• Title/Summary/Keyword: Dry surface

Search Result 2,010, Processing Time 0.036 seconds

Development of the Novel Dry and Wet Deposition Collector (새로운 건성 및 습성 침착 채취기의 개발)

  • 이병규;이채복
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.675-684
    • /
    • 2000
  • A novel dry and wet deposition collector, which can overcome the several problems such as water evaporation cartridge cracks and high costs founded in the previous collector systems, has been constructed. ENVI-18 SPE adsorption cartridge has been used to measure atmospheric deposition of polycylic aromatic hydrocarbons (PAHs). A surrogate surface, consisted of water and methanol, was filled in the dry deposition funnel to simulate dry deposition onto water surface. A water supply system in order to compensat evaporation of the surrogate surface was used and it was consisted of a piston pump, a tubing pump, a overflow tube and a chamber system. A novel water vaporizing system to supply water onto the wet SPE cartridge system with a constant flow rate was developed. The novel water vaporizing system, consisted of a vacuum pump, a water supply reserviour and tube and a mini space heater, could prevent the PAHs adsorption cartridge cracks occurred in the previous collector and effectively adsorb PAHs. The novel dry and wet deposition collector showed a good adsorption, desorption, and recovery rates of PAHs. By reducing the number of pumps used and employing polypyopylene (PP) instead of teflon as a material of collection funnel, the total construction costs were much reduced as compared with the previous dry and wet deposition collectors.

  • PDF

A Study Vertical Surface Discharge Characteristics of the Shape Change of the Solid Insulation with the Same Creepage Distance of Dry-Air (Dry-Air 중의 동일 연면거리를 가진 고체절연물의 형상 변화에 따른 수직연면방전 특성 연구)

  • Jeon, Jong-Cheul;Choi, Byung-Ju;Bae, Sung-woo;Lee, Kwang-Sik;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.72-78
    • /
    • 2016
  • In terms of power components which use environmentally-friendly dry air that can substitute SF6, there have been studies on the electrical properties of the solid insulation "spacer" for the purpose of securing dielectric strength as they become smaller. This study laminated solid insulation to keep the creeping distance the same in the dry air and investigated vertical surface discharge characteristics by shape. The three sheets of disk-type solid insulation(Bakelite) were laminated in a manner to keep the creeping distance the same. The lamination was categorized as follows: "Type A" in which the insulations with the same disk diameter were laminated; "Type B" in which the insulations whose middle disk diameter was large were laminated; and "Type C" in which the ones whose middle disk diameter was small were laminated. For a vertical surface discharge experiment, dry air was injected into the test chamber depending on the shape of the laminated solid insulation, and chamber pressure was adjusted in a range of 0.1-0.6MPa. As volume decreased, surface discharging voltage by unit volume increased. This was because of dielectric polarization according to the structural characteristics of the shape of lamination. The highest surface discharging voltage was found in "Type C."

Atmospheric Dry Deposition Characteristics of Nitrogen-containing Compounds into Juam Reservoir (주암호에 대한 질소화합물의 대기건식침적 특성)

  • Cheong Jang-Pyo;Jang Young-Hoan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.657-666
    • /
    • 2005
  • The objectives of this study were to investigate atmospheric dry deposition of inorganic nitrogen-containing compounds to waterbody. Target waterbody is Juam reservoir functioning as one of the major water supply sources in Chollanamdo. Nitrate and ammonium dry deposition fluxes were directly measured using dry deposition plate (DDP) covered with greased strips and a water surface sampler (WSS). The daytime average $NO_{3}^{-}\;and\;NH_{4}^{+}$ fluxes measured with DDP and WSS were $1.7\∼2.6$ times higher than those at nighttime. The seasonal average flux of $NH_{4}^{+}$ showed the highest value in summer. The daytime and nighttime average dry deposition fluxes of particulate phase Nitogen-containing Compounds ($1.13,\;0.80\;mg/m^{2}$ day) were much higher than those of gas phase compounds ($0.50,\;0.24\;mg/m^{2}$ day).

A Dry-patterned Cu(Mg) Alloy Film as a Gate Electrode in a Thin Film Transistor Liquid Crystal Displays (TFT- LCDs) (TFT-LCDs 게이트 전극에 적용한 Cu(Mg) 합금 박막의 건식식각)

  • Yang Heejung;Lee Jaegab
    • Korean Journal of Materials Research
    • /
    • v.14 no.1
    • /
    • pp.46-51
    • /
    • 2004
  • The annealing of a Cu(4.5at.% Mg)/$SiO_2$/Si structure in ambient $O_2$, at 10 mTorr, and $300-500^{\circ}C$, allows for the outdiffusion of the Mg to the Cu surface, forming a thin MgO (15 nm) layer on the surface. The surface MgO layer was patterned, and successfully served as a hard mask, for the subsequent dry etching of the underlying Mg-depleted Cu films using an $O_2$ plasma and hexafluoroacetylacetone [H(hfac)] chemistry. The resultant MgO/Cu structure, with a taper slope of about $30^{\circ}C$ shows the feasibility of the dry etching of Cu(Mg) alloy films using a surface MgO mask scheme. A dry-etched Cu(4.5at.% Mg) gate a-Si:H TFT has a field effect mobility of 0.86 $\textrm{cm}^2$/Vs, a subthreshold swing of 1.08 V/dec, and a threshold voltage of 5.7 V. A novel process for the dry etching of Cu(Mg) alloy films, which eliminates the use of a hard mask, such as Ti, and results in a reduction in the process steps is reported for the first time in this work.

A Study on the Pollution of Nonylphenol in Surface Sediment in Gwangyang Bay and Yeosu Sound (광양만과 여수해만의 표층퇴적물에서 Nonylphenol의 오염에 관한 연구)

  • Jo, Hyeon Seo;Kim, Yong Ok;Seol, Sun U
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.561-570
    • /
    • 2004
  • This study was carried out to survey the pollution of nonylphenol (NP) in surface sediments around Gwangyang bay and Yeosu sound. NP was suspected chemicals as endocrine disruption. Gwangyang bay is located on the mid south coast of Korea. It is a semi-closed bay which Yeosu petrochemical industrial complex, POSCO (Pohang Steel Company) and Gwangyang container harbor are there. The surface sediments were collected at 15 stations with gravity corer at October, 1999, February, May and August, 2000. Also, the stream and intertidal sediment were collected at 5 sites at August, 2000. Concentrations of NP in surface sediments were in the range of 6.89 to 202.70 ng/g dry wt.. Seasonal range (mean value) of NP is 13.98 to 30.48 (23.46) ng/g dry wt. at October, 10.35 to 54.91 (28.10) ng/g dry wt. at February, 29.05 to 202.70 (82.32) ng/g dry wt. at May and 6.98 to 83.40 (25.37) ng/g dry wt. at August. NP was seasonally fluctuated, and the highest mean value and range was detected at May, 2000. NP was highly distributed in the inner part of Gwangyang bay than Yeosu sound. Concentrations of NP in stream and intertidal sediments showed the highest value in downstream near Yeosu petrochemical industrial complex and Yondung stream. It suggests that the source of NP is industrial wastewater and municipal sewage.

Detergency of PET Film Having Various Surface Free Energy: Part I. Surface Tension of MAA Grafted PET Film (Polyethylene terephthalate 필름의 표면에너지 변화에 따른 세척성(제일보) Methacrylic acid 그라프트 PET 필름의 표면장력)

  • Chung Hae-Won;Kim Sung-Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.2 s.27
    • /
    • pp.217-223
    • /
    • 1988
  • This study is to examine the cleaningproof by dry cleaning runs and parts(shoulder, belly, butt) of garment leathers tanned chrome. This study is composed of three methods of test; color difference test, surface view by scanning electron micrographs, mechanical properties measurement by KES-FB system. The results obtained were as follows: 1. In stiffening of parts of sample, the belly is the best degree in smoothness, fullness, softness. But that of the butt have been found to be the worst degree and to be thick. 2. In fading of parts, the shoulder is an extreme case, but the belly is the best among three parts. 3. In dry cleaning runs, the view after 3 runs has been found to be the best result. 4. The stiffening after dry cleaning 1 run have been low grade, for the sample absorb much solvent of dry cleaning. And, the fading and the decoloration are to be worse after 5 runs. Because the leather surface is affected by dry cleaning runs.

  • PDF

Surface Discharge Characteristics Study on the Laminated Solid Insulator in Quasi-Uniform Electric Field with Dry Air

  • Min, Gyeong-Jun;Bae, Sungwoo;Kang, Byoung-Chil;Park, Won-Zoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.603-609
    • /
    • 2015
  • Dry air is an excellent alternative to $SF_6$ gas and is used as an insulation gas in Eco-friendly Gas Insulated Switchgears (EGISs), which has gained popularity in industry. Solid insulators in EGIS play an important role in electrical insulation. On the other hand, surface discharge can occur easily when solid insulators are used. This paper explored the surface discharge characteristics on the structure of three-layered laminated solid insulators to elevate the flashover voltage. A laminated solid insulator was inserted after the quasi-uniform electric field was formed in the test chamber. Dry air was then injected to set the internal pressure to 1 ~ 6 atm, and the AC voltage was applied. When identical solid insulators were stacked, the surface discharge characteristics were similar to those of a single solid insulator. On the other hand, the flashover voltage rose when the middle part was thicker and had lower permittivity than the top and bottom parts in the laminated solid insulator. Based on experimental results, when stacking a solid insulator in three layers, the middle part of the solid insulator should be at least four times as thick as the top and bottom parts and have lower permittivity than the others. In addition, the flashover voltage increased with increasing gas pressure on the surface of the laminated solid insulator due to the gas effect. This study may allow insulation design engineers to have useful information when using dry air for the insulation gas where the surface discharge can occur.

A Study on the Distributional Characteristic of Organic Matters on the Surface Sediments and Its Origin in Keogeum-sudo, Southern Part of Korean Peninsula (거금수도(居金水道) 표층퇴적물 중의 유기물 분포 및 기원에 관한 연구)

  • 윤양호
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 2000
  • The observations on the seasonal fluctuation and distributional characteristic of organic matters on surface sediments and its origin were carried out at the 25 stations in Keogeum-sudo, southern coast of Korean Peninsula from February to October in 1993. I made an analysis on the environmental factors for surface sediments such as temperature, ignition loss, chemical oxygen demand, pheopigment, total sulphide, water content, mud content in grain size, COD/IL ratio and COD/sulphide ratio. The results are as follows ; 1) The range of temperature on the surface sediments was between 6.2${\circ}C$ and 24.6${\circ}C$. The highest mean temperatuer of mud was 24.0${\circ}C$ in summer, the lowest 6.6${\circ}C$ in winter. 2) Ignition loss(IL) fluctuated between 1.2% in winter and 16.8% in spring, that is to say, the seasons of increasing in temperature were very high ignition loss. 3) Chemical oxygen demand(COD) showed the highest mean value of 20.52 mg/g dry in summer within the range of 15/46~32.78 mg/g dry, while showed the lowest of 5.79 mg/g dry in winter within the range of 7.4~17.39 mg/g dry. 4) Pheopigment concentrations showed the highest mean value of 4.85 $\mu\textrm{g}$/g dry in autumn within the range of 0.84~9.21 $\mu\textrm{g}$/g dry, while it did the lowest mean value of 1.97 $\mu\textrm{g}$/g dry in summer within the range of 0.23~4.83 $\mu\textrm{g}$/g dry. 5) Total sulphide (H2S) fluctuated between no detect(ND) in spring, and 2.43 mg/g dry in sutumn. The highest mean value was 0.68 mg/g dry in sutumn, the lowest was 0.16 mg/g dry in spring. 6) Water content(WC) and mud content in grain size showed the mean value of 43.2% within the range of 26.5~59.7% and 91.0% within the range of 57.8~99.2%, respectively. 7) By the analytical results on the source of organic matter, it had been dumped from the seaweed farms in Keogeum-sudo coastal waters.

  • PDF

Three dimensional deformation of dry-stored complete denture base at room temperature

  • Lim, Seo-Ryeon;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.296-303
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate whether there is any typical deformation pattern existing in complete denture when it was dried by using the 3D scanner and surface matching program. MATERIALS AND METHODS. A total of 28 denture bases were fabricated with heat curing acrylic resin (each 14 upper and lower denture bases), and 14 denture bases (each 7 upper and lower denture bases) were stored in the water bottle (water stored), and another 14 denture bases were stored in the air (dry stored). Each specimen was scanned at $1^{st}$ day after deflasking, $14^{th}$ day after deflasking, and $28^{th}$ day after deflasking, and digitalized. Three dimensional deformation patterns were acquired by comparison of the data within storage group using surface matching program. For evaluating differences between groups, these data were compared statisticallyusing Kruskal Wallis and Mann Whitney-U test (${\alpha}$=.05). RESULTS. When evaluating 3D deformation of denture base, obvious deformations were not found in maxillary and mandibular water storage group. However, in dry stored group, typical deformation pattern was detected as storage time passes. It occurred mostly in first two weeks. Major deformations were found in the bilateral posterior area in both maxillary and mandibular group. In maxillary dry stored group, a statistical significance was found. CONCLUSION. It was proved that in both upper and lower denture bases, dry storage caused more dimensional deformation than water storage with typical pattern.

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.