-sectional evaluation of 76 adults (28 Caucasian, 21 African-American, 27 Asian). Body composition was estimated using dual energy x-ray absorptiometry. Results: SCM component had a significant effect on weight, fat, and lean mass regardless of race group (p <0.001).

  • PDF

식이단백질량이 성장기 흰쥐가 골밀도에 대한 칼슘효율에 미치는 영향 (Effect of Dietary Protein Level on Ca Efficiency in Bone Mineral Density in Growing Rats)

  • 정소형
    • Journal of Nutrition and Health
    • /
    • 제28권9호
    • /
    • pp.817-824
    • /
    • 1995
  • This study was performed to evaluate the effect of dietary protein level on Ca efficiency in bone mineral density in growing male rats. Twenty male rate were divided into two groups. The rats in one group were fed on casein 20% diet as control group and the others were fed on casein 40% diet as protein group. All rats were fed on experimental diet and deionized water ad libitum for 9 weeks. The total body, spine and femur bone mineral density and bone mineral content were measured using dual energy-x ray absorptiometry. Urinary calcium, phosphate, pyridinoline and creatinine, serum calcium, phosphate, total protein, albumin, alkaline phosphatase(ALP) and osteocalcin were measured. Urinary Ca excretion, pyridinoline and crosslinks value and serum ALP content seem to be increased in high protein group. It appears that the growing rats in high protein group had a higher bone resprption and bone formation than those in control group. Animal fad a high protein diet had a siginficantly higher Ca efficiency in BMD, BMC of total body, spine and femur. The results of this show that increasing of dietary protein level (40%) is beneficial of improvement of Ca efficiency during growing period.

  • PDF

PROPERTIES OF THE CRYSTALLINE POLYIMIDE FILM DEPOSITED BY IONIZED CLUSTER BEAM

  • Whang, Chung-Nam
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 1992년도 추계학술발표강연 및 논문개요집
    • /
    • pp.6-6
    • /
    • 1992
  • Ionized cluster beam deposition (ICBD) technique has been employed to fabricate high-purity crystalline polyimide (PI) film. The pyromellitic dianhydride (PMDA) and oxydianiline (ODA) were deposited using dual ICB sources, Fourier trans forminfraredspectroscopy (FT-IR), X-ray photoemission spectroscopy (XPS), and Transmission electron microscopy (TEM)study show that the bulk and surface chemical properties and the crystalline structure are very sensitive to the ICBD conditions such as cluster ion acceleration voltage and ionization voltage, At optimum ICBD conditions, the PI films have a maximum imidization, negligible impurities(∼1% isoimide), and a good crystalline structure probably due to the high surface migration energy and surface cleaning effect. These characteristics are superior to those of films deposited by other techniques such as colvent cast, vapowr deposition, or sputtering techniques.

  • PDF